Mi170 Autoranging Conductivity / TDS / NaCl / Temperature Laboratory Bench Meter by Milwaukee

Mi170 measures 4 different parameters - EC, TDS (Total Dissolved Solids), percentage of NaCl and temperature in a variety of ranges.

The auto-ranging feature for EC and TDS measurements automatically sets the resolution suitable to the tested sample. All measurements can be temperature compensated at 20 or 25°C and the compensation coefficient is selectable by the user.

The automatic temperature compensation can also be disabled for measuring the actual conductivity value. The stability indicator on the LCD ensures accuracy.

Conductivity readings are performed with the 4-ring probe supplied with the meter. The GLP feature allows users to store and recall data on system status.

PC compatible through an RS232 or USB port.

Range EC: 0.00 to 29.99 µS/cm; 30.0 to 299.9 µS/cm; 300 to 2999 µS/cm; 3.00 to 29.99 mS/cm; 30.0 to 200.0 mS/cm; up to 500.0 mS/cm actual conductivity (uncompensated EC
TDS: 0.00 to 14.99 mg/L (ppm); 15.0 to 149.9 mg/L (ppm); 150 to 1499 mg/L (ppm); 1.5 to 14.99 g/L (ppt); 15.0 to 100.0 g/L (ppt); up to 400.0 g/L actual TDS* (with 0.80 factor)
NaCl: 0.0 to 400.0%
Temp: -20.0 to 120.0°C / -4.0 to 248.0°F
Resolution EC: 0.01 µS/cm; 0.1 µS/cm; 1.0 µS/cm; 0.01 mS/cm; 0.1 mS/cm
TDS: 0.01 mg/L; 0.1 mg/L; 1.0 mg/L; 0.01 g/L; 0.1 g/L
NaCl: 0.1%
Temp: 0.1°C / 0.1°F
Accuracy EC: ±1% of reading ±(0.05 µS/cm or 1 digit)
TDS: ±1% of reading ±(0.03 mg/L or 1 digit)
NaCl: ±1% of reading
Temp: ±0.4°C / ±0.8°F
Calibration EC: 1 point slope calibration with 6 memorized solutions (84.0 µS/cm, 1413 µS/cm, 5.00 mS/cm, 12.88 mS/cm, 80.0 mS/cm, 111.8 mS/cm)
NaCl: 1 point, with MA9066 calibration solution
Temp: 2 points, 0 to 50°C / 32 to 12 °F
Temp. Compensation automatic or manual, from -20.0 to 120.0°C / -4.0 to 248.0°F
Temp. Coefficient selectable from 0.00 to 6.00%/°C (EC and TDS only)
Probe MA814DB/1 4-ring probe with built-in temperature sensor (included)
TDS Factor 0.40 to 0.80 (default value is 0.50)
Logging up to 50 records, LOG on demand or auto-logging
GLP last EC, NaCl calibration data
PC Interface RS232 / USB Opto-isolated
Environment 0 to 50°C / 32 to 122°F; max RH 95%
Power supply 12 VDC power adapter (included)
Dimensions 230 x 160 x 95 mm
Weight 0.9 kg