- All Products
- Shop by Brands
- BW Technologies
- BW Technologies
- BW Technologies Monitors
- Models
- BW Clip
- BW Clip4
- GasAlertClip Extreme
- GasAlert Extreme
- GasAlertMicroClip XT
- GasAlertMicroClip XL
- GasAlertMicroClip X3
- GasAlertQuattro
- GasAlertMax XT II
- GasAlertMicro 5 Series
- SamplerPak
- IntelliDox Docking System
- MicroDock II
- BW Ultra
- BW Solo
- Gas Monitors
- Gas Monitor Manufacturers
- BW Technologies
- Bacharach
- Biosystems
- Crowcon
- Gas Clip Technologies
- GfG Instruments
- GMI/Detcon
- Honeywell Analytics
- Industrial Scientific
- MSA
- RAE Instruments
- RKI Instruments
- Calibration Gas
- Combustion Analyzers
- Water Quality
- Reliability Instruments
- Refractometers
- HVAC
- Weather
- Temperature
- Laboratory
- Sound
- IAQ
- Electrical
- All Categories
Hanna Iron, Low Range and Manganese Low Range Portable Photometer - HI96742
Item #:
HI96742
Brand:
Hanna Instruments
Share this product:
HI96742 Iron, Low Range and Manganese Low Range Portable Photometer by Hanna Instruments
Neither iron nor manganese are considered dangerous, but high concentrations of these metals in water can create a bittersweet or astringent taste.
The presence of iron in supplied water is undesirable due to the staining effect on laundry and porcelain.
Manganese, in high concentrations, can produce corrosion and scaling in pipes, which is a serious industrial concern.
The solution for these applications is the HANNA HI 96742, a hand-held photometer to measure low range iron and manganese.
- CAL CHECK™
- User calibration
- Certified calibration and verification standards
- BEPS (Battery Error Prevention System)
- TIMER function
- Auto shut-off
- GLP Features
Order Information:
HI 96742 are supplied with sample cuvettes with caps (2), 9V battery and instruction manual.
Range | Iron LR: 0 to 1.60 mg/L (ppm) Manganese LR: 0 to 300 µg/L |
Resolution | Iron LR: 0.01 mg/L Manganese LR: 1 µg/L |
Accuracy @25°C | Iron LR: ±0.01 mg/L ±8% of reading Manganese LR: ±2 µg/L ±3% of reading |
Light Source | tungsten lamp |
Light Detector | silicon photocell with narrow band interference filter @ 525 nm |
Power Supply | 9V battery |
Auto-off | after ten minutes of non-use in measurement mode; after one hour of non-use in calibration mode; with last reading reminder. |
Dimensions | 192 x 104 x 69 mm (7.6 x 4.1 x 2.7") |
Environment | 0 to 50°C (32 to 122°F); RH max 95% non-condensing |
Weight | 360 g (12.7 oz.) |
Method | Iron LR: adaptation of TPTZ method Manganese LR: adaptation of the 1-(2-pyridylazo)-2-naphthol PAN method |