- All Products
- Shop by Brands
- BW Technologies
- BW Technologies
- BW Technologies Monitors
- Models
- BW Clip
- BW Clip4
- GasAlertClip Extreme
- GasAlert Extreme
- GasAlertMicroClip XT
- GasAlertMicroClip XL
- GasAlertMicroClip X3
- GasAlertQuattro
- GasAlertMax XT II
- GasAlertMicro 5 Series
- SamplerPak
- IntelliDox Docking System
- MicroDock II
- BW Ultra
- BW Solo
- Gas Monitors
- Gas Monitor Manufacturers
- BW Technologies
- Bacharach
- Biosystems
- Crowcon
- Gas Clip Technologies
- GfG Instruments
- GMI/Detcon
- Honeywell Analytics
- Industrial Scientific
- MSA
- RAE Instruments
- RKI Instruments
- Calibration Gas
- Combustion Analyzers
- Water Quality
- Reliability Instruments
- Refractometers
- HVAC
- Weather
- Temperature
- Laboratory
- Sound
- IAQ
- Electrical
- All Categories
Hanna Nitrate, High Range, Portable Photometer - HI96786
Item #:
HI96786
Brand:
Hanna Instruments
Share this product:
HI96786 Nitrate, High Range, Portable Photometer by Hanna Instruments
Nitrates are present in nature as a result of decomposition of organic microorganisms or due to their use as fertilizers. Nitrates reduce to nitrites, which in turn easily combine to form substances dangerous to man.
A maximum level of 45 mg/L (ppm) is established as a worldwide guideline for nitrate concentration in water. In Europe, the maximum consented level of nitrates in potable water is 50.0 mg/L (ppm), while in the USA the EPA has established a guideline for the maximum level of nitrate—nitrogen of 10 mg/L (NO-3-N), which corresponds to 45.0 mg/L of nitrates.
The HI 96786 meter measures the nitrate content in water and wastewater.
This meter uses an exclusive positive-locking system to ensure that the cuvette is in the same place every time it is placed into the measurement cell.
- CAL CHECK™
- User calibration
- Certified calibration and verification standards
- BEPS (Battery Error Prevention System)
- TIMER function
- Auto shut-off
- GLP Features
Order Information:
HI 96786 are supplied with sample cuvettes with caps (2), 9V battery and instruction manual.
HI 9786C include photometer, sample cuvettes with caps (2 ea.), 9V battery, scissors, cloth for wiping cuvettes, instrument quality certificate, instruction manual and rigid carrying case.
Range | 0.0 to 100 mg/L |
Resolution | 1 mg/L |
Accuracy @ 25°C | ±5 mg/L ±5% of reading |
Light Source | Tungsten lamp |
Light Detector | silicon photocell with narrow band interference filter @ 525 nm |
Power Supply | 9V battery |
Auto-off | after ten minutes of non-use in measurement mode; after one hour of non-use in calibration mode; with last reading reminder |
Environment | 0 to 50°C (32 to 122°F); RH max 95% non-condensing |
Dimensions | 192 x 104 x 69 mm (7.6 x 4.1 x 2.7") |
Weight | 360 g (12.7 oz.) |
Method | adaptation of cadmium reaction method |