- All Products
- Shop by Brands
- BW Technologies
- BW Technologies
- BW Technologies Monitors
- Models
- BW Clip
- BW Clip4
- GasAlertClip Extreme
- GasAlert Extreme
- GasAlertMicroClip XT
- GasAlertMicroClip XL
- GasAlertMicroClip X3
- GasAlertQuattro
- GasAlertMax XT II
- GasAlertMicro 5 Series
- SamplerPak
- IntelliDox Docking System
- MicroDock II
- BW Ultra
- BW Solo
- Gas Monitors
- Gas Monitor Manufacturers
- BW Technologies
- Bacharach
- Biosystems
- Crowcon
- Gas Clip Technologies
- GfG Instruments
- GMI/Detcon
- Honeywell Analytics
- Industrial Scientific
- MSA
- RAE Instruments
- RKI Instruments
- Calibration Gas
- Combustion Analyzers
- Water Quality
- Reliability Instruments
- Refractometers
- HVAC
- Weather
- Temperature
- Laboratory
- Sound
- IAQ
- Electrical
- All Categories
Hanna Hardness, EPA, Portable Photometer - HI96735
Item #:
HI96735
Brand:
Hanna Instruments
Share this product:
HI96735 Hardness, EPA, Portable Photometer by Hanna Instruments
Total hardness, that is the presence of magnesium and calcium, is due mainly to the runoff water dissolving these salts as it flows or filters through different strata. Hardness can also cause scaling of pipes in cooling and heating systems.
The HI 93735 measures the total hardness in drinking, surface and wastewater.
This meter uses an exclusive positive-locking system to ensure that the cuvette is in the same position every time it is placed into the measurement cell. It is designed to fit cuvettes with a larger neck making it easier to add both sample and reagents. The cuvettes are made from special optical glass to obtain best results.
- CAL CHECK™
- User calibration
- Certified calibration and verification standards
- BEPS (Battery Error Prevention System)
- TIMER function
- Auto shut-off
- GLP Features
Order Information:
HI 96735 is supplied with sample cuvettes with caps (2), 9V battery and instruction manual.
Range | LR 0 to 250 mg/L; MR 200 to 500 mg/L; HR 400 to 750 mg/L |
Resolution | 1.0 mg/L from 1 to 100 mg/L; 5.0 mg/Lfrom 100 to 750 mg/L |
Accuracy | LR ±5mg/L ±4% of reading@ 25°C; MR ±7 mg/L ±3% of reading@ 25°C; HR ±10 mg/L ±2% of reading@ 25°C |
Light Source | light emitting diode |
Light Detector | Silicon photocell with narrow band interference filter @ 466 nm |
Method | Adaptation of the EPA recommended method 130.1. |
Environment | 0 to 50°C (32 to 122°F); max 95% RH non-condensing |
Power Supply | 9V battery |
Auto-Shut off | after ten minutes of non-use in measurement mode; after one hour of non-use in calibration mode; with last reading reminder |
Dimensions | 192 x 104 x 69 mm (7.6 x 4.1 x 2.7") |
Weight | 360 g (12.7 oz.) |