1-866-4 JJSTECH(1-866-455-7832)

Fieldpiece 3 Port Digital Manifold with Micron Gauge - SMAN3

Item #:
FP-SMAN3
Brand:
Fieldpiece
Fieldpiece 3 Port Digital Manifold with Micron Gauge - SMAN3
$435.00
Qty

Discontinued

Send This Page to a Friend

Ask an Expert

Our tech experts are ready to help!

1-866-4 JJSTECH (1-866-455-7832)

Email Us
Share this product:
Fieldpiece 3 Port Digital Manifold with Micron Gauge - SMAN3

Fieldpiece 3 Port Digital Manifold with Micron Gauge - SMAN3

$435.00

Discontinued


SMAN3 3 Port Digital Manifold with Micron Gauge by Fieldpiece

The SMAN3 automatically calculates target superheat, so you don't have to worry about guesswork or manual calculations. WIth the SMAN3 you also get a built-in micron gauge with resolution from 50 to 9,999. On top of that, the SMAN3's exclusive micron alarm allows you to set the alarm to a chosen micron level, and when the vacuum reaches that level, the alarm will sound, freeing you up to keep working when pulling a vacuum.

Plus the SMAN series are the only manifolds with the ability to perform a linear adjustment of the pressure sensors based on refrigerant type, temperature, and pressure, and it's so easy, you can do it right in the field.

By combining new technology with an intuitive, easy-to-use interface, the SMAN3 makes it easy for you to quickly maximize the efficiency of any A/C or refrigeration unit. And because they're built by the HVACR industry's leading innovator, you know it's packed with the features you want.

Target Superheat

  • Automatically calculated from measurements taken
  • No guesswork or manual calculations

Superheat and Subcooling

  • Calculated and displayed simultaneously

Multiline Backlit Display

  • Resistant to extreme temperatures
  • Viewable up to 20' away

K-type Thermocouples

  • Fast reacting
  • Accurate temperatures
  • Displays actual temperatures

Field Calibration

  • Quck and easy
  • Temperature
  • 2-point pressure

Micron Gauge Alarm

  • Alarm sound when chosen micron level is reached
  • 50 to 9,999 resolution

Vacuum Stopwatch

  • Tracks time vacuum pump's been working
  • Length of time can indicate hidden issues

Long Battery Life

  • 500 hours on SMAN2
  • 135 hours on SMAN3
  • Constant battery status
  • Auto power off

39 Refrigerants

  • Built-in P-T charts

Carrying Case

  • Easy to hang when not using
  • Leave hoses& clamps attached

Includes

  • Wet Bulb Thermocouple
  • Dry Bulb Thermocouple
  • Vacuum Gauge in Microns
  • Two K-type Thermocouples Pipe Clamps
  • Protective Case
  • Operator's Manual
General Specification
Display 5 inches (diagonal)
Backlight Blue (On for 1 minute unless turned off manually
Battery 6 x AA (Battery life below based on alkaline type)
Battery life (SMAN2) Approx. 500 hours (without backlight)
Battery life (SMAN3) Approx. 135 hours (without backlight)
Low battery indication battery symbol is displayed when the battery voltage drops below the operating level
Auto Shut off 30 minutes of inactivity when APO is activated
Operating environment 32°F to 122°F (0°C to 50°C) at <75% relative humidity
Storage temperature -4°F to 140°F (-20°C to 60°C), 0 to 80% RH (with battery removed)
Temperature coefficient 0.1 x (specified accuracy) per °C (0°C to 18°C, 28°C to 50°C), per 0.6°F (32°F to 64°F, 82°F to 122°F)
Over range "OL" or "-OL" is displayed
Weight 3.05 lbs (1.38 kg)
Pressure
Connector Type Standard 1/4 NPT male flare fitting
Range 29" HgV to 580 Psig (English), 74 cmHgV to 0 to 4000KPa (Metric)
Resolution 0.1 psi/inHg; 1 kPa/cmHg
Accuracy 29" HgV to 0" HgV: ±0.2" HgV
74 cmHgV to 0 cmHgV: ±1 cmHgV
0 to 200 Psig: ±1 Psi; 0 to 1378 KPa: ±7 KPa; 0 to 1.378MPa:
±0.007MPa; 0 to 13.78 bar ±0.07 bar
200 to 580 Psig: ±0.3%+1 Psi; 1378 to 4000KPa: ±0.3%+7 Kpa;
1.378 to 4.000MPa: ±0.3%+0.007MPa; 13.78 to 40.00bar:
±0.3%+0.07bar
Maximum overload pressure 800 psig
Units Psig, kPa, MPa, bar, inHg, and cmHg
Microns for Vacuum (SMAN3 only)
Connector Type Standard 1/4 NPT male flare fitting
Range 50 to 9999 microns of mercury
Resolution 1 micron (50 to 2000 microns), 250 microns (2001 to 5000 microns), 500 microns (5001 to 8000 microns), 1000 microns (8001 to 9999 microns)
Accuracy ±10% or ±10 microns, whichever is greater (50 to 1000 microns)
Maximum Overload pressure 500 psig
Units Microns of mercury
Temperature
Sensor type K-Type thermocouple
Range -95°F to 999.9°F (-70°C to 537.0°C)
Resolution 0.1°F/°C
Accuracy ±(1.0°F) -95°F to 199.9°F; ±(0.5°C) -70°C to 93°C
±(2.0°F) 200°F to 999.9°F; ±(1.0°C) 93°C to 537.0°C

Datasheets & User Manuals