- All Products
- Shop by Brands
- BW Technologies
- BW Technologies
- BW Technologies Monitors
- Models
- BW Clip
- BW Clip4
- GasAlertClip Extreme
- GasAlert Extreme
- GasAlertMicroClip XT
- GasAlertMicroClip XL
- GasAlertMicroClip X3
- GasAlertQuattro
- GasAlertMax XT II
- GasAlertMicro 5 Series
- SamplerPak
- IntelliDox Docking System
- MicroDock II
- BW Ultra
- BW Solo
- Gas Monitors
- Gas Monitor Manufacturers
- BW Technologies
- Bacharach
- Biosystems
- Crowcon
- Gas Clip Technologies
- GfG Instruments
- GMI/Detcon
- Honeywell Analytics
- Industrial Scientific
- MSA
- RAE Instruments
- RKI Instruments
- Calibration Gas
- Combustion Analyzers
- Water Quality
- Reliability Instruments
- Refractometers
- HVAC
- Weather
- Temperature
- Laboratory
- Sound
- IAQ
- Electrical
- All Categories
Fieldpiece Wireless Swivel-head Clamp Meter - SC57
Item #:
FP-SC57
Brand:
Fieldpiece
Share this product:
SC57 Wireless Swivel-head Clamp Meter by Fieldpiece
The SC57 is the top-of-the-line clamp meter from Fieldpiece Instruments. Packed with measurements HVACR pros need, the SC57 receives wireless HVACR measurements up to 75' away from the testing point.So, you can get HVACR readings, from anywhere on the jobsite, sent directly to the SC57 meter in your hand!
- Live temperature split readings while working on the condenser
- Accurate amps with the blower door firmly closed
- Real-time vacuum readings from anywhere on the job site
- Wireless Measurements for faster, more accurate readings
- 180° Swivel Head Clamp to easily view your results at any angle
- Clamp Flashlight to illuminate wires in dark spaces
- Bright Blue Backlight stays on for 3 minutes for easy readings
- Rugged Construction to withstand harsh conditions
- Automatic Power Off (APO) to preserve your battery life when clamp isn't in use
- Non-Contact Voltage warning via audio and visual alarms
- Easy Field Calibration with convenient pot location to quickly calibrate K-type thermocouples
- True RMS to accurately measure non-sinusoidal wave forms
- Auto Ranging for quick, accurate readings
- Constant Battery Status so you don't run out of batteries in the middle of a job
The SC57 is simply the best HVACR clamp meter on the market. It provides fast and accurate readings for all the measurements HVACR techs take everyday, plus it's wireless. It's the only clamp meter on the market that can take true wireless readings. And with that, techs can do a faster, more accurate job. There are countless ways wireless measurements can help HVACR techs do a better job, but there are two main issues solved by taking measurements wirelessly.
Less time & hassle -- A large part of a techs day is spent walking back and forth between measurement points, and adjustment points. With the SC57 wireless clamp meter, techs can wirelessly send measurement readings directly to the meter at the adjustment point. So things like indoor wet bulb can be read while techs are at the condenser making adjustments.
Better accuracy -- Wireless measurements give HVACR pros a real-time snapshot of the system, so measurements are taken under the exact same conditions. So temperatures and pressures don't have time to change between different readings. The real-time measurements allow techs to accurately install, service, and charge systems.
