- Weather
- Temperature
- Laboratory
- Sound
- IAQ
- Electrical
- All Categories
Extech DCP60-220 600W Switching Power Supply (220V)
Item #:
EXT-DCP60-220
Brand:
Extech
Share this product:
DCP60-220 600W Switching Power Supply (220V) by Extech
High efficiency switching power supply with low ripple and noise is ideal for demanding laboratory applications. Remotely control power ON/OFF and Voltage/Current output.
Designed for Laboratory use but excellent for bench technicians, engineers, and educational facilities.
Features
- 60V/10A output
- Maximum current can be limited to 5A using front panel auxiliary output on the front panel (10A main output is on the back panel)
- Three user-defined Voltage and Current presets
- Dual action rotary encoder control with push knob for fine and coarse tuning Remote control for Output Voltage/Current and On/Off
- Complete with power cord
Output | |
Variable Voltage Output | 1 to 60VDC |
Variable Current Output | 0 to 10ADC |
Voltage Regulation | |
Load (10 to 100% Load) | 50mV |
Model DCP60 | Line (90 to 130VAC Variation): 20mV |
Model DCP60-220 | Line (170 to 264VAC Variation): 20mV |
Current Regulation | |
Load (10 to 90% rated voltage) | 100mA |
Model DCP60 | Line (90 to 130VAC Variation): 50mA |
Model DCP60-220 | Line (170 to 264VAC Variation: 50mA |
Ripple and Noise | |
Ripple and Noise (RMS) voltage | 5mV |
Ripple and Noise (P-P) voltage | 100mv |
Current Ripple and Noise (RMS) | 10mA |
Meter Type and Accuracy | |
Voltage Meter | 3-digit LED Display ±0.2% + 3 counts |
Current Meter | 3-digit LED Display ±0.2% + 3 counts |
Input | |
Input Voltage | Model DCP60: 90 to 130VAC 50/60Hz Model DCP60-220: 220 to 240CVAC 50/60Hz |
Fuse | 8A/250V 5x20mm (120V); 4A/250V 5x20mm (220V) |
Full Load Current | 6.2A (120V); 3.25A (220V) |
Installation category | CAT 2 |
Other | |
Efficiency | 89% |
Switching Frequency | 65 to 85 kHz (approx.) |
Tracking Over-Voltage Protections | O/P 1-5V: set voltage +2V O/P 5-20V: set voltage +3V O/P 20-60V: set voltage +4V |
Transient Response Time (50-100% load) | 1.5ms |
Power Factor Control | Power Factor correction >0.9 at optimal load |
Cooling method | Thermostatic control fan from zero to full speed |
Protections | Overload, Short Circuit by Constant Current, Output Tracking Over Voltage, and Over Temperature |
Operating %RH | 10 to 80% Relative Humidity |
Approvals | CE, EMC: EN 55011, 55022, LVD: EN 60950, 61010 |
Dimensions | 7.9 x 3.5 x 8.5" (200 x 90 x 215mm) |
Weight | 5.7lbs. (2.6 kg) |
Altitude | up to 6561 ft. (2000m) |
Pollution degree | 2 |