mPower Electronics POLI Pump usCSAc NDIR CO2/LEL/O2-LF/H2S + CO - MPA1-81A3A6-0T0L0

Item #:
MPA1-81A3A6-0T0L0
Brand:
mPower Electronics
mPower Electronics POLI Pump usCSAc NDIR CO2/LEL/O2-LF/H2S + CO - MPA1-81A3A6-0T0L0
$1,904.00
Qty
Send This Page to a Friend

Ask an Expert

Our tech experts are ready to help!

1-866-4 JJSTECH (1-866-455-7832)

Email Us
Share this product:
mPower Electronics POLI Pump usCSAc NDIR CO2/LEL/O2-LF/H2S + CO - MPA1-81A3A6-0T0L0

mPower Electronics POLI Pump usCSAc NDIR CO2/LEL/O2-LF/H2S + CO - MPA1-81A3A6-0T0L0

$1,904.00

MPA1-81A3A6-0T0L0 POLI Pump usCSAc NDIR CO2/LEL/O2-LF/H2S + CO by mPower Electronics

The POLI multi-gas meters offer 4-gas monitoring of toxic gases, oxygen (O2), combustibles (LEL), carbon dioxide (CO2) and volatile organic compounds (VOCs). The POLI MP400P is an advanced model with built-in pump that allows a full selection of sensors for a wide range of applications, including Confined Space Entry, while the POLI MP400 is a basic, 4-gas diffusion detector for worker safety at hazardous locations. Smart sensors carry calibration and ID information with them for quick exchange in the field during Hazmat response. Specific sensors include electrochemical (EC) for carbon monoxide (CO), hydrogen sulfide (H2S), ammonia (NH3), hydrogen cyanide (HCN), hydrogen chloride (HCl), chlorine (Cl2), chlorine dioxide (ClO2), nitric oxide (NO), nitrogen dioxide (NO2), sulfur dioxide (SO2), ethylene oxide, methyl mercaptan, and others. Also available are pellistor for LEL level combustibles, non-dispersive infrared (NDIR) for Vol% level CO2 or methane, and photo-ionization detector (PID) for ppm level VOCs. Use of combination CO/H2S or SO2/H2S and CH4/CO2 sensors allows up to 6 gas measurements in a single instrument. The MP400/400P has rugged construction and easy-to-learn 2-button operation. The unique Man-Down alarm feature notifies team workers wirelessly if a user becomes incapacitated.

Features, Functions and Benefits

  • Wide selection of "plug-and-play" Smart Sensors (carry calibration data)
  • 4 Sensor slots for up to 6 gas measurements using combination sensor
  • 16-Hour rechargeable Li-ion battery
  • Pump-off switch and low-power sensor options save battery for longer operation
  • 360-Degree LED alarm bar and Man-Down alarm; Flip screen
  • USB Micro charger & communications cable
  • Optional POLI MonoDock station for automated bump test and calibration
  • 6 Months continuous datalogging
  • Durable double shot outer case
  • Wireless remote team communication available (see mSquad & mPlatoon datasheets)
  • Mobile App for POLI simulation and training in smartphone or tablet
Detector Specifications
Size 5.74 x 3.31 x 1.65 in (140 x 84 x 42 mm)
Weight 15.5 oz (435 g)
Sensors Over 30 interchangeable and field-replaceable sensors including PID for VOCs, EC for Toxic and O2, Pellistor for LEL, and NDIR for LEL, Vol% & CO2
Response Time (t90) • 15 seconds (LEL/CO/H2S/O2)
• Others vary – see TA Note 4 at www.mpowerinc.com
Battery Rechargeable Li-ion pack: 16 hours in diffusion mode, 12 hours with pump
Direct Readout • Real-time reading of gas concentration
• PID measurement gas and correction factor
• Visual compliance indicator
• Battery status
• Datalogging on/off
• STEL, TWA, peak and minimum values
• Man-Down alarm on/off
Display 128 x 128 graphical LCD, 1.77 x 1.73 in (45 x 44 mm), with LED backlight for enhanced readability. Automatic screen "flip" feature
Keypad 2 Operation keys
Sampling Bulit-in pump (MP400P) or diffusion (MP400)
Calibration Manual calibration or automated using POLI Docking Box. CaliCase option allows automatic bump test and calibration on up to 4 units simultaneously
Alarms • Audible (95 dB @ 30 cm)
• Visual (flashing bright red LEDs)
• Vibration
• On-screen indication of alarm conditions
• Man-Down alarm with pre-alarm
• Panic Alarm (manual)
Datalogging Continuous datalogging (6 months for 4 sensors at 1-minute intervals, 24 hours/day and 7 days/week)
Charging and Communication Charging, data download, instrument setup and firmware upgrades on PC or laptop via PC comm, cradle, travel charger, or CaliCase.
Temperature -4° to 122°F (-20° to 50°C)
Humidity 0% to 95% Relative humidity (non-condensing)
Warranty • 2 Years on instruments
• 2 Years on sensors for LEL, LEL/Vol, O2, CO, CO2, H2S, SO2, HCN, NO, NO2, and PH3
• 1 Year on other sensors

