- All Products
- Shop by Brands
- BW Technologies
- BW Technologies
- BW Technologies Monitors
- Models
- BW Clip
- BW Clip4
- GasAlertClip Extreme
- GasAlert Extreme
- GasAlertMicroClip XT
- GasAlertMicroClip XL
- GasAlertMicroClip X3
- GasAlertQuattro
- GasAlertMax XT II
- GasAlertMicro 5 Series
- SamplerPak
- IntelliDox Docking System
- MicroDock II
- BW Ultra
- BW Solo
- Gas Monitors
- Gas Monitor Manufacturers
- BW Technologies
- Bacharach
- Biosystems
- Crowcon
- Gas Clip Technologies
- GfG Instruments
- GMI/Detcon
- Honeywell Analytics
- Industrial Scientific
- MSA
- RAE Instruments
- RKI Instruments
- Calibration Gas
- Combustion Analyzers
- Water Quality
- Reliability Instruments
- Refractometers
- HVAC
- Weather
- Temperature
- Laboratory
- Sound
- IAQ
- Electrical
- All Categories
Fieldpiece Dual Display Mini Clamp Meter - SC53
Item #:
FP-SC53
Brand:
Fieldpiece
Share this product:
SC53 Dual Display Mini Clamp Meter by Fieldpiece
Read amps and volts at the same time with the Dual-Display Mini Clamp Meter with Temperature, model SC53. In addition to having a dedicated display for reading amps, you can measure any of the other ranges on the meter dial simultaneously. The SC53 is compact measuring only about 8-inches, easy to use and includes many of the ranges you use everyday during HVACR field service. Many instructors recommend the SC53 as a starter meter while seasoned veterans call it a little HVAC workhorse. Temperature and capacitance, built-in safety features like non-contact voltage and amp or dial hold, make this meter a solid choice for the work you do in the field.
- Dual Display
- Temperature up to 400 degrees F
- Capacitance (MFD)
- 400AAC
- Non-contact Voltage
- Hold
- Backlight
- Volts AC
- Volts DC
- Resistance (Ohms)
- Continuity
- Rugged ABS case
- Ergonomic shape
- Auto power-off
- Amps and volts simultaneously
- Works with Fieldpiece Accessory Heads
Includes
- Dual-Display Mini Clamp Meter with Temperature - SC53
- Vinyl Test Leads
- Mini Clamp-On Meter Case - ANC4
- Three 3V lithium-ion CR2032 Batteries (installed)
- Operator's Manual
General Specification | |
Display | 33/4 digit liquid crystal (LCD) with a maximum reading of 3999 |
Overrange | "OL" or “-OL” mark indication. |
Auto power off | 10 minutes. |
Operating environment | 32 to 122°F (0 to 50°C), at <70% R.H. |
Storage temperature | -4 to 140°F (-20 to 60°C), @ <80% R.H. with batteries removed. |
Accuracy | Specifications good in ambient conditions of 74°F ±8°F (23°C ±4°C), <75% relative humidity. |
Temperature coefficient | 0.1×(specified accuracy) per °F/°C; 32 to 66°F (0 to 19°C); 82 to 122°F(28 to 50°C). Altitude: 6561.7 feet (2000m). |
Jaw opening capability | 30mm (diameter) conductor |
Power | Three lithium-ion CR2032 3V batteries. |
Battery life | 100 hours typical for lithium-ion on AAC (top display),75 hours typical for lithium-ion on dial functions (bottom display). |
Accessories | One pair vinyl test leads, ATB1 k-type thermocouple (SC53), (3) 3V CR2032 batteries (installed), ANC4 carrying case, and operating instructions. |
Safety | IEC/EN 61010-1 (UL61010-1) CATIII 600V and IEC/EN 61010-2-032 (UL61010-2-032) CATIII 300V, class II and pollution degree 2 indoor use comply with CE, C-tick certified. |
DC Volts | |
Ranges | 4V, 40V, 400V, 600V |
Resolution | 1mV |
Accuracy | ±(0.5% rdg + 2 dgts) |
Input impedance | 4V: 10MΩ 40V~600V: 9.1MΩ |
AC Volts (50Hz - 500Hz) | |
Ranges | : 4V, 40V, 400V, 600V |
Resolution | 1mV |
Accuracy | ±(1.2% rdg + 5 dgts), ±(1.5% rdg + 5 dgts) on 600V range |
Input impedance | 4V: 10MΩ 40V~600V: 9.1MΩ |
Minimum test time for stable reading | 2 seconds |
Resistance | |
Ranges | 400Ω, 4kΩ, 40kΩ, 400kΩ, 4MΩ, 40MΩ |
Resolution | 0.1Ω |
Accuracy | ±(1.0% rdg + 4 dgts) on 400Ω to 400kΩ ranges ±(1.5% rdg + 4 dgts) on 4MΩ range ±(3.0% rdg + 5 dgts) on 40MΩ range |
Open circuit volts | -0.45VDC typical, (-1.2VDC on 400Ω range) |
Minimum test time for stable reading | 2 seconds |
AC Current (50Hz - 60Hz) | |
Ranges | 40A, 400A |
Resolution | 0.01A |
Accuracy | ±(2.0% rdg + 6 dgts) |
DC Current (SC52) | |
Ranges | 400μA, 4000μA |
Resolution | 0.1μA |
Accuracy | ±(1.0% rdg + 2 dgts) |
Voltage burden | 1V (8V on 4000μA range) |
Capacitance (SC53) | |
Range | 4μF, 40μF, 400μF, 4mF 4.000mF = 4000μF |
Resolution | 1.0nF |
Accuracy | ±(3% rdg + 10 dgts) on 4μF ±(3% rdg + 5 dgts) on 40μF to 400μF ±(5% rdg + 20 dgts) on 4mF (4000μF) |
Minimum input range | >100nF |
Safety | "dsc" symbol on LCD indicates that the capacitor must be discharged before testing |
Continuity | |
Range | 400Ω |
Resolution | 1Ω |
Audible indication | Less than 25Ω |
Response time | 500ms |
Diode Test (SC52) | |
Test current | 1.2mA (approximate) |
Accuracy | ±(3.0% rdg + 3 dgts) |
Resolution | 10mV |
Audible indication | Less than 0.25V |
Open circuit volts | 3.0VDC typical |
Temperature (SC53) | |
Range | -30 to 400°F (-34 to 204°C) |
Resolution | 0.1° |
Accuracy | ±1°F (32 to 120°F); ±0.5°C (0 to 49°C), ±1% + 1.5°F (-4 to 400°F); ±1% + 1°C (-20 to 204°C), ±2% + 4°F (-30 to -4°F); ±2% + 2°C (-34 to -20°C) |
Sensor type | K-type thermocouple |