- All Products
- Shop by Brands
- BW Technologies
- BW Technologies
- BW Technologies Monitors
- Models
- BW Clip
- BW Clip4
- GasAlertClip Extreme
- GasAlert Extreme
- GasAlertMicroClip XT
- GasAlertMicroClip XL
- GasAlertMicroClip X3
- GasAlertQuattro
- GasAlertMax XT II
- GasAlertMicro 5 Series
- SamplerPak
- IntelliDox Docking System
- MicroDock II
- BW Ultra
- BW Solo
- Gas Monitors
- Gas Monitor Manufacturers
- BW Technologies
- Bacharach
- Biosystems
- Crowcon
- Gas Clip Technologies
- GfG Instruments
- GMI/Detcon
- Honeywell Analytics
- Industrial Scientific
- MSA
- RAE Instruments
- RKI Instruments
- Calibration Gas
- Combustion Analyzers
- Water Quality
- Reliability Instruments
- Refractometers
- HVAC
- Weather
- Temperature
- Laboratory
- Sound
- IAQ
- Electrical
- All Categories
Hanna Bromine, Chlorine, Cyanuric Acid, Iron Iodine and pH Portable Photometer - HI96101
Item #:
HI96101
Brand:
Hanna Instruments
Share this product:
HI96101 Bromine, Chlorine, Cyanuric Acid, Iron Iodine and pH Portable Photometer by Hanna Instruments
The HI 96101 measures Bromine, Free and Total Chlorine, Cyanuric Acid, Iron, Iodine and pH content in water and wastewater samples. The reagents are in powder and liquid form depending on the parameter and they are supplied in dropper bottles and packets.
This multiparameter photometer can save time and money. If you need a simple, but professional meter measuring the most important constituents of water, especially in pools and spas, then HI 96101 has been designed for you.
The meter uses an exclusive positive-locking system to ensure that the cuvette is in the same place every time it is placed into the measurement cell.
The cuvette has a very important role because it is an optical element and thus requires particular attention. It is important that both the measurement and calibration (zeroing) cuvettes are optically identical to provide the same measuring conditions.
- CAL CHECK™
- User calibration
- Certified calibration and verification standards
- BEPS (Battery Error Prevention System)
- TIMER function
- Auto shut-off
- GLP Features
Order Information:
HI 96101 is supplied with sample cuvettes (2) with caps, 9V battery and instruction manual.
HI 96101C includes HI 96101 photometer, hard carrying case, 2 sample cuvettes, scissors, cuvette cleaning cloth, battery and instruction manual
Range | Bromine: 0.00 to 10.00 mg/L (ppm) Cl, Free: 0.00 to 5.00 mg/L (ppm) Cl, Total: 0.00 to 5.00 mg/L (ppm) CYA: 0 to 80 mg/L (ppm) Iodine: 0.0 to 12.5 mg/L (ppm) Iron LR: 0.00 to 1.60 mg/L pH: 6.5 to 8.5 pH |
Resolution | Bromine: 0.01 mg/L (ppm) Chlorine: 0.01 mg/L under 3.50 mg/L; 0.10 mg/L above 3.50 mg/L CYA: 1 mg/L (ppm) Iron LR: 0.01 mg/L pH: 0.1 pH |
Accuracy @25°C | Bromine: ±0.08 mg/L ±3% of reading Chlorine: ±0.03 mg/L ±3% of reading CYA: ±1 mg/L ±15% of reading Iodine: ±0.1 mg/L ±5% of reading Iron LR: ±0.01 mg/L ±8% of reading pH: ±0.1 pH |
Light Source | tungsten lamp |
Light Detector | silicon photocell with narrow band interference filter @ 525 nm |
Power Supply | 9V battery |
Auto-off | after ten minutes of non-use in measurement mode; after one hour of non-use in calibration mode; with last reading reminder |
Dimensions | 192 x 104 x 69 mm (7.6 x 4.1 x 2.7") |
Weight | 360 g (12.7 oz.) |
Method | Bromine: adaptation of the EPA, DPD method Chlorine: Adaptation of the USEPA method and Standard Method 4500-Cl G CYA: adaptation of the turbidimetric method Iodine: adaptation of the EPA, DPD method Iron LR: adaptation of the TPTZ method pH: Phenol Red method |
Environment | 0 to 50°C (32 to 122°F); RH max 95% non-condensing |