- All Products
- Shop by Brands
- BW Technologies
- BW Technologies
- BW Technologies Monitors
- Models
- BW Clip
- BW Clip4
- GasAlertClip Extreme
- GasAlert Extreme
- GasAlertMicroClip XT
- GasAlertMicroClip XL
- GasAlertMicroClip X3
- GasAlertQuattro
- GasAlertMax XT II
- GasAlertMicro 5 Series
- SamplerPak
- IntelliDox Docking System
- MicroDock II
- BW Ultra
- BW Solo
- Gas Monitors
- Gas Monitor Manufacturers
- BW Technologies
- Bacharach
- Biosystems
- Crowcon
- Gas Clip Technologies
- GfG Instruments
- GMI/Detcon
- Honeywell Analytics
- Industrial Scientific
- MSA
- RAE Instruments
- RKI Instruments
- Calibration Gas
- Combustion Analyzers
- Water Quality
- Reliability Instruments
- Refractometers
- HVAC
- Weather
- Temperature
- Laboratory
- Sound
- IAQ
- Electrical
- All Categories
Hanna Chlorine, Total Hardness, Iron LR and pH Portable Photometer - HI96745
Item #:
HI96745
Brand:
Hanna Instruments
Share this product:
HI96745 Chlorine, Total Hardness, Iron LR and pH Portable Photometer by Hanna Instruments
Chlorine and pH are two of the most closely monitored parameters in water quality tests. Hardness is also an important parameter, attentively regulated to reduce waste or ensure proper functioning of equipment. Iron can cause an unpleasant taste or stain kitchenware or laundry.
The HI 96745 is a powerful instrument to keep all these parameters under control. The reagents are in liquid or powder form and are supplied in bottles or in packets.
The cuvette has a very important role because it is an optical element and thus requires particular attention. It is important that both the measurement and calibration (zeroing) cuvettes, are optically identical to provide the same measuring conditions.
- CAL CHECK™
- User calibration
- Certified calibration and verification standards
- BEPS (Battery Error Prevention System)
- TIMER function
- Auto shut-off
- GLP Features
Order Information:
HI 96745 is supplied with sample cuvettes (2) with caps, battery and instructions.
Range | pH: 6.5 to 8.5 pH Chlorine: 0.00 to 5.00 mg/L (ppm) Total Hardness: 0.00 to 4.70 mg/L (ppm) Iron LR: 0 to 1.60 mg/L (ppm) |
Resolution | pH: 0.1 pH Chlorine: 0.01 mg/L under 3.50 mg/L; 0.10 mg/L above 3.50 mg/L Total Hardness: 0.01 mg/L Iron LR: 0.01 mg/L |
Accuracy @25°C | pH: ±0.1 pH Chlorine: ±0.03 mg/L ±3% of reading Total Hardness: ±0.11 mg/L ±5% of reading Iron LR: ±0.01 mg/L ±8% of reading |
Light Source | tungsten lamp |
Light Detector | silicon photocell with narrow band interference filter @ 525 nm |
Power Supply | 9V battery |
Auto-off | after ten minutes of non-use in measurement mode; after one hour of non-use in calibration mode; with last reading reminder. |
Environment | 0 to 50°C (32 to 122°F); RH max 95% non-condensing |
Dimensions | 192 x 104 x 69 mm (7.6 x 4.1 x 2.7") |
Weight | 360 g (12.7 oz.) |
Method | pH: Phenol Red method Chlorine: adaptation of the USEPA method 330.5and Standard Method 4500-Cl G Total Hardness: adaptation of the Standard Methods for the examination of Water and Wastewater, 18th ed., colorimetric method Iron LR: adaptation of the TPTZ method |