RAE Systems Humidity Filtering II Tube (10 Tubes / Box) - 025-2002-010

Item #:
RAE-025-2002-010
Brand:
RAE Systems
RAE Systems Humidity Filtering II Tube (10 Tubes / Box) - 025-2002-010
$85.00
Qty
Send This Page to a Friend

Ask an Expert

Our tech experts are ready to help!

1-866-4 JJSTECH (1-866-455-7832)

Email Us
Share this product:
RAE Systems Humidity Filtering II Tube (10 Tubes / Box) - 025-2002-010

RAE Systems Humidity Filtering II Tube (10 Tubes / Box) - 025-2002-010

$85.00

025-2002-010 Humidity Filtering II Tube (10 Tubes / Box) by RAE Systems

The Humidity Filtering II Tube dries the sample gas entering pumped instruments. It is particularly suited for removing humidity effects on photoionization detectors (PIDs) while making VOC measurements, and typically lasts for about a half hour of continuous readings. The Humidity Filtering II Tube utilizes a solid adsorbent to remove moisture without impacting the detection and measurement of most VOCs.

Key Features

  • Enables continuous reading of VOCs under extremely humid conditions for about one half hour (per tube) at room temperature
  • Prevents drifting readings at high humidity when the sensor is dirty.
  • Attaches to the Flex-I-Probe™ inlet with the same adapter used for ppbRAE 3000 VOC zeroing tubes.
  • Especially useful for measuring chlorinated solvents and fuels under high humidity conditions as are often encountered during soil and water remediation.
  • Can be used with other instruments having a built-in pump such as MiniRAE Lite, ppbRAE 3000, UltraRAE 3000, MultiRAE Lite, MultiRAE and MultiRAE Pro when humidity is an issue, when using a PID or making low-level LEL sensor measurements.
  • Caution: Absorbs some compounds such as ammonia and slows the response of heavy compounds, especially at low concentrations or low temperatures.

Applications

  • Soil and water remediation
  • VOCs in landfill sites
Humidity Filtering Capacity
Temp °C Temp °F Relative Humidity (%) Run time to t10 (min @ 500 cc/min) Run time to t20 (min @ 500 cc/min)
45 113 99 12 14
75 17 18
50 35 >40
25 >40 >40
40 104 100 18 20
75 25 30
50 40 >40
30 86 100 22 26
75 28 32
50 40 >40
20 68 100 23  
75 34 >40
50 40    

Effect on VOC Response
Compound Conc. (ppm) Temp (°C) t90 (sec) CF*
Isobutylene 100 22 3 1.0
Isobutylene 10 0 5 1.17
Cyclohexane 10 22 3 1.0
Octane 100 22 3 1.0
Undecane 100 22 60 1.1
Benzene 5 22 3 1.0
Toluene 10 22 3 1.0
Xylene 100 22 10 1.05
Styrene 50 22 10 1.0
Gasoline 100 22 15 1.05
Gasoline 10 22 10 1.0
Gasoline 10 0 28 1.6
Jet Fuel JP-5 10 22 65 1.0
Diesel Fuel 100 22 3 1.0
Vinyl Chloride 10 22 3 1.0
Trichloroethylene 10 22 3 1.0
Trichloroethylene 10 0 5 1.2
Perchloroethylene 10 22 4 1.0
Glutaraldehyde 10 22 NR** (480) NR** (1.05)
Ethanol 1000 22 3 1.0
Ethanol 100 22 40 1.0
Isopropanol 10 22 90 1.15
Acetone 1000 22 3 1.0
Acetone 100 22 20 1.0
Acetone 10 22 80 1.0
Acetone 10 0 115 1.17
Phenol 20 22 150 1.0
Methyl methacrylate 10 22 150 1.05
Dimethyl sulfide 10 22 3 1.0
Ethyl mercaptan 10 22 4 1.05
Butyl mercaptan 10 22 5 1.05
Hydrogen sulfide 7 22 3 1.0
Ethylamine high 22 NR** NR**
Ammonia 50 22 NR** NR**
* CF = Correction Factor. Multiply by reading to get true concentration to correct from some loss.
** Not recommended because of severe losses.