- All Products
- Shop by Brands
- BW Technologies
- BW Technologies
- BW Technologies Monitors
- Models
- BW Clip
- BW Clip4
- GasAlertClip Extreme
- GasAlert Extreme
- GasAlertMicroClip XT
- GasAlertMicroClip XL
- GasAlertMicroClip X3
- GasAlertQuattro
- GasAlertMax XT II
- GasAlertMicro 5 Series
- SamplerPak
- IntelliDox Docking System
- MicroDock II
- BW Ultra
- BW Solo
- Gas Monitors
- Gas Monitor Manufacturers
- BW Technologies
- Bacharach
- Biosystems
- Crowcon
- Gas Clip Technologies
- GfG Instruments
- GMI/Detcon
- Honeywell Analytics
- Industrial Scientific
- MSA
- RAE Instruments
- RKI Instruments
- Calibration Gas
- Combustion Analyzers
- Water Quality
- Reliability Instruments
- Refractometers
- HVAC
- Weather
- Temperature
- Laboratory
- Sound
- IAQ
- Electrical
- All Categories
Hanna Fluoride, High Range, Portable Photometer Kit - HI96739C
Item #:
HI96739C
Brand:
Hanna Instruments
Share this product:
HI96739C Fluoride, High Range, Portable Photometer Kit by Hanna Instruments
The HI 96739 meter measures the fluoride (F–) content in water, wastewater and seawater in the 0 to 20 mg/L (ppm) range.
This meter uses an exclusive positive-locking system to ensure that the cuvette is in the same position every time it is placed into the measurement cell. It is designed to fit cuvettes with a larger neck making it easier to add both sample and reagents. The cuvettes are made from special optical glass to obtain best results.
- CAL CHECK™
- User calibration
- Certified calibration and verification standards
- BEPS (Battery Error Prevention System)
- TIMER function
- Auto shut-off
- GLP Features
Order Information:
HI 96739 is supplied sample cuvettes with caps (2), 9V battery and instruction manual.
HI 96739C includes sample cuvettes with caps (2 ea.), 2000 µL automatic pipette with instruction sheet, 9V battery, cloth for wiping cuvettes, instrument quality certificate, instruction manual and rigid carrying case.
Range | 0.0 to 20.0 mg/L (ppm) |
Resolution | 0.1 mg/L (ppm) |
Accuracy | ±0.5 mg/L (ppm) ±3% of reading @ 25°C |
Light Source | Tungsten lamp |
Light Detector | Silicon photocell with narrow band interference filter @ 575nm |
Environment | 0 to 50°C (32 to 122°F); RH max 95% non-condensing |
Power Supply | 9V battery |
Auto-off | After 10 minutes of non-use in measurement mode; after 1 hour of non-use in calibration mode; with last reading reminder. |
Dimensions | 192 x 104 x 69 mm (7.6 x 4.1 x 2.7") |
Weight | 360 g (12.7 oz.) |
Method | Adaptation of the SPADNS method. |