SC77 True RMS Clamp Meter by Fieldpiece

The SC77 is one of our most popular digital multimeters for a reason. It has virtually every parameter for electrical and thermal HVACR testing in one meter. This auto ranger includes a host of safety features including a high-voltage LED and beeper, a continuity warning, push button non-contact voltage (NCV), a lead holder with detachable leads, and alligator probe tips for easy one-handed testing. As far as ranges go, it has temperature, capacitance, microamps DC for flame diode tests, and everyday electrical ranges for HVACR. Not to mention technicians tell us it is one of the most durable meters in the industry.

Designed specifically for HVACR field service, the SC77 is a dedicated DMM and offers specific features and benefits to HVACR field service pros including:

  • Works with Fieldpiece Accessory Heads
  • Non-contact Voltage
  • High Voltage and Continuity Indicators
  • 300AAC
  • Capacitance (MFD)
  • Temperature
  • Microamps DC - Flame Rectification Tests
  • True RMS
  • Silicone Leads with Detachable Probe Tips
  • Bright Blue Backlight
  • Hold
  • Volts AC
  • Volts DC
  • Resistance (Ohms)
  • Diode Test
  • Rugged ABS case
  • Auto power-off
  • Safe one-handed testing

Includes

  • True RMS Clamp Meter with Temperature, Capacitance and Backlight - SC77
  • Wrap Tab K-Type Thermocouple - ATB1
  • Deluxe Silicone Test Leads - ADLS2
  • Alligator Clip Lead Extensions - ASA2
  • Large Single Meter Case - ANC7
  • 9-Volt Battery
  • Operator's Manual
General Specification
Display LCD with a maximum reading of 4000.
Data Hold Operating on all ranges
Range(RNG) Operating on all autoranges
Overrange "OL" mark indication.
Auto power off Approx. 10 minutes
Measurement rate 2 times per second, nominal.
Operating environment 32 to 122°F (0 to 50°C) at <70% R.H.
Storage temperature -4 to 140°F (-20 to 60°C), 0 to 80% R.H. with battery removed.
Accuracy Specifications good in ambient conditions of 73°F ±9°F (23°C ±5°) , <75% relative humidity.
Temperature Coefficient 0.1×(specified accuracy) per °F/°C; 32 to 66°F (0 to 19°C); 82 to 122°F (28 to 50°C).
Altitude 6561.7 Feet (2000m)
Jaw opening capability 38mm conductor
Power Single standard 9-volt battery, NEDA 1604, JIS 006P, IEC 6F22
Battery life 100 hours carbon zinc
200 hours typical with alkaline.
Accessories One pair test leads, one pair of small alligator clips, ktype thermocouple, 9V battery (installed), and operating instructions
Safety Designed to meet IEC/EN61010-1 and IEC/EN61010- 2-032, CATIII 600V, class II and pollution degree 2, indoor use comply with CE. C-Tick.
DC volts
Ranges 400mV, 4000mV, 40V, 400V, 600V
Resolution 0.1mV
Accuracy ±(0.5% rdg + 2 dgt)
Input impedance 3MΩ on V inputs, 10MΩ on mV input
Overload protection 600VDC or AC rms
Transient protection 6kV for 10μ sec
AC volts TrueRMS (50-500Hz)
Ranges 4V, 40V, 400V, 600V
Resolution 1mV
Accuracy ±(2.0% rdg + 8 dgts) 50 ~ 500Hz
Input impedance 3MΩ
Overload protection 600V DC or AC rms
Transient protection 6kV for 10μ sec
AC current TrueRMS (50-60Hz)
Ranges 40A, 300A
Resolution 0.01A
DC Accuracy ±(3.0% rdg + 10 dgts) 0 ~ 300A / 50 ~ 60Hz
Overload protection 300AAC
DC current
Ranges 400μA
Resolution 0.1μA
Accuracy ±(1.0% rdg + 2 dgt)
Voltage burden 1V
Overload protection 500VDC or AC rms
Resistance
Ranges 400Ω, 4kΩ, 40kΩ, 400kΩ, 4MΩ, 40MΩ
Resolution 0.1Ω
Accuracy ±(1.2% rdg + 4 dgts) on 400Ω to 400kΩ ranges
±(1.5% rdg + 4 dgts) on 4MΩ range
±(3.0% rdg + 5 dgts) on 40MΩ range
Open circuit volts -0.45VDC typical, (-1.2VDC on 400Ω range)
Overload protection 500VDC or AC rms
Temperature
Range -30 to 1000°F (-34 to 538°C)
Resolution 0.1°
Accuracy ±1°F, 32 to 120°F (0 to 49°C)
±1%+1.5°F, -4 to 750°F (-20 to 399°C)
±2%+4°F, -30 to -4°F (-34 to -20°C)
±2%+4°F, 750 to 1000°F(399 to 538°C)
Sensor type K-type thermocouple
Overload Protection 60 VDC or 30 VAC rms
Continuity
Range 400Ω
Resolution
Audible indication Less than 25Ω
Response time 500ms
Overload Protection 500VDC or AC rms
Green LED will be on continuously.
Capacitance
Range 4μF, 40μF, 400μF, 4mF 1mF = 1000μF i.e: 1.425mF = 1425μF
Resolution 1nF
Accuracy ±(3% rdg + 10 dgts) on 4μF range
±(3% rdg + 5 dgts) on 40μF to 400μF ranges
±(5% rdg + 20 dgts) on 4mF range
Input protection: 500VDC or AC rms