- All Products
- Shop by Brands
- BW Technologies
- BW Technologies
- BW Technologies Monitors
- Models
- BW Clip
- BW Clip4
- GasAlertClip Extreme
- GasAlert Extreme
- GasAlertMicroClip XT
- GasAlertMicroClip XL
- GasAlertMicroClip X3
- GasAlertQuattro
- GasAlertMax XT II
- GasAlertMicro 5 Series
- SamplerPak
- IntelliDox Docking System
- MicroDock II
- BW Ultra
- BW Solo
- Gas Monitors
- Gas Monitor Manufacturers
- BW Technologies
- Bacharach
- Biosystems
- Crowcon
- Gas Clip Technologies
- GfG Instruments
- GMI/Detcon
- Honeywell Analytics
- Industrial Scientific
- MSA
- RAE Instruments
- RKI Instruments
- Calibration Gas
- Combustion Analyzers
- Water Quality
- Reliability Instruments
- Refractometers
- HVAC
- Weather
- Temperature
- Laboratory
- Sound
- IAQ
- Electrical
- All Categories
Milwaukee Mi180 pH / ORP / Conductivity / TDS / NaCl / Temperature Laboratory Bench Meter
Item #:
MW-Mi180-US
Brand:
Milwaukee
Share this product:
Mi180 pH / ORP / Conductivity / TDS / NaCl / Temperature Laboratory Bench Meter by Milwaukee
Mi180 measures 6 different parameters: pH, ORP, EC, TDS (Total Dissolved Solids), percentage of NaCl and temperature in a variety of ranges.
pH calibration can be performed in 3 points selectable between 7 memorized buffers, to provide a very accurate calibration curve even when testing different samples, where very wide differences in pH can be found.
The auto-ranging feature for EC and TDS measurements automatically sets the resolution suitable to the tested sample. All measurements can be temperature compensated at 20 or 25°C and the compensation coefficient is selectable by the user.
The automatic temperature compensation can also be disabled for measuring the actual conductivity value. The stability indicator on the LCD ensures accuracy. Conductivity readings are performed with the 4-ring probe supplied with the meter.
The GLP feature allows users to store and recall data on system status.
Range | pH: -2.00 to 16.00 pH; -2.000 to 16.000 pH mV: ±699.9 mV; ±2000 mV EC: 0.00 to 29.99 µS/cm; 30.0 to 299.9 µS/cm; 300 to 2999 µS/cm; 3.00 to 29.99 mS/cm; 30.0 to 200.0 mS/cm; up to 500.0 mS/cm (uncompensed EC*) TDS: 0.0 to 14.99 mg/L (ppm); 15.0 to 149.9 mg/L (ppm); 150 to 1499 mg/L (ppm); 1.50 to 14.99 g/L (ppt); 15.0 to 100.0 g/L (ppt); up to 400.0 g/L actual TDS (with 0.80 factor) NaCl: 0.0 to 400.0% Temp: -20.0 to 120.0°C / -4.0 to 248.0°F |
Resolution | pH: 0.01 pH; 0.001 pH mV: 0.1 mV; 1 mV EC: 0.01 µS/cm; 0.1 µS/cm; 1 µS/cm; 0.01 mS/cm; 0.1 mS/cm TDS: 0.01 mg/L; 0.1 mg/L; 1.0 mg/L; 0.01 g/L; 0.1 g/L NaCl: 0.1% Temp: 0.1°C / 0.1°F |
Accuracy | pH: ±0.01 pH; ±0.002 pH mV: ±0.2 mV; ±1 mV EC: ±1% of reading ±(0.05 µS/cm or 1 digit) TDS: ±1% of reading ±(0.03 ppm or 1 digit) NaCl: ±1% reading Temp: ±0.4°C / ±0.8°F |
Rel mV offset | ±2000 mV |
Calibration | pH: 1, 2 or 3 points calibration, with 7 memorized buffers (pH 1.68, 4.01, 6.86, 7.01, 9.18, 10.01 and 12.45) EC: 1 point slope calibration with 6 memorized solutions: (84 µS/cm, 1413 µS/cm, 5.00 mS/cm, 12.88 µS/cm, 80.0 µS/cm, 111.8 mS/cm) NaCl: 1 point, with MA9066 solution Temp: 2 point, at 0 and 50°C / 32 and 122°F |
Temperature Compensation | automatic or manual, from -20.0 to 120.0°C / -4.0 to 248.0°F |
Temperature Coefficient | selectable from 0.00 to 6.00%/°C (EC and TDS only) |
pH Electrodes & Temp Probe | MA917B/1 & MA831R (included) |
EC/TDS/NaCl/Temp Probe | MA814DB/1 (included) |
TDS Factor | 0.40 to 0.80 (default value is 0.50) |
Logging | up to 50 records, LOG on demand or auto-logging |
GLP | last pH, EC, NaCl calibration data |
PC Interface | RS232 / USB Opto-isolated |
Environment | 0 to 50°C / 32 and 122°F; max RH 95% |
Input Impedance | 1012 Ohm |
Power supply | 12 VDC power adapter (included) |
Dimensions | 230 x 160 x 95 mm |
Weight | 0.9 kg |