- All Products
- Shop by Brands
- BW Technologies
- BW Technologies
- BW Technologies Monitors
- Models
- BW Clip
- BW Clip4
- GasAlertClip Extreme
- GasAlert Extreme
- GasAlertMicroClip XT
- GasAlertMicroClip XL
- GasAlertMicroClip X3
- GasAlertQuattro
- GasAlertMax XT II
- GasAlertMicro 5 Series
- SamplerPak
- IntelliDox Docking System
- MicroDock II
- BW Ultra
- BW Solo
- Gas Monitors
- Gas Monitor Manufacturers
- BW Technologies
- Bacharach
- Biosystems
- Crowcon
- Gas Clip Technologies
- GfG Instruments
- GMI/Detcon
- Honeywell Analytics
- Industrial Scientific
- MSA
- RAE Instruments
- RKI Instruments
- Calibration Gas
- Combustion Analyzers
- Water Quality
- Reliability Instruments
- Refractometers
- HVAC
- Weather
- Temperature
- Laboratory
- Sound
- IAQ
- Electrical
- All Categories
Hanna pH Mini Controller with 4-20 mA Recorder Output, 12VDC 0.00 - 14.00 pH - BL931700-0
Item #:
BL931700-0
Brand:
Hanna Instruments
Share this product:
BL931700-0 pH Mini Controller with 4-20 mA Recorder Output, 12VDC 0.00 - 14.00 pH by Hanna Instruments
The BL 931700 mini pH controller has been designed for easy, affordable installation in tight spaces to perform simple yet effective process control. Thanks to its compact size, the BL 931700 mini pH controller can be installed right next to tanks or vats.
This versatile controller is ideal for a wide variety of applications, such as textiles, papers, photographic solutions, plating baths, chemicals and water treatment.This BL 931700 is provided with a selectable set point for acid or basic dosage.
Measurements are directly taken from a pH electrode in the range from 0 to 14 with a 0.01 pH resolution. Accuracy is ensured by two point calibration, performed manually through trimmers on the front panel.
Users can choose automatic or manual dosing mode with a switch on the front panel. Manual control is particularly useful during maintenance operations, because it permits operators to enable or disable the dosing relay according to need. The overtime control system advises users when the relay is active for too long, helping to prevent overdosing.
In addition, this model features a 4-20 mA analog output for recorder connection.
- It's easy to handle
- Fire retardant casing
- Selectable overdose protection system
- Splash resistant cover
Order Information:
BL 931700-0 (12 VDC) and BL 931700-1 ( 115/230V) are supplied with mounting brackets, transparent cover and instruction manual.
Range | 0.00 to 14.00 pH |
Resolution | 0.01 pH |
Accuracy @ 25°C | ±0.02 pH |
Calibration | manual, 2 point, with offset and slope trimmers |
Dosing Relay | max 2A (fuse protected), 250 Vac, 30 Vdc |
Dosing Selection | acid or alkaline contact open=acid dosage=relay ON if measurement > set point contact close=alkaline dosage=relay ON if measurement < set point |
Setpoint | adjustable from 0.00 to 14.00 pH |
Overtime | adjustable, typically from 5 to approx. 30 minutes |
Recorder Output | 4-20 mA, accuracy ±0.20 mA, 500 Ohm max load |
Input Impedance | 102 Ohm |
Power Supply | 0 = 12 Vdc Power Adapter (included) |
Dimensions | 79 x 49 x 95 mm (3.1 x 1.9 x 3.7’’) |
Weight | 200g (7.1 oz) |