- All Products
- Shop by Brands
- BW Technologies
- BW Technologies
- BW Technologies Monitors
- Models
- BW Clip
- BW Clip4
- GasAlertClip Extreme
- GasAlert Extreme
- GasAlertMicroClip XT
- GasAlertMicroClip XL
- GasAlertMicroClip X3
- GasAlertQuattro
- GasAlertMax XT II
- GasAlertMicro 5 Series
- SamplerPak
- IntelliDox Docking System
- MicroDock II
- BW Ultra
- BW Solo
- Gas Monitors
- Gas Monitor Manufacturers
- BW Technologies
- Bacharach
- Biosystems
- Crowcon
- Gas Clip Technologies
- GfG Instruments
- GMI/Detcon
- Honeywell Analytics
- Industrial Scientific
- MSA
- RAE Instruments
- RKI Instruments
- Calibration Gas
- Combustion Analyzers
- Water Quality
- Reliability Instruments
- Refractometers
- HVAC
- Weather
- Temperature
- Laboratory
- Sound
- IAQ
- Electrical
- All Categories
Fieldpiece Dual Display Swivel-Head Clamp Meter - SC55
Item #:
FP-SC55
Brand:
Fieldpiece
Share this product:
SC55 Dual Display Swivel-Head Clamp Meter by Fieldpiece
The SC55 Swivel-Head Clamp Meter is specifically designed for HVACR professionals and contains all the functions most relevant to the job. Packed with 13 different test parameters the SC55 clamp meter offers more features and functions than any other meter of its kind on the market. Plus the full 180º swivel head allows you to easily see the display at any angle.
Perfect for those hard to reach wires, the SC55 Swivel-Head Clamp Meter also boasts a rugged design to withstand harsh conditions, has the precision and reliability that Fieldpiece is known for, and is compatible with all Fieldpiece Accessory Heads via your test leads.
- 180° Swivel Head Clamp to easily view your results at any angle
- Dual Display to easily view multiple measurements at one time
- Rugged Construction to withstand harsh conditions
- Auto Power Off to preserve your battery life when clamp isn't in use
- Non-Contact Voltage warning via audio and visual alarms
- Easy Field Calibration with convenient pot location to quickly calibrate K-type thermocouples
- Auto or Manual Ranging button to conveniently toggle between ranges
- Hold Function to keep data as long as necessary
- Select Button to swiftly toggle through measurement options
- Frequency Measurement without test leads
- Constant Battery Status so you don't run out of batteries in the middle of a job
Includes
- SC55 - Swivel Head Clamp Meter
- ADLS2 - Deluxe Silicone Test Leads
- ASA2 - Alligator Clip Lead Extensions
- ATB1 - K-type Thermocouple
- ANC7 - Large Single Meter Case
- Velcro Strap
General Specification | |
Display | 5000 count dual display with backlight |
Overrange | (OL) or (-OL) is displayed |
Measurement rate | 3.3 times per second, nominal |
Zero | Automatic |
Operating environment | 32°F to 122°F (0°C to 50°C) at <70% relative humidity |
Storage temperature | -4°F to 140°F (-20°C to 60°C), 0 to 80% RH (with battery removed) |
Accuracy | Stated accuracy @ 73°F±9°F (23°C±5°C), <75%RH |
Temperature coefficient | 0.1 x (specifi ed accuracy) per °C [0°C to 19°C (32°F to 66°F), 28°C to 50° C(82°F to 122°F)] |
APO (Auto Power Off) | Approx. 30 minutes |
Power | Single standard 9-volt battery, NEDA 1604, JIS 006P, IEC 6F22 |
Battery life | 200 hours typical alkaline (SC55); 100 hours typical alkaline (SC56) |
Low battery indication | Battery icon blinks and "LO.bt" is displayed when the battery voltage drops below the operating level |
Dimensions | 258.3mm(H) x 71.2mm(W) x 42.7mm(D) |
Weight | Approx. 278g including battery |
Overload protection | 600 VDC or 600VAC rms unless otherwise stated |
Test leads | Use the test leads that are supplied with the meter or UL listed test leads rated CATIII 600V or above. |
Temperature (°F/°C) | |
Range | -30°F to 932°F, (-35°C to 500°C) |
Resolution | 0.1° |
Accuracy | ±(1°F) 32°F to 120°F, ±(1°C) 0°C to 49°C ±(1%+2°F) 32°F to 572°F, ±(1%+1°C) 0°C to 300°C ±(2%+6°F) -30°F to 32°F, ±(2%+3°C) -35°C to 0°C ±(2%+6°F) 572°F to 932°F, ±(2%+3°C) 300°C to 500°C |
Sensor type | K-type thermocouple |
Overload protection | 30 VDC or 30VAC rms |
Non Contact Voltage (NCV) | |
AC Voltage Detection Range | 24VAC to 600VAC (50-60Hz) |
Voltage AC (VAC) (50Hz-500Hz) | |
Ranges | 500mV, 5V, 50V, 500V, 600V |
Resolution | 0.1mV |
Accuracy | ±(1.2% + 8) 500mV range (50-60Hz) ±(1.2%+8), 5V, 50V, 500V; ±(1.5% + 8) 600V range |
True RMS | model SC56 only |
Crest factor | ≤ 3 |
Input impedance | >100MΩ (500mV), 10MΩ (5V), 9.1MΩ (50V-600V) |
MicroAmps DC (μADC) | |
Ranges | 500μA |
Resolution | 0.1μA |
Accuracy | ±(1.0% + 2) |
Voltage burden | 1V |
Overload Protection | 600VDC or 600VAC rms |
Frequency (Hz) through Leads | |
Ranges | 500Hz, 5kHz, 50kHz, 500kHz, 1MHz |
Resolution | 0.1Hz |
Accuracy | ±(0.1% + 5) |
Sensitivity | 10Hz to 1MHz: >3.5Vrms |
Duty Cycle (%) | |
Ranges | 5%-95% (40Hz to 20kHz) |
PW | >10μs |
Resolution | 0.1% |
Accuracy (5V logic) | ±(2% + 10) |
Capacitance (MFD) | |
Ranges | 5μF, 50μF, 500μF, 5mF |
Resolution | 1nF |
Accuracy | ±(3% + 15) 5μF, ±(3% + 5) 50μF to 500μF, ±(5% + 20) 5mF |
Overload Protection | 600VDC or 600VAC rms |
Voltage DC (VDC) | |
Ranges | 500mV, 5V, 50V, 500V, 600V |
Resolution | 0.1mV |
Accuracy | ±(0.5% + 2) |
Input impedance | >100MΩ (500mV), 10MΩ (5V), 9.1MΩ (50V-600V) |
Resistance (Ω) | |
Ranges | 500Ω, 5kΩ, 50kΩ, 500kΩ, 5MΩ, 50MΩ |
Resolution | 0.1Ω |
Accuracy | ±(1.0% + 5) 500Ω to 500kΩ, ±(1.5% + 5) 5MΩ, ±(3.0% + 5) 50MΩ |
Overload Protection | 600VDC/VAC rms |
Continuity | |
Range | 500Ω |
Resolution | 0.1Ω |
Response time | 100ms |
Audible beep | <30Ω |
Overload Protection | 600VDC/VACrms |
Diode Test | |
Test current | 0.8mA (Approx.) |
Accuracy | ±(1.5% + 5) |
Overload Protection | 600VDC/VACrms |