- All Products
- Shop by Brands
- BW Technologies
- BW Technologies
- BW Technologies Monitors
- Models
- BW Clip
- BW Clip4
- GasAlertClip Extreme
- GasAlert Extreme
- GasAlertMicroClip XT
- GasAlertMicroClip XL
- GasAlertMicroClip X3
- GasAlertQuattro
- GasAlertMax XT II
- GasAlertMicro 5 Series
- SamplerPak
- IntelliDox Docking System
- MicroDock II
- BW Ultra
- BW Solo
- Gas Monitors
- Gas Monitor Manufacturers
- BW Technologies
- Bacharach
- Biosystems
- Crowcon
- Gas Clip Technologies
- GfG Instruments
- GMI/Detcon
- Honeywell Analytics
- Industrial Scientific
- MSA
- RAE Instruments
- RKI Instruments
- Calibration Gas
- Combustion Analyzers
- Water Quality
- Reliability Instruments
- Refractometers
- HVAC
- Weather
- Temperature
- Laboratory
- Sound
- IAQ
- Electrical
- All Categories
Hanna Ammonia Medium Range Portable Photometer - HI96715
Item #:
HI96715
Brand:
Hanna Instruments
Share this product:
HI96715 Ammonia Medium Range Portable Photometer by Hanna Instruments
The HI 96715 meter measures the ammonia-nitrogen (NH3-N) content in water samples.
These meters use an exclusive positive-locking system to ensure that the cuvette is in the same place every time it is placed into the measurement cell.
Ammonia is often an excellent indication of the presence of animal or plant microbiological decay. It is tested in fish farms (fresh and salt water tanks) due to the damaging effects of its toxic nature. Its presence in rivers and reservoirs normally points to agricultural and/or civil pollutants. Ammonia is tested in lakes, rivers, portable water, boiler feed water, sewage, industrial and waste water.
- CAL CHECK™
- User calibration
- Certified calibration and verification standards
- BEPS (Battery Error Prevention System)
- TIMER function
- Auto shut-off
- GLP Features
Order Information:
HI 96715 is supplied with sample cuvettes with caps (2), 9V battery and instruction manual.
HI 96715C includes photometer, sample cuvettes with caps (2 ea.), 9V battery, cloth for wiping cuvettes, instrument quality certificate, instruction manual and rigid carrying case.
Range | 0.00 to 9.99 mg/L (ppm) |
Resolution | 0.01 mg/L (ppm) |
Accuracy | ±0.05 mg/L ±5% of reading @ 25°C |
Light Detector | Silicon Photocell with narrow band interference filter @ 466 nm |
Light Source | Light Emitting Diode |
Environment | 0 to 50°C (32 to 122°F); Max 95% RH non-condensing |
Battery Type | 9V |
Auto Shut-off | after ten minutes of non-use in measurement mode; after one hour of non-use in calibration mode; with last reading reminder |
Dimensions | 192 x 104 x 69 mm (7.6 x 4.1 x 2.7") |
Weight | 360 g (12.7 oz.) |
Method | adaptation of the ASTM Manual of Water and Environmental Technology, D1426-92, Nessler method |