- All Products
- Shop by Brands
- BW Technologies
- BW Technologies
- BW Technologies Monitors
- Models
- BW Clip
- BW Clip4
- GasAlertClip Extreme
- GasAlert Extreme
- GasAlertMicroClip XT
- GasAlertMicroClip XL
- GasAlertMicroClip X3
- GasAlertQuattro
- GasAlertMax XT II
- GasAlertMicro 5 Series
- SamplerPak
- IntelliDox Docking System
- MicroDock II
- BW Ultra
- BW Solo
- Gas Monitors
- Gas Monitor Manufacturers
- BW Technologies
- Bacharach
- Biosystems
- Crowcon
- Gas Clip Technologies
- GfG Instruments
- GMI/Detcon
- Honeywell Analytics
- Industrial Scientific
- MSA
- RAE Instruments
- RKI Instruments
- Calibration Gas
- Combustion Analyzers
- Water Quality
- Reliability Instruments
- Refractometers
- HVAC
- Weather
- Temperature
- Laboratory
- Sound
- IAQ
- Electrical
- All Categories
Fieldpiece 4 Port Wireless Digital Manifold with Micron Gauge - SMAN4
Item #:
FP-SMAN4
Brand:
Fieldpiece
Share this product:
SMAN4 4 Port Wireless Digital Manifold with Micron Gauge by Fieldpiece
The SMAN4 is a 4-port, wireless digital manifold with a large 3/8" port for faster evacuations and recovery. With four ports and a built-in vacuum gauge, HVACR pros can now evacuate a system, pull a vacuum, add refrigerant and dial in the charge at one time, without having to hook and unhook any hoses.
To make things even easier, the SMAN4 wirelessly receives live indoor wet bulb and outdoor dry bulb, then automatically calculates real-time target superheat, and displays both the target superheat and actual superheat on the large, backlit display. Plus, the SMAN4 digital manifold displays actual subcooling and superheat simultaneously.
The SMAN4 manifold also wirelessly sends six measurements (indoor wet bulb, outdoor dry bulb, suction line temperature, suction line pressure, liquid line temperature, and liquid line pressure) to the Fieldpiece HVAC Guide System Analyzer, model HG3. The HG3 then combines the SMAN4 wireless measurements with wireless airflow measurements for full system analysis -- in real-time!
Wireless Measurements
- Sends all measurements to HG3 for full system analysis
- Receives indoor wet bulb and outdoor dry bulb wirelessly for live charging (if in wireless mode, both indoor and outdoor measurements must be sent wirelessly to the SMAN4)
Large 4th Port
- 3/8" port and 3/8' bore throughout for faster evacuations
Target Superheat
- Automatically calculated from measurements taken
- No guesswork or manual calculations
Superheat and Subcooling
- Calculated and displayed simultaneously
Multiline Backlit Display
- Resistant to extreme temperatures
- Viewable up to 20' away
K-type Thermocouples
- Fast reacting
- Accurate temperatures
- Displays actual temperatures
Field Calibration
- Quck and easy
- Temperature
- 2-point pressure
Micron Gauge Alarm
- Alarm sound when chosen micron level is reached
- 50 to 9,999 resolution
Vacuum Stopwatch
- Tracks time vacuum pump's been working
- Length of time can indicate hidden issues
39 Refrigerants
- Built-in P-T charts
Carrying Case
- Easy to hang when not using
- Leave hoses& clamps attached
Includes
- 4-port Wireless Manifold - SMAN4
- Pipe Clamp Thermocouples (2) - ATC1
- Wet Bulb Thermocouple - ATWB1
- Dry Bulb Thermocouple - ATA1
- Padded Drawstring Pouch - ANC10
- Operator's Manual
General Specification | |
Mini-USB port | For updating to newer versions of firmware |
Display size | 5 inches (diagonal) |
Backlight | Blue (On for 1 minute unless turned off manually) |
Battery | 6 x AA (Battery life below based on alkaline type) |
Battery life | Approx. 135 hours (without backlight and wireless) |
Low battery indication | battery symbol is displayed when the battery voltage drops below the operating level |
Auto Shut off | 30 minutes of inactivity when APO is activated |
Over range | "OL" or "-OL" is displayed |
Operating environment | 32°F to 122°F (0°C to 50°C) at <75% RH |
Storage temperature | 4°F to 140°F (-20°C to 60°C), 0 to 80% RH (with battery removed) |
Temperature coefficient | 0.1 x (specified accuracy) per °C (0°C to 18°C, 28°C to 50°C), per 0.6°F (32°F to 64°F, 82°F to 122°F |
Weight | 4.03 lbs (1.83 kg) |
Pressure | |
Sensor type | Absolute pressure sensors |
Connector Type | Standard 1/4" and 3/8" NPT male flare fitting |
Range | 29" HgV to 580psig (English), 74 cmHgV to 0 to 4000KPa (Metric), 4.000MPa (Metric), and 40.00bar (Metric) |
Resolution | 0.1 psi/inHg; 1 kPa/cmHg; 0.001MPa; 0.01bar |
Accuracy | 29" HgV to 0" HgV: ±0.2" HgV 74 cmHgV to 0 cmHgV: ±1 cmHgV 0 to 200 Psig: ±1 Psi; 0 to 1378 KPa: ±7 KPa; 0 to 1.378MPa: ±0.007MPa; 0 to 13.78 bar ±0.07 bar 200 to 580 Psig: ±0.3%+1 Psi; 1378 to 4000KPa: ±0.3%+7 Kpa; 1.378 to 4.000MPa: ±0.3%+0.007MPa; 13.78 to 40.00bar: ±0.3%+0.07bar |
Maximum overload pressure | 800 psig |
Units | Psig, kPa, MPa, bar, inHg, and cmHg |
Microns for Vacuum (SMAN3 only) | |
Connector Type | Standard 1/4" and 3/8" NPT male flare fitting |
Range | 50 to 9999 microns of mercury |
Resolution | 1 micron (50 to 2000 microns), 250 microns (2001 to 5000 microns), 500 microns (5001 to 8000 microns), 1000 microns (8001 to 9999 microns) |
Accuracy | ±10% or ±10 microns, whichever is greater (50 to 1000 microns) |
Maximum Overload pressure | 580 psig |
Units | Microns of mercury |
Temperature | |
Sensor type | K-Type thermocouple |
Range | -95°F to 999.9°F (-70°C to 537.0°C) |
Resolution | 0.1°F/°C |
Accuracy | ±(1.0°F) -95°F to 199.9°F; ±(0.5°C) -70°C to 93°C ±(2.0°F) 200°F to 999.9°F; ±(1.0°C) 93°C to 537.0°C |
Wireless | |
Wireless range | 1 to 100 feet (30m) |
Initial wireless sync range | More than 1 foot and less than 10 feet |