- All Products
- Shop by Brands
- BW Technologies
- BW Technologies
- BW Technologies Monitors
- Models
- BW Clip
- BW Clip4
- GasAlertClip Extreme
- GasAlert Extreme
- GasAlertMicroClip XT
- GasAlertMicroClip XL
- GasAlertMicroClip X3
- GasAlertQuattro
- GasAlertMax XT II
- GasAlertMicro 5 Series
- SamplerPak
- IntelliDox Docking System
- MicroDock II
- BW Ultra
- BW Solo
- Gas Monitors
- Gas Monitor Manufacturers
- BW Technologies
- Bacharach
- Biosystems
- Crowcon
- Gas Clip Technologies
- GfG Instruments
- GMI/Detcon
- Honeywell Analytics
- Industrial Scientific
- MSA
- RAE Instruments
- RKI Instruments
- Calibration Gas
- Combustion Analyzers
- Water Quality
- Reliability Instruments
- Refractometers
- HVAC
- Weather
- Temperature
- Laboratory
- Sound
- IAQ
- Electrical
- All Categories
SMC ISE40A High Precision 2-Color Display Digital Pressure Switch - ISE40A-N01-Y-PA
Item #:
ISE40A-N01-Y-PA
Brand:
SMC
Share this product:
ISE40A High Precision 2-Color Display Digital Pressure Switch by SMC
Pressure Switch ISE40A series is a high precision digital switch, providing improved functions, performance and variations over the previous ISE40 series. Abnormal values can be seen at a glance on the 2-color display. The settings of the master pressure switch can be copied to up to 10 slave pressure switches, reducing the setting work, and preventing mistakes in setting. Other features include: simple 3-step setting, analog output, wide variety of piping variations, and a power-saving function for MPa-kPa. The ISE40A is also CE, UL/CSA and RoHS compliant.
- High precision digital pressure switch w/2-color display
- IP65 and RoHS compliant
- Capable of copying up to 10 switches simultaneously
- 3-step setting
- Space saving design w/several piping and mounting variations
Product contains:
- SMC 2-COLOR HI PRECISIONDIG PRES SWITCH
- N01 (NPT 1/8, M5 Female Thread)
- Y (PNP Open Collector 2 Outputs+Copy Function)
- P (Unit Switching Function, Initial Value psi, Not Allowed for Use in Japan)
- Lead Wire 2m
Model No. | ZSE40A (For vacuum) |
ZSE40AF (For compound) |
ISE40A (For positive pressure) |
||
Rated pressure range | 0 to -101.3 kPa |
-100.0 to 100.0 kPa |
-0.100 to 1.000 MPa |
||
Set pressure range | 10.0 to -105.0 kPa |
-105.0 to 105.0 kPa |
-0.105 to 1.050 MPa |
||
Withstand pressure | 500 kPa |
500 kPa |
1.5 MPa |
||
Minimum display unit | 0.1 kPa |
0.1 kPa |
0.001 MPa |
||
Applicable fluid | Air, inert gases and incombustible gases |
||||
Power supply voltage | 12 to 24 VDC ±10%, ripple (p-p) 10% or less (protected against reverse connection) |
||||
Current consumption | 45 mA or less |
||||
Switch output | NPN or PNP open collector output 2 outputs
|
||||
Max. load current | 80 mA |
||||
Max. applied voltage | 28 V (NPN output) |
||||
Residual voltage | 1 V or less (at 80 mA load current) |
||||
Response time | 2.5 ms or less (Chattering-proof function working: 20, 100, 500, 1000 or 2000 ms selected)
|
||||
Short circuit protection | Provided |
||||
Repeatability | ±0.2%F.S. ±1 digit |
||||
Hysteresis | Hysteresis mode | 0 to variable *1
|
|||
Window comparator mode | |||||
Analogue output | Voltage output *2 | Output Voltage (rated pressure range) | 1 to 5 V ±2.5%F.S. |
0.6 to 5 V ±2.5%F.S. |
|
Linearity | ±1%F.S. |
||||
Output impedance | approx. 1 kΩ; |
||||
Current output *3 | Output current (rated pressure range) | 4 to 20 mA ±2.5%F.S. |
2.4 to 20 mA ±2.5%F.S. |
||
Linearity | ±1%F.S. |
||||
Load impedance | Max. load impedance: 300 Ω (at power supply voltage of 12 VDC); 600 Ω (at power supply voltage of 24 VDC)
Min. load impedance: 50 Ω |
||||
Auto-shift input | Non-voltage input (reed or solid state), Low level 0.4 V or less, input times 5 ms or more |
||||
Display method | 3 1/2digits 7-segment display, Dual-color display (red/green) |
