- All Products
- Shop by Brands
- BW Technologies
- BW Technologies
- BW Technologies Monitors
- Models
- BW Clip
- BW Clip4
- GasAlertClip Extreme
- GasAlert Extreme
- GasAlertMicroClip XT
- GasAlertMicroClip XL
- GasAlertMicroClip X3
- GasAlertQuattro
- GasAlertMax XT II
- GasAlertMicro 5 Series
- SamplerPak
- IntelliDox Docking System
- MicroDock II
- BW Ultra
- BW Solo
- Gas Monitors
- Gas Monitor Manufacturers
- BW Technologies
- Bacharach
- Biosystems
- Crowcon
- Gas Clip Technologies
- GfG Instruments
- GMI/Detcon
- Honeywell Analytics
- Industrial Scientific
- MSA
- RAE Instruments
- RKI Instruments
- Calibration Gas
- Combustion Analyzers
- Water Quality
- Reliability Instruments
- Refractometers
- HVAC
- Weather
- Temperature
- Laboratory
- Sound
- IAQ
- Electrical
- All Categories
Hanna Silica, High Range, Portable Photometer - HI96770
Item #:
HI96770
Brand:
Hanna Instruments
Share this product:
HI96770 Silica, High Range, Portable Photometer by Hanna Instruments
Silica is found in all natural waters in the dissolved mineral form. Silica is only slightly soluble in water; solubility and therefore the form of silica in water depends on the pH level of the water and on the minerals containing silica in contact with water.
Silica’s presence in industrial applications is undesirable since it causes scale. In particular, high pressure turbines are highly effected by this factor.
Heating systems and reverse osmosis plants also require monitoring of silica.
HI 96770 measures silica (SiO2) content from 0 to 200 mg/L.
- CAL CHECK™
- User calibration
- Certified calibration and verification standards
- BEPS (Battery Error Prevention System)
- TIMER function
- Auto shut-off
- GLP Features
Order Information:
HI 96770 are supplied with sample cuvettes with caps (2 ea.), battery and instructions.
HI 96770C includes photometer, sample cuvettes with caps (2 ea.), 9V battery, scissors, cloth for wiping cuvettes, instrument quality certificate, instruction manual and rigid carrying case.
Range | 0 to 200 mg/L (as SiO2) |
Resolution | 1 mg/L |
Accuracy | ±1 mg/L ±5% of reading @ 25°C |
Light Source | light emitting diode |
Light Detection | Silicon Photocell with narrow band interference filter @ 466 nm. |
Method | adaptation of the USEPA METHOD 370.1 for drinking, surface and saline waters, domestic and industrial wastes and Standard Method 4500-SiO2 C |
Environment | 0 to 50°C (32 to 122°F); max 95% RH non-condensing |
Power Supply | 9V battery |
Auto Shut-off | after ten minutes of non-use in measurement mode; after one hour of non-use in calibration mode; with last reading reminder |
Dimensions | 192 x 104 x 69 mm (7.6 x 4.1 x 2.7") |
Weight | 360 g (12.7 oz.) |