- All Products
- Shop by Brands
- BW Technologies
- BW Technologies
- BW Technologies Monitors
- Models
- BW Clip
- BW Clip4
- GasAlertClip Extreme
- GasAlert Extreme
- GasAlertMicroClip XT
- GasAlertMicroClip XL
- GasAlertMicroClip X3
- GasAlertQuattro
- GasAlertMax XT II
- GasAlertMicro 5 Series
- SamplerPak
- IntelliDox Docking System
- MicroDock II
- BW Ultra
- BW Solo
- Gas Monitors
- Gas Monitor Manufacturers
- BW Technologies
- Bacharach
- Biosystems
- Crowcon
- Gas Clip Technologies
- GfG Instruments
- GMI/Detcon
- Honeywell Analytics
- Industrial Scientific
- MSA
- RAE Instruments
- RKI Instruments
- Calibration Gas
- Combustion Analyzers
- Water Quality
- Reliability Instruments
- Refractometers
- HVAC
- Weather
- Temperature
- Laboratory
- Sound
- IAQ
- Electrical
- All Categories
Hanna Chlorine, Total Low Range, Portable Photometer Kit - HI96761C
Item #:
HI96761C
Brand:
Hanna Instruments
Share this product:
HI96761C Chlorine, Total Low Range, Portable Photometer Kit by Hanna Instruments
The HI 96761 meter measures the traces of total chlorine (Cl2) content in drinking water samples.
This meter uses an exclusive positive-locking system to ensure that the cuvette is in the same place every time it is placed into the measurement cell.
Chlorine is integrated into water supplies in it’s molecular form for the purpose of destroying unwanted microorganisms. Once introduced to the water, chlorine will form into three different forms; free chlorine, hypochlorous acid, and hypochlorous ions. Free chlorine will combine itself with ammonia and nitrogen compounds, creating combined chlorine. When chlorine and ammonia combine, it creates chloramines (monochloramine, dichloramine, and nitrogen trichloride. Proper testing should be administered when chlorinating any water supply, as potentially harmful compounds such as chloroform may be formed. N, N-diethyl-p-phenylenediamine (DPD) as well as other methods are available for measuring total residual chlorine.
- CAL CHECK™
- User calibration
- Certified calibration and verification standards
- BEPS (Battery Error Prevention System)
- TIMER function
- Auto shut-off
- GLP Features
Order Information:
HI 96761 is supplied with sample cuvettes with caps (2), 9V battery and instruction manual.
HI 96761C includes photometer, sample cuvettes with caps (2 ea.), 9V battery, scissors, cloth for wiping cuvettes, instrument quality certificate, instruction manual and rigid carrying case.
Range | 0.000 to 0.500 mg/L |
Resolution | 0.001 mg/L |
Accuracy | ±0.020 mg/L ±3% of reading @ 25°C |
Light Source | Tungsten lamp |
Light Detector | Silicon photocell with narrow band interference filter @ 525 nm |
Power Supply | 9V battery |
Auto-off | After 10 minutes of non-use in measurement mode; after 1 hour of non-use in calibration mode; with last reading reminder. |
Environment | 0 to 50°C (32 to 122°F); RH max 95% non-condensing |
Dimensions | 192 x 104 x 69 mm (7.6 x 4.1 x 2.7") |
Weight | 360 g (12.7 oz.) |
Method | adaptation of the USEPA method 330.5 and Standard Method 4500-Cl G |