BL982411-0 ORP Mini Controller, 12VDC 0 - 1000 mV by Hanna Instruments

BL 982411 is an ORP mini controller for panel mounting, specially designed for swimming pools and spas. Thanks to its compact size, BL 982411 can be installed in small spaces. BL 982411 is the ideal solution for those who have always checked ORP manually. With it’s automatic dosing, this mini controller will significantly reduce maintenance time.

BL 982411 can be used with any ORP electrode with standard BNC connector. The instrument measures ORP in the 0 to 1000 mV range and shows the readings on the display. The status LED continuously indicates if the controller is in measurement, dosing or alarm mode.

BL 982411 is also provided with a relay for selecting the dosing direction, oxidizing or reducing.

Users can choose automatic or manual dosing mode with a switch on the front panel. Manual control is particularly useful during maintenance operations, because it permits operators to enable or disable the dosing relay according to need. The overtime control system advises users when the relay is active for too long, helping to prevent over-dosage.

  • Easy to handle
  • Fire retardant casing
  • Selectable overdose protection system
  • Splash resistant cover

Order Information:

BL 982411-0 (12 VDC) and BL 982411-1 ( 115/230V) are supplied with mounting brackets, transparent cover and instruction manual.

Range 0 to 1000 mV
Resolution 1 mV
Accuracy @ 25°C ±5 mV
Calibration manual, with CAL trimmer
Dosing Relay maximum 2A (fuse protected), 250 Vac, 30 VDC
Dosing Selection reducing or oxidizing, selectable on the back panel 
contact open
=reductant dosage=relay ON if measure > set point
contact close=oxidant dosage=relay ON if measure < set point
Setpoint adjustable from 0 to 1000 mV
Overtime adjustable, typically from 5 to approx. 30 minutes
Input Impedance 102 Ohm
Power Supply 0 = 12 Vdc Power Adapter (included)
Dimensions 79 x 49 x 95 mm (3.1 x 1.9 x 3.7’’)
Weight 200g (7.1 oz)