- All Products
- Shop by Brands
- BW Technologies
- BW Technologies
- BW Technologies Monitors
- Models
- BW Clip
- BW Clip4
- GasAlertClip Extreme
- GasAlert Extreme
- GasAlertMicroClip XT
- GasAlertMicroClip XL
- GasAlertMicroClip X3
- GasAlertQuattro
- GasAlertMax XT II
- GasAlertMicro 5 Series
- SamplerPak
- IntelliDox Docking System
- MicroDock II
- BW Ultra
- BW Solo
- Gas Monitors
- Gas Monitor Manufacturers
- BW Technologies
- Bacharach
- Biosystems
- Crowcon
- Gas Clip Technologies
- GfG Instruments
- GMI/Detcon
- Honeywell Analytics
- Industrial Scientific
- MSA
- RAE Instruments
- RKI Instruments
- Calibration Gas
- Combustion Analyzers
- Water Quality
- Reliability Instruments
- Refractometers
- HVAC
- Weather
- Temperature
- Laboratory
- Sound
- IAQ
- Electrical
- All Categories
Fieldpiece Superheat & Subcooling Accessory Head - ASX14
Item #:
FP-ASX14
Brand:
Fieldpiece
Share this product:
ASX14 Superheat & Subcooling Accessory Head by Fieldpiece
Recent studies suggest that the majority of A/C systems in operation in the U.S. are under or overcharged. This causes decreased efficiency, and sometimes, premature compressor failure. The Fieldpiece Superheat and Subcooling Accessory for Air Conditioning, model ASX14, measures suction line, or low side, line temperature and pressure.
It then calculates actual superheat in real time using built in P/T charts. It also measures liquid line, or high side, line temperature and pressure, and calculates actual subcooling. Use it to get actual superheat on R-22 and R-410A fixed orifice systems and actual subcooling on TXV / TEV regulated systems. Use the "T" fitting to charge to actual superheat or subcooling by putting the ASX14 in-line between your refrigerant bottle and the system.
Designed for HVACR professionals, the ASX14, measures refrigerant pressure and temperature, and calculates superheat for two refrigerants in English or metric units.
- Display pressure in PSI or kPa
- Display temperature in °F or °C
- Display superheat in °F or °C
- Select R22 or R410A
- Auto-off can be disabled for data logging
- Includes "T"
- Accepts K-type thermocouples
- ATC1 pipe clamp T/C included
- LED indicates when readings are stable
- Thermocouple calibration pot
- Push-button atmosphere pressure calibration
Includes
- Superheat and Subcooling Accessory for Air Conditioning - ASX14
- Pipe-Clamp Thermocouple 3/8" to 1 3/8" for Air Conditioning - ATC1
- Mini-calibration Screwdriver
- 9V Battery (installed)
- Operator's Manual
General Specification | |
Operating environment | 32ºF to 122ºF; 0ºC to 50ºC at <75%RH |
Storage environment | -4ºF to 140ºF; -20ºC to 60ºC at <80%RH with battery removed. |
Battery life | 25 hours typical. No measurable current draw when in "off" position. |
Low battery indication | Red LED lights |
Battery | 9V |
Auto off | Approx. 15 minutes |
Overloads | The ASX14 outputs 3.4V when temperature or pressure is outside of their working range (overloaded). For ranges below 3400mVDC, the normal overload symbol will be displayed on the meter (“OL”). For ranges above 3400mVDC, reading displayed will be approximately 3.4VDC. |
Stated Accuracy | at 73°F ± 9°F (23°C ±5°C), <90% R.H. |
Temperature | |
Range (temperature) | -40ºF to 400ºF; -40ºC to 204ºC |
Resolutions | 0.1º |
Sensor type | k-type thermocouple |
Pipe clamp thermocouple accuracy | ±4ºF (±2°C) or ±0.75%, whichever is greater, -30ºF to 200ºF (-34°C to 93°C) |
System accuracy | ±1ºF;±0.06ºC @ 73ºF ± 5ºF |
Pressure and vacuum | |
Working range (pressure) | 0 to 500 psi; 0 to 4000 kPa |
Max displayed pressure | 800psi (5500 kPa) |
Working range (vacuum) | 29”Hg vac. to 0; 74cmHg vac. to 0 Vacuum will show up as negative value on meter |
Resolutions | 0.1psi or kPa, 0.1”Hg or cmHg vac. |
Accuracy | 0 to 200 psig, ±1 psi, 0 to 1378 kPa ±6.9 kPa; 200 to 500 psig, 0.3% ±1 psi, 1378 to 3447 kPa 0.3% ±6.9kPa |
Sensor breakdown pressure | 800psi (5500 kPa) |
Superheat | |
Range (temperature) | 0ºF to 80ºF; 0ºC to 27ºC |
Resolutions | 0.1º |
System Accuracy | ±1ºF @ 73ºF ± 5ºF (±0.06ºC @ 23ºC ± 3ºC after calibration |
Subcooling | |
Range (temperature) | 0ºF to 80ºF; 0ºC to 27ºC |
Resolutions | 0.1º |
System Accuracy | ±1ºF @ 73ºF ± 5ºF (±0.06ºC @ 23ºC ± 3ºC after calibration |