1-866-4 JJSTECH(1-866-455-7832)

Fieldpiece True RMS Mini Clamp Meter - SC46

Item #:
FP-SC46
Brand:
Fieldpiece
Fieldpiece True RMS Mini Clamp Meter - SC46
$116.00
Qty

Discontinued

Send This Page to a Friend

Ask an Expert

Our tech experts are ready to help!

1-866-4 JJSTECH (1-866-455-7832)

Email Us
Share this product:
Fieldpiece True RMS Mini Clamp Meter - SC46

Fieldpiece True RMS Mini Clamp Meter - SC46

$116.00

Discontinued


SC46 True RMS Mini Clamp Meter by Fieldpiece

The SC46 True RMS Mini Clamp Meter with Temperature and Backlight packs the biggest punch in the SC40 series. With features that rival many full-sized clamp meters, this auto ranging DMM packs a ton of functions into a compact, easy to handle shape. It includes temperature and capacitance as well as a bright green backlight and True RMS for more accurate readings on non-sinusoidal AC waveforms. It also packs in most of the other HVACR ranges you use everyday. Some technicians use the SC46 as their everyday DMM, others as a back-up or second meter to get more testing done in less time. This mini-clamp was deigned to make your job easier, safer, and faster no matter where you choose to rank it in your bag.

  • True RMS
  • Temperature
  • Capacitance (MFD)
  • 400AAC
  • Non-contact Voltage
  • Hold
  • Backlight
  • Volts AC
  • Volts DC
  • Resistance (Ohms)
  • Continuity
  • Rugged ABS case
  • Ergonomic shape
  • Auto power-off
  • Works with any accessory head
  • Autoranging

Includes

  • True RMS Mini Clamp Meter with Temperature and Backlight - SC46
  • Vinyl Test Leads
  • One (1) Wrap-Tab K-type Thermocouple - ATB1
  • Mini Clamp-On Meter Case - ANC4
  • Two 1.5V "AAA" Batteries (installed)
  • Operator's Manual
General Specification
Display 33/4 digit liquid crystal (LCD) with a maximum reading of 3999
Range Manual ranging mode (SC44 & SC45), hold button for 2 seconds to return to autoranging mode.
Overrange "OL" or "-OL" mark indication.
Auto power off 10 minutes.
Operating environment 32 to 122°F (0 to 50°C), at <70% R.H.
Storage temperature -4 to 140°F (-20 to 60°C), @ <80% R.H. with batteries removed.
Accuracy Specifications good in ambient conditions of 74°F ±8°F (23°C ±4°C), <75% relative humidity
Temperature coefficient 0.1×(specified accuracy) per °F/°C; 32 to 66°F (0 to 19°C); 82 to 122°F(28 to 50°C).
Altitude 6561.7 feet (2000m).
Power Two AAA 1.5V batteries
Battery life 400 hours typical with alkaline (SC44),
300 hours typical with alkaline (SC45),
200 hours typical with alkaline (SC46).
Accessories One pair test leads, (2) 1.5V AAA batteries (installed), carrying case and operating instructions.
Safety Designed to meet IEC61010-1 (EN61010-1) and IEC61010-2-032 (EN61010-2-032), CATIII 300V, class II and pollution degree 2 indoor use comply with CE, C-tick certified.
Temperature (SC45 and SC46)
Range -30 to 400°F (-34 to 204°C)
Resolution 0.1°
Accuracy ±1°F (32 to 120°F); ±0.5°C (0 to 49°C),
±1% + 1.5°F (-4 to 400°F); ±1% + 1°C (-20 to 204°C),
±2% + 4°F (-30 to -4°F); ±2% + 2°C (-34 to -20°C)
Sensor type K-type thermocouple
Capacitance (SC45 and SC46)
Range 4μF, 40μF, 400μF, 4mF
4.000mF = 4000μF
Resolution 1.0nF
Accuracy ±(3% rdg + 10 dgts) on 4μF
±(3% rdg + 5 dgts) on 40μF to 400μF
±(5% rdg + 20 dgts) on 4mF (4000μF)
Minimum input range >100nF
Safety "dsc" symbol on LCD indicates that the capacitor must be discharged before testing.
DC volts
Ranges 400mV (except SC46), 4V, 40V, 400V, 600V
Resolution 0.1mV (1mV for SC46)
Accuracy ±(0.5% rdg + 2 dgt)
Input impedance 400mV > 100MΩ
4V = 10MΩ
40V~600V = 9.1MΩ
Transient protection 6kV for 10μ sec
AC volts (50Hz - 500Hz)
True RMS SC46 only, Crest factor: ≤3
Ranges 4V, 40V, 400V, 600V
Resolution 1mV
Accuracy(SC44, SC45) ±(1.2% rdg + 5 dgts), ±(1.5% rdg + 5 dgts) on 600V range
Accuracy(SC46) ±(1.2% rdg + 8 dgts), ±(1.5% rdg + 8 dgts) on 600V range
Input impedance 4V = 10MΩ
40V~600V = 9.1MΩ
Resistance
Ranges 400Ω, 4kΩ, 40kΩ, 400kΩ, 4MΩ, 40MΩ
Resolution 0.1Ω (1Ω for SC45, SC46)
Accuracy ±(1.0% rdg + 4 dgts) on 400Ω to 400kΩ ranges
±(1.5% rdg + 4 dgts) on 4MΩ range
±(3.0% rdg + 5 dgts) on 40MΩ range
Open circuit volts -0.45VDC typical, (-1.2VDC on 400Ω range)
AC Current (50Hz - 60Hz)
True RMS SC46 only
Crest factor ≤3
Ranges 40A, 400A
Resolution 0.01A
Accuracy(SC44, SC45) ±(2.0% rdg + 6 dgts)
Accuracy(SC46) ±(2.0% rdg + 10 dgts)
Continuity
Audible indication Less than 25Ω
Response time 500ms
Diode Test
Test current 1.2mA (approximate)
Accuracy ±(3.0% rdg + 3 dgts)
Resolution 10mV
Audible indication Less than 0.25V
Open circuit volts 3.0VDC typical

Questions & Answers