- All Products
- Shop by Brands
- BW Technologies
- BW Technologies
- BW Technologies Monitors
- Models
- BW Clip
- BW Clip4
- GasAlertClip Extreme
- GasAlert Extreme
- GasAlertMicroClip XT
- GasAlertMicroClip XL
- GasAlertMicroClip X3
- GasAlertQuattro
- GasAlertMax XT II
- GasAlertMicro 5 Series
- SamplerPak
- IntelliDox Docking System
- MicroDock II
- BW Ultra
- BW Solo
- Gas Monitors
- Gas Monitor Manufacturers
- BW Technologies
- Bacharach
- Biosystems
- Crowcon
- Gas Clip Technologies
- GfG Instruments
- GMI/Detcon
- Honeywell Analytics
- Industrial Scientific
- MSA
- RAE Instruments
- RKI Instruments
- Calibration Gas
- Combustion Analyzers
- Water Quality
- Reliability Instruments
- Refractometers
- HVAC
- Weather
- Temperature
- Laboratory
- Sound
- IAQ
- Electrical
- All Categories
Hanna Ammonia Low Range Portable Photometer - HI96700
Item #:
HI96700
Brand:
Hanna Instruments
Share this product:
HI96700 Ammonia Low Range Portable Photometer by Hanna Instruments
The HI 96700 meter measures the ammonia-nitrogen (NH3-N) content in water samples.
These meters use an exclusive positive-locking system to ensure that the cuvette is in the same place every time it is placed into the measurement cell.
Ammonia is often an excellent indication of the presence of animal or plant microbiological decay. It is tested in fish farms (fresh and salt water tanks) due to the damaging effects of its toxic nature. Its presence in rivers and reservoirs normally points to agricultural and/or civil pollutants. Ammonia is tested in lakes, rivers, portable water, boiler feed water, sewage, industrial and waste water.
- CAL CHECK™
- User calibration
- Certified calibration and verification standards
- BEPS (Battery Error Prevention System)
- TIMER function
- Auto shut-off
- GLP Features
Order Information:
HI 96700 is supplied with sample cuvettes with caps (2), 9V battery and instruction manual.
HI 96700C includes photometer, sample cuvettes with caps (2 ea.), 9V battery, cloth for wiping cuvettes, instrument quality certificate, instruction manual and rigid carrying case.
Range | 0.00 to 3.00 mg/L (ppm) |
Resolution | 0.01 mg/L (ppm) |
Accuracy | ±0.04 mg/L (ppm) ±4% of reading @ 25°C |
Light Source | Tungsten lamp |
Light Detection | silicon photocell with narrow band interference filter @ 420 nm |
Environment | 0 to 50°C (32 to 122°F); RH max 95% non-condensing |
Power Supply | 9V battery |
Auto-off | After 10 minutes of non-use in measuring mode After 1 hour of non-use in calibration mode with last reading reminder |
Dimensions | 192 x 104 x 69 mm (7.6 x 4.1 x 2.7") |
Weight | 360 g (12.7 oz.) |
Method | Adaptation of the ASTM Manual of Water and Environmental Technology, D1426-92, Nessler method. |