||||
Indicator accuracy | ±2%F.S. ±1 digit (at ambient temperature 25±3 °C) |
||||
Indication light | Light when ON OUT1, OUT2: Orange |
||||
Environment | Enclosure | IP65 |
|||
Ambient temperature range | Operation: 0 to 50 °C, Storage: -10 to 60 °C (no condensation or freezing) |
||||
Ambient humidity range | Operation, Storage: 35 to 85%RH (no condensation) |
||||
Withstand voltage | 1000 VAC, 1 minute between lead block and case |
||||
Insulation resistance | 50 MΩ or more at 500 VDC between lead block and case |
||||
Temperature characteristics | ±2%F.S. (25 °C reference) |
||||
Lead wire | Oil resistant vinyl cabtyre cable 5 cores: φ3.5, 2 m; Sectional area of conductor: 0.15 mm2 (AWG26); Outside diameter of insulator: 1.0 mm |
||||
Standard | CE, UL/CSA, RoHS |
||||
*1: If the applied voltage fluctuates around the set value, the hysteresis more than the fluctuating width needs to be set. Otherwise, chattering will occur. *2: If analog voltage output is selected, the analog current output cannot be selected at the same time. *3: If analog current output is selected, the analog voltage output cannot be selected at the same time. |
Model No. | 01 |
N01 |
W1 |
WF1 |
M5 |
C4 |
C6 |
|
Port size | R1/8 (with M5 female thread) |
NPT1/8 (with M5 female thread) |
Rc1/8 |
G1/8 |
M5x0.8 (Female) |
One-touch fitting φ4 |
One-touch fitting φ6 |
|
Wetted part material | Pressure sensing part | Silicone |
||||||
Piping port | C3602 (Electro less nickel plating) O-ring: HNBR |
ZDC2 O-ring: HNBR |
ZDC2, POM, SUS304, C304 (Electro less nickel plating) O-ring: HNBR |
|||||
Weight | 78 g |
79 g |
97 g |
97 g |
104 g |
101 g |
101 g |
Model No. | ZSE40A (vacuum) |
ISE40A (positive pressure) |
|
Rated pressure range | 0 to -101.3 kPa |
-0.100 to 1.000 MPa |
|
Set pressure range | 10.0 to -105.0 kPa |
-0.105 to 1.050 MPa |
|
Withstand pressure | 500 kPa |
1.5 MPa |
|
Minimum display unit | 0.1 kPa |
0.001 MPa |
|
Applicable fluid | Air, inert gases and incombustible gases |
||
Power supply voltage | 12 to 24 VDC ±10%, ripple (p-p) 10% or less (protected against reverse connection) |
||
Current consumption | 45 mA or less |
||
Switch output | NPN or PNP open collector 1 output |
||
Max. load current | 80 mA |
||
Max. applied voltage | 28 V (NPN output) |
||
Residual voltage | 1 V or less (at 80 mA load current) |
||
Response time | 2.5 ms or less (with anti-chatter function: 20, 100, 500, 1000 or 2000 ms) |
||
Short circuit protection | Provided |
||
Repeatability | ±0.2%F.S. ±1 digit |
||
Hysteresis | Hysteresis mode | 0 to variable *1
|
|
Window comparator mode | |||
Display | 3 1/2digits, 7-segment, dual-colour display (red/green) |
||
Display accuracy | ±2% F.S. ±1 digit (at ambient temperature 25±3 °C) |
||
Indicator LED | LED is ON when output is ON OUT: Orange |
||
Environment | Enclosure | IP65 |
|
Operating temperature range | Operation: -5 to 50 °C Storage: -10 to 60 °C (no condensation or freezing) |
||
Operating humidity range | Operation, Storage: 35 to 85% RH (no condensation) |
||
Withstand voltage | 1000 VAC, 1 minute between terminals and housing |
||
Insulation resistance | 50 MΩ or more at 500 VDC between terminals and housing |
||
UL Temperature rating | Surrounding air temperature rating: Maximum 50 °C |
||
Temperature characteristics | ±2% F.S. (25 °C reference) |
||
Standard | CE, UL/CSA, RoHS |
||
*1: If the applied voltage fluctuates around the set value, the hysteresis must be set to more than the fluctuation width. Otherwise, chattering will occur. |
Model No. | 01 |
N01 |
|
Port size | R1/8 (with M5 female thread) |
NPT1/8 (with M5 female thread) |
|
Material of wetted parts | Pressure sensing part | Silicone |
|
Piping port | C3602 (electroless nickel plating) O-ring: HNBR |
||
Weight | 45 g |
46 g |