- All Products
- Shop by Brands
- BW Technologies
- BW Technologies
- BW Technologies Monitors
- Models
- BW Clip
- BW Clip4
- GasAlertClip Extreme
- GasAlert Extreme
- GasAlertMicroClip XT
- GasAlertMicroClip XL
- GasAlertMicroClip X3
- GasAlertQuattro
- GasAlertMax XT II
- GasAlertMicro 5 Series
- SamplerPak
- IntelliDox Docking System
- MicroDock II
- BW Ultra
- BW Solo
- Gas Monitors
- Gas Monitor Manufacturers
- BW Technologies
- Bacharach
- Biosystems
- Crowcon
- Gas Clip Technologies
- GfG Instruments
- GMI/Detcon
- Honeywell Analytics
- Industrial Scientific
- MSA
- RAE Instruments
- RKI Instruments
- Calibration Gas
- Combustion Analyzers
- Water Quality
- Reliability Instruments
- Refractometers
- HVAC
- Weather
- Temperature
- Laboratory
- Sound
- IAQ
- Electrical
- All Categories
Hanna Nitrate, Low Range, Portable Photometer - HI96728
Item #:
HI96728
Brand:
Hanna Instruments
Share this product:
HI96728 Nitrate, Low Range, Portable Photometer by Hanna Instruments
Nitrates are present in nature as a result of decomposition of organic microorganisms or due to their use as fertilizers. Nitrates reduce to nitrites, which in turn easily combine to form substances dangerous to man.
A maximum level of 45 mg/L (ppm) is established as a worldwide guideline for nitrate concentration in water. In Europe, the maximum consented level of nitrates in potable water is 50.0 mg/L (ppm), while in the USA the EPA has established a guideline for the maximum level of nitrate—nitrogen of 10 mg/L (NO-3-N), which corresponds to 45.0 mg/L of nitrates.
The HI 96728 meter measures the nitrate content in water and wastewater.
This meter uses an exclusive positive-locking system to ensure that the cuvette is in the same place every time it is placed into the measurement cell.
- CAL CHECK™
- User calibration
- Certified calibration and verification standards
- BEPS (Battery Error Prevention System)
- TIMER function
- Auto shut-off
- GLP Features
Order Information:
HI 96728 is supplied with sample cuvettes with caps (2), 9V battery and instruction manual.
HI 96728C include photometer, sample cuvettes with caps (2 ea.), 9V battery, scissors, cloth for wiping cuvettes, instrument quality certificate, instruction manual and rigid carrying case.
Range | 0.0 to 30.0 mg/L |
Resolution | 0.1 mg/L |
Accuracy | ±0.5 mg/L ±10% of reading@ 25°C |
Light Source | Tungsten lamp |
Light Detector | Silicon photocell with narrow band interference filter @ 525 nm |
Environment | 0 to 50°C (32 to 122°F); RH max 95% non-condensing |
Power Supply | (1) 9V battery |
Auto-off | After 10 minutes of non-use in measurement mode; after 1 hour of non-use in calibration mode; with last reading reminder. |
Dimensions | 192 x 104 x 69 mm (7.6 x 4.1 x 2.7") |
Weight | 360 g (12.7 oz.) |
Method | Adaptation of the cadmium reduction method. |