Sensor Options‡
Sensor
Range
Resolution
PIDP
0-200 ppm
0-2000 ppm
0-10000 ppm
0.01 ppm
0.1 ppm
1 ppm
Oxygen (O2)
Lead Wool: 0-30%Vol
Lead Wool: 0.1%Vol
Lead-Free: 0-30%Vol
Lead-Free: 0.1%Vol
Combustibles (LEL%)
0-100%LEL
0.1%/1%LEL
NDIR Methane (LEL%)
0-100%LEL
1%LEL
NDIR Methane (Vol%)
0-100%Vol
0.1%Vol
Dual-Range LEL%/Vol%
0-100%Vol
1%LEL
NDIR Dual-gas CH4
0-100%LEL
1%LEL
Methane + CO2
0-50000 ppm
100 ppm
CO2 (Carbon Dioxide)
0-50000 ppm
100 ppm
CO (Carbon Monoxide)
0-1000 ppm
1 ppm
H2S (Hydrogen Sulfide)
0-1000 ppm
1 ppm
CO + H2S
CO: 0-500 ppm
H2S: 0-200 ppm
CO: 1 ppm
H2S: 0.1 ppm
SO2 + H2S
SO2: 0-20 ppm
H2S: 0-100 ppm
SO2: 0.1 ppm
H2S: 0.1 ppm
NH3 (Ammonia)P
0-100 ppm
0-500 ppm
1 ppm
1 ppm
Cl2 (Chlorine)P
0-50 ppm
0.1 ppm
ClO2 (Chlorine Dioxide)P
0-1 ppm
0.01 ppm
COCl2 (Phosgene)P
0-1 ppm
0.01 ppm
H2 (Hydrogen)
0-1000 ppm
1 ppm
HCl (Hydrogen Chloride)P
0-15 ppm
0.1 ppm
HF* (Hydrogen Fluoride)P
0-20 ppm
0.1 ppm
HCN (Hydrogen Cyanide)P
0-100 ppm
0.1 ppm
NO (Nitric Oxide)
0-250 ppm
1 ppm
NO2 (Nitrogen Dioxide)P
0-20 ppm
0.1 ppm
N2O (Nitrous Oxide)
0-1000 ppm
10 ppm†
PH3 (Phosphine)
0-20 ppm
0-1000 ppm
0.01 ppm
1 ppm
SO2 (Sulfur Dioxide)
0-20 ppm
0-100 ppm
0.1 ppm
0.1 ppm
C2H4O (Acetaldehyde)P
0-20 ppm
0.1 ppm
ETO (Ethylene Oxide)P
0-100 ppm
0.1 ppm
CH3SH (Methyl Mercaptan)
0-10 ppm
0.1 ppm
THT (Tetrahydrothiophene)P
0-40 ppm
0.1 ppm
P Use in pumped models is strongly preferred * Check availability
† 100 ppm deadband ‡See TA Note 4 for all sensor specifications