- All Products
- Shop by Brands
- BW Technologies
- BW Technologies
- BW Technologies Monitors
- Models
- BW Clip
- BW Clip4
- GasAlertClip Extreme
- GasAlert Extreme
- GasAlertMicroClip XT
- GasAlertMicroClip XL
- GasAlertMicroClip X3
- GasAlertQuattro
- GasAlertMax XT II
- GasAlertMicro 5 Series
- SamplerPak
- IntelliDox Docking System
- MicroDock II
- BW Ultra
- BW Solo
- Gas Monitors
- Gas Monitor Manufacturers
- BW Technologies
- Bacharach
- Biosystems
- Crowcon
- Gas Clip Technologies
- GfG Instruments
- GMI/Detcon
- Honeywell Analytics
- Industrial Scientific
- MSA
- RAE Instruments
- RKI Instruments
- Calibration Gas
- Combustion Analyzers
- Water Quality
- Reliability Instruments
- Refractometers
- HVAC
- Weather
- Temperature
- Laboratory
- Sound
- IAQ
- Electrical
- All Categories
Fieldpiece True RMS Clamp Meter - SC77
Item #:
FP-SC77
Brand:
Fieldpiece
Share this product:
SC77 True RMS Clamp Meter by Fieldpiece
The SC77 is one of our most popular digital multimeters for a reason. It has virtually every parameter for electrical and thermal HVACR testing in one meter. This auto ranger includes a host of safety features including a high-voltage LED and beeper, a continuity warning, push button non-contact voltage (NCV), a lead holder with detachable leads, and alligator probe tips for easy one-handed testing. As far as ranges go, it has temperature, capacitance, microamps DC for flame diode tests, and everyday electrical ranges for HVACR. Not to mention technicians tell us it is one of the most durable meters in the industry.
Designed specifically for HVACR field service, the SC77 is a dedicated DMM and offers specific features and benefits to HVACR field service pros including:
- Works with Fieldpiece Accessory Heads
- Non-contact Voltage
- High Voltage and Continuity Indicators
- 300AAC
- Capacitance (MFD)
- Temperature
- Microamps DC - Flame Rectification Tests
- True RMS
- Silicone Leads with Detachable Probe Tips
- Bright Blue Backlight
- Hold
- Volts AC
- Volts DC
- Resistance (Ohms)
- Diode Test
- Rugged ABS case
- Auto power-off
- Safe one-handed testing
Includes
- True RMS Clamp Meter with Temperature, Capacitance and Backlight - SC77
- Wrap Tab K-Type Thermocouple - ATB1
- Deluxe Silicone Test Leads - ADLS2
- Alligator Clip Lead Extensions - ASA2
- Large Single Meter Case - ANC7
- 9-Volt Battery
- Operator's Manual
General Specification | |
Display | LCD with a maximum reading of 4000. |
Data Hold | Operating on all ranges |
Range(RNG) | Operating on all autoranges |
Overrange | "OL" mark indication. |
Auto power off | Approx. 10 minutes |
Measurement rate | 2 times per second, nominal. |
Operating environment | 32 to 122°F (0 to 50°C) at <70% R.H. |
Storage temperature | -4 to 140°F (-20 to 60°C), 0 to 80% R.H. with battery removed. |
Accuracy | Specifications good in ambient conditions of 73°F ±9°F (23°C ±5°) , <75% relative humidity. |
Temperature Coefficient | 0.1×(specified accuracy) per °F/°C; 32 to 66°F (0 to 19°C); 82 to 122°F (28 to 50°C). |
Altitude | 6561.7 Feet (2000m) |
Jaw opening capability | 38mm conductor |
Power | Single standard 9-volt battery, NEDA 1604, JIS 006P, IEC 6F22 |
Battery life | 100 hours carbon zinc 200 hours typical with alkaline. |
Accessories | One pair test leads, one pair of small alligator clips, ktype thermocouple, 9V battery (installed), and operating instructions |
Safety | Designed to meet IEC/EN61010-1 and IEC/EN61010- 2-032, CATIII 600V, class II and pollution degree 2, indoor use comply with CE. C-Tick. |
DC volts | |
Ranges | 400mV, 4000mV, 40V, 400V, 600V |
Resolution | 0.1mV |
Accuracy | ±(0.5% rdg + 2 dgt) |
Input impedance | 3MΩ on V inputs, 10MΩ on mV input |
Overload protection | 600VDC or AC rms |
Transient protection | 6kV for 10μ sec |
AC volts TrueRMS (50-500Hz) | |
Ranges | 4V, 40V, 400V, 600V |
Resolution | 1mV |
Accuracy | ±(2.0% rdg + 8 dgts) 50 ~ 500Hz |
Input impedance | 3MΩ |
Overload protection | 600V DC or AC rms |
Transient protection | 6kV for 10μ sec |
AC current TrueRMS (50-60Hz) | |
Ranges | 40A, 300A |
Resolution | 0.01A |
DC Accuracy | ±(3.0% rdg + 10 dgts) 0 ~ 300A / 50 ~ 60Hz |
Overload protection | 300AAC |
DC current | |
Ranges | 400μA |
Resolution | 0.1μA |
Accuracy | ±(1.0% rdg + 2 dgt) |
Voltage burden | 1V |
Overload protection | 500VDC or AC rms |
Resistance | |
Ranges | 400Ω, 4kΩ, 40kΩ, 400kΩ, 4MΩ, 40MΩ |
Resolution | 0.1Ω |
Accuracy | ±(1.2% rdg + 4 dgts) on 400Ω to
400kΩ ranges ±(1.5% rdg + 4 dgts) on 4MΩ range ±(3.0% rdg + 5 dgts) on 40MΩ range |
Open circuit volts | -0.45VDC typical, (-1.2VDC on 400Ω range) |
Overload protection | 500VDC or AC rms |
Temperature | |
Range | -30 to 1000°F (-34 to 538°C) |
Resolution | 0.1° |
Accuracy | ±1°F, 32 to 120°F (0 to 49°C) ±1%+1.5°F, -4 to 750°F (-20 to 399°C) ±2%+4°F, -30 to -4°F (-34 to -20°C) ±2%+4°F, 750 to 1000°F(399 to 538°C) |
Sensor type | K-type thermocouple |
Overload Protection | 60 VDC or 30 VAC rms |
Continuity | |
Range | 400Ω |
Resolution | 1Ω |
Audible indication | Less than 25Ω |
Response time | 500ms |
Overload Protection | 500VDC or AC
rms Green LED will be on continuously. |
Capacitance | |
Range | 4μF, 40μF, 400μF, 4mF 1mF = 1000μF i.e: 1.425mF = 1425μF |
Resolution | 1nF |
Accuracy | ±(3% rdg + 10 dgts) on
4μF range ±(3% rdg + 5 dgts) on 40μF to 400μF ranges ±(5% rdg + 20 dgts) on 4mF range |
Input protection: | 500VDC or AC rms |