- All Products
- Shop by Brands
- BW Technologies
- BW Technologies
- BW Technologies Monitors
- Models
- BW Clip
- BW Clip4
- GasAlertClip Extreme
- GasAlert Extreme
- GasAlertMicroClip XT
- GasAlertMicroClip XL
- GasAlertMicroClip X3
- GasAlertQuattro
- GasAlertMax XT II
- GasAlertMicro 5 Series
- SamplerPak
- IntelliDox Docking System
- MicroDock II
- BW Ultra
- BW Solo
- Gas Monitors
- Gas Monitor Manufacturers
- BW Technologies
- Bacharach
- Biosystems
- Crowcon
- Gas Clip Technologies
- GfG Instruments
- GMI/Detcon
- Honeywell Analytics
- Industrial Scientific
- MSA
- RAE Instruments
- RKI Instruments
- Calibration Gas
- Combustion Analyzers
- Water Quality
- Reliability Instruments
- Refractometers
- HVAC
- Weather
- Temperature
- Laboratory
- Sound
- IAQ
- Electrical
- All Categories
Hanna Nickel, Low Range, Portable Photometer - HI96740
Item #:
HI96740
Brand:
Hanna Instruments
Share this product:
HI96740 Nickel, Low Range, Portable Photometer by Hanna Instruments
Nickel is commonly utilized by the electroplating industry in processes utilizing stainless steel, cobalt or nickel alloys.
Nickel is also used in batteries, fuel cells and hydrogenation of vegetable oils in the food industry.
The HI 96740 meter measures the Nickel content in water and wastewater. This meter uses an exclusive positive-locking system to ensure that the cuvette is in the same place every time it is placed into the measurement cell.
The cuvette has a very important role because it is an optical element and thus requires particular attention. It is important that both, the measurement and the calibration (zeroing) cuvettes, are optically identical to provide the same measurement conditions.
- CAL CHECK™
- User calibration
- Certified calibration and verification standards
- BEPS (Battery Error Prevention System)
- TIMER function
- Auto shut-off
- GLP Features
Order Information:
HI 96740 is supplied with sample cuvettes with caps (2), 9V battery and instruction manual.
HI 96740C include photometer, sample cuvettes with caps (2 ea.), 9V battery, scissors, cloth for wiping cuvettes, instrument quality certificate, instruction manual and rigid carrying case.
Range | 0.000 to 1.000 mg/L |
Resolution | 0.001 mg/L |
Accuracy | ±0.010 mg/L ±7% of reading @ 25°C |
Light Source | Tungsten Lamp |
Light Detection | silicon photocell with narrow band interference filter @ 575 nm |
Battery Type / Life | 1 x 9V / approx. 40 hours of continuous use; auto-off after 10 minutes of non use |
Environment | 0 to 50°C (32 to 122°F); RH max 95% non-condensing |
Dimensions | 192 x 104 x 69 mm (7.6 x 4.1 x 2.7") |
Weight | 360 g (12.7 oz.) |
Method | Adaptation of the PAN method |