- All Products
- Shop by Brands
- BW Technologies
- BW Technologies
- BW Technologies Monitors
- Models
- BW Clip
- BW Clip4
- GasAlertClip Extreme
- GasAlert Extreme
- GasAlertMicroClip XT
- GasAlertMicroClip XL
- GasAlertMicroClip X3
- GasAlertQuattro
- GasAlertMax XT II
- GasAlertMicro 5 Series
- SamplerPak
- IntelliDox Docking System
- MicroDock II
- BW Ultra
- BW Solo
- Gas Monitors
- Gas Monitor Manufacturers
- BW Technologies
- Bacharach
- Biosystems
- Crowcon
- Gas Clip Technologies
- GfG Instruments
- GMI/Detcon
- Honeywell Analytics
- Industrial Scientific
- MSA
- RAE Instruments
- RKI Instruments
- Calibration Gas
- Combustion Analyzers
- Water Quality
- Reliability Instruments
- Refractometers
- HVAC
- Weather
- Temperature
- Laboratory
- Sound
- IAQ
- Electrical
- All Categories
Hanna Fluoride, Low Range, Portable Photometer - HI96729
Item #:
HI96729
Brand:
Hanna Instruments
Share this product:
HI96729 Fluoride, Low Range, Portable Photometer by Hanna Instruments
The HI 96729 meter measures the fluoride (F–) content in the 0.00 to 2.00 mg/L (ppm) range, in drinking, surface and waste waters. The amount of reagent is precisely dosed by use of the supplied automatic pipette for maximum repeatability.
This meter uses an exclusive positive-locking system to ensure that the cuvette is in the same position every time it is placed into the measurement cell. It is designed to fit cuvettes with a larger neck making it easier to add both sample and reagents. The cuvettes are made from special optical glass to obtain best results.
- CAL CHECK™
- User calibration
- Certified calibration and verification standards
- BEPS (Battery Error Prevention System)
- TIMER function
- Auto shut-off
- GLP Features
Order Information:
HI 96729 is supplied sample cuvettes with caps (2), 9V battery and instruction manual.
HI 96729C includes sample cuvettes with caps (2 ea.), 2000 µL automatic pipette with instruction sheet, 9V battery, cloth for wiping cuvettes, instrument quality certificate, instruction manual and rigid carrying case.
Range | 0.00 to 2.00 mg/L (ppm) |
Resolution | 0.01 mg/L (ppm) |
Accuracy | ±0.03 mg/L ±3% 0f reading @ 25°C |
Light Source | tungsten lamp |
Light Detector | silicon photocell with narrow band interference filter @ 575 nm |
Environment | 0 to 50°C (32 to 122°F); Max 95% RH non-condensing |
Power Supply | 9V battery |
Auto Shut-off | after ten minutes of non-use in measurement mode; after one hour of non-use in calibration mode; with last reading reminder |
Dimensions | 192 x 104 x 69 mm (7.6 x 4.1 x 2.7") |
Weight | 360 g (12.7 oz.) |
Method | adaptation of the EPA method 340.1 and Standard Methods for the Examination of Water and Wastewater, 20th edition, SPADNS method |