In addition to being able to expand testing capabilities wirelessly with any Fieldpiece accessory head, the SC57 has these measurements built right in:
Includes
- SC57 - Wireless Swivel Head Clamp Meter
- ET2W - Wireless Transmitter
- ADLS2 - Deluxe Silicone Test Leads
- ASA2 - Alligator Clip Lead Extensions
- ATB1 - K-type Thermocouple
- ANC7 - Large Single Meter Case
- Velcro Strap
General Specification | |
Wireless range | Up to 75 feet (23m) line of sight |
Minimum wireless distance | 1 foot (30cm) |
Wireless frequency | 910MHz to 920MHz (US), 868.1MHz to 868.5MHz (European) |
Display | 10000 count display with backlight |
Overrange | (OL) or (-OL) is displayed |
Measurement rate | 2 times per second, nominal |
Zero | Automatic |
Operating environment | 32°F to 122°F (0°C to 50°C) at <70% relative humidity |
Storage temperature | -4°F to 140°F (-20°C to 60°C), 0 to 80% RH (with battery removed) |
Accuracy | Stated accuracy @ 73°F±9°F (23°C±5°C), <75%RH |
Temperature coefficient | 0.1 x (specified accuracy) per °C [0°C to 18°C (32°F to 64°F), 28°C to 50° C(82°F to 122°F)] |
Accuracy Specification | Calculate against a known value |
APO (Auto Power Off) | Approx. 30 minutes |
Power | Single standard 9-volt battery, NEDA 1604, JIS 006P, IEC 6F22 |
Battery life | 100 hours typical alkaline |
Low battery indication | Battery icon will be empty. "batt" displays along with a continuous beep when the battery voltage drops below the operating level. Meter shuts off in 5 seconds. |
Dimensions | 258.3mm(H) x 71.2mm(W) x 42.7mm(D) |
Weight | Approx. 278g including battery |
Altitude | 6562 feet (2000m) |
Overload protection | 600VDC or 600VAC rms unless otherwise stated in the individual test sections. |
Test leads | Use UL listed test leads that comply to UL61010-031 rated CATIII 600V or above. Included test leads are gold-plated and have removeable safety caps |
Temperature (°F/°C) | |
Range | -40°F to 2200°F, (-40°C to 1200°C) |
Resolution | 0.1° |
Accuracy | ±(1°F) 32°F to 120°F, ±(1°C) 0°C to 49°C ±(1%+2°F) 120°F to 750°F, ±(1%+1°C) 49°C to 400°C ±(2%+6°F) -40°F to 32°F, ±(2%+3°C) -40°C to 0°C ±(2%+6°F) 750°F to 2200°F, ±(2%+3°C) 400°C to 1200°C |
Sensor type | K-type thermocouple |
Overload protection | 30 VDC or 30VAC rms |
Voltage AC (VAC) (50Hz-400Hz) | |
Ranges | 0 to 600V |
Resolution | 0.1V |
Accuracy | ±(1.0% + 5 dgts) 50-100Hz ±(6%+5 dgts) 100-400Hz |
True RMS | Yes |
Crest factor | ≤ 3 |
Input impedance | 1MΩ |
MicroAmps DC (µADC) | |
Ranges | 1000µA |
Resolution | 0.1µA |
Accuracy | ±(1.0% + 5 dgts) |
Voltage burden | 1V |
Overload Protection | 600VDC or 600VAC rms |
Frequency (Hz) Through Leads | |
Ranges | 20 to 400Hz |
Resolution | 0.1Hz |
Accuracy | ±(0.5% + 5 dgts) |
Sensitivity | 5V rms on VAC range. |
Capacitance (MFD) | |
Ranges | 0 to 1000µF |
Resolution | 0.1µF |
Accuracy | ± (5% + 15 dgts) |
Overload Protection | 600VDC or 600VAC rms |
Voltage DC (VDC) | |
Ranges | 0 to 600V |
Accuracy | ±(1.0% + 5 dgts) on 600V range |
Resolution | 0.1V |
Input impedance | 1MΩ |
Resistance (Ω) | |
Ranges | 0 to 1000Ω, 1000Ω to 9999Ω |
Resolution | 0.1Ω |
Accuracy | ±(1.5% + 5 dgts) |
Overload Protection | 600VDC/VAC rms |
Continuity | |
Range | 1000Ω |
Resolution | 0.1Ω |
Response time | 100ms |
Audible beep | <30Ω |
Overload Protection | 600VDC/VACrms |
Non Contact Voltage (NCV) | |
AC Voltage Detection Range | 24VAC to 600VAC (50-60Hz) |
Amps AC (AAC) TrueRMS (50-60Hz) | |
Ranges | 0 to 400AAC |
Resolution | 0.1A |
Crest factor | ≤ 3 |
Accuracy | ±(2.0% + 5 dgts) 50-60Hz |
Jaw Opening | 1.2in (30 mm |
Overload Protection | 400AAC |
Frequency (Hz) Through Clamp | |
Range | 20Hz to 400H |
Accuracy | ±(0.5% + 5) |
Minimum current range | > 5AAC at 20 to 100Hz, >10AAC at 100 to 400Hz |
Resolution | 0.1Hz |
Overload Protection | 400AAC |