- All Products
- Shop by Brands
- BW Technologies
- BW Technologies
- BW Technologies Monitors
- Models
- BW Clip
- BW Clip4
- GasAlertClip Extreme
- GasAlert Extreme
- GasAlertMicroClip XT
- GasAlertMicroClip XL
- GasAlertMicroClip X3
- GasAlertQuattro
- GasAlertMax XT II
- GasAlertMicro 5 Series
- SamplerPak
- IntelliDox Docking System
- MicroDock II
- BW Ultra
- BW Solo
- Gas Monitors
- Gas Monitor Manufacturers
- BW Technologies
- Bacharach
- Biosystems
- Crowcon
- Gas Clip Technologies
- GfG Instruments
- GMI/Detcon
- Honeywell Analytics
- Industrial Scientific
- MSA
- RAE Instruments
- RKI Instruments
- Calibration Gas
- Combustion Analyzers
- Water Quality
- Reliability Instruments
- Refractometers
- HVAC
- Weather
- Temperature
- Laboratory
- Sound
- IAQ
- Electrical
- All Categories
Hanna Ca Hardness, Standard Method, Portable Photometer - HI96720
Item #:
HI96720
Brand:
Hanna Instruments
Share this product:
HI96720 Ca Hardness, Standard Method, Portable Photometer by Hanna Instruments
The HI 96720 measures the calcium hardness content, as CaCO3, in water and wastewater in the 0.00 to 2.70 mg/L (ppm) range.
This meter uses an exclusive positive-locking system to ensure that the cuvette is in the same position every time it is placed into the measurement cell. It is designed to fit cuvettes with a larger neck making it easier to add both sample and reagents. The cuvettes are made from special optical glass to obtain best results.
- CAL CHECK™
- User calibration
- Certified calibration and verification standards
- BEPS (Battery Error Prevention System)
- TIMER function
- Auto shut-off
- GLP Features
Order Information:
HI 96720 is supplied with sample cuvettes with caps (2), 9V battery and instruction manual.
HI 96720C includes photometer, sample cuvettes with caps (2 ea.), 9V battery, 1 mL syringe with tip, cloth for wiping cuvettes, instrument quality certificate, instruction manual, rigid carrying case.
Range | 0.00 to 2.70 mg/L |
Resolution | 0.01 mg/L |
Accuracy | ±0.11 mg/L ±5% of reading @ 25°C |
Light Source | Tungsten lamