1-866-4 JJSTECH(1-866-455-7832)

Hanna Chlorine, Cyanuric Acid and pH Portable Photometer Kit for Legionella Protection - HI96725C

Item #:
HI96725C
Brand:
Hanna Instruments
Hanna Chlorine, Cyanuric Acid and pH Portable Photometer Kit for Legionella Protection - HI96725C
$540.00
Qty

Discontinued

Send This Page to a Friend

Ask an Expert

Our tech experts are ready to help!

1-866-4 JJSTECH (1-866-455-7832)

Email Us
Share this product:
Hanna Chlorine, Cyanuric Acid and pH Portable Photometer Kit for Legionella Protection - HI96725C

Hanna Chlorine, Cyanuric Acid and pH Portable Photometer Kit for Legionella Protection - HI96725C

$540.00

Discontinued


HI96725C Chlorine, Cyanuric Acid and pH Portable Photometer Kit for Legionella Protection by Hanna Instruments

Legionella species is the agent that causes human Legionnaires' disease as well as the lesser form, Pontiac Fever. Transmission is facilitated by the inhalation of mist droplets containing the Legionella bacteria.

Common sources of Legionella include cooling towers used in industrial cooling water systems as well as in large central air conditioning systems, domestic hot water systems, fountains, and similar disseminators that draw from a public water supply. Natural sources include freshwater ponds and creeks.

Since Legionella is especially harmful to people with weakened immune systems, it should be actively checked for in the water systems of hospitals and nursing homes.

The HI 96725 measures 4 parameters that are crucial in monitoring for preventive maintenance or disinfection.

  • CAL CHECK™
  • User calibration
  • Certified calibration and verification standards
  • BEPS (Battery Error Prevention System)
  • TIMER function
  • Auto shut-off
  • GLP Features

Order Information:

HI 96725 is supplied with sample cuvettes (2) with caps, 9V battery and instruction manual.
HI 96725C includes HI 96725 photometer, hard carrying case, 2 sample cuvettes, scissors, cuvette cleaning cloth, battery and instruction manual.

Range Cl, Free: 0.00 to 5.00 mg/L (ppm)
Cl, Total: 0.00 to 5.00 mg/L (ppm)
CYA: 0 to 80 mg/L (ppm)
pH: 6.5 to 8.5 pH
Resolution Cl, Free: 0.01 mg/L
Cl, Total: 0.01 mg/L
CYA: 1 mg/L (ppm)
pH: 0.1 pH
Accuracy @25°C Cl, Free: ±0.03 mg/L ±3% of reading
Cl, Total: ±0.03 mg/L ±3% of reading
CYA: ±1 mg/L ±15% of reading
pH: ±0.1 pH
Light Source tungsten lamp
Light Detector silicon photocell with narrow band interference filter @ 525 nm
Power Supply 9V battery
Auto-off after ten minutes of non-use in measurement mode; after one hour of non-use in calibration mode; with last reading reminder
Environment 0 to 50°C (32 to 122°F); RH max 95% non-condensing
Dimensions 192 x 104 x 69 mm (7.6 x 4.1 x 2.7")
Weight 360 g (12.7 oz.)
Method Chlorine: adaptation of the EPA recommended DPD method 330.5
CYA: adaptation of the Turbidimetric method
pH: Phenol Red method