- All Products
- Shop by Brands
- BW Technologies
- BW Technologies
- BW Technologies Monitors
- Models
- BW Clip
- BW Clip4
- GasAlertClip Extreme
- GasAlert Extreme
- GasAlertMicroClip XT
- GasAlertMicroClip XL
- GasAlertMicroClip X3
- GasAlertQuattro
- GasAlertMax XT II
- GasAlertMicro 5 Series
- SamplerPak
- IntelliDox Docking System
- MicroDock II
- BW Ultra
- BW Solo
- Gas Monitors
- Gas Monitor Manufacturers
- BW Technologies
- Bacharach
- Biosystems
- Crowcon
- Gas Clip Technologies
- GfG Instruments
- GMI/Detcon
- Honeywell Analytics
- Industrial Scientific
- MSA
- RAE Instruments
- RKI Instruments
- Calibration Gas
- Combustion Analyzers
- Water Quality
- Reliability Instruments
- Refractometers
- HVAC
- Weather
- Temperature
- Laboratory
- Sound
- IAQ
- Electrical
- All Categories
Hanna Zinc Portable Photometer - HI96731
Item #:
HI96731
Brand:
Hanna Instruments
Share this product:
HI96731 Zinc Portable Photometer by Hanna Instruments
Zinc is normally introduced into drinking water through industrial effluents, especially due to dezincification of brass and deterioration of galvanized iron.
In addition to drinking water, zinc is measured in surface finishing, boilers and cooling towers, water conditioning, effluent waters and many others.
The HI 96731 measures the zinc content in water and wastewater in the 0.00 to 3.00 mg/L (ppm) range.
The meter uses an exclusive positive-locking system to ensure that the cuvette is in the same place every time it is placed into the measurement cell.
The cuvette has a very important role because it is an optical element and thus requires particular attention. It is important that both, the measurement and the calibration (zeroing) cuvettes, are optically identical to provide the same measurement conditions.
- CAL CHECK™
- User calibration
- Certified calibration and verification standards
- BEPS (Battery Error Prevention System)
- TIMER function
- Auto shut-off
- GLP Features
Order Information:
HI 96731 is supplied with sample cuvettes with caps (2), 9V battery and instruction manual.
Range | 0.00 to 3.00 mg/L |
Resolution | 0.01 mg/L |
Accuracy | ±0.03 m/L ± 3% of reading @ 25°C |
Light Source | Tungsten lamp |
Light Detector | Silicon photocell with narrow band interference filter @ 575 nm |
Method | adaptation of the Standard Methods for the Examination of Water and Wastewater, 20th edition, Zincon method |
Environment | 0 to 50°C (32 to 122°F); max 95% RH non-condensing |
Battery Type | 1 x 9 volt |
Auto-Shut off | after ten minutes of non-use in measurement mode; after one hour of non-use in calibration mode; with last reading reminder |
Dimensions | 192 x 104 x 69 mm (7.6 x 4.1 x 2.7") |
Weight | 360 g (12.7 oz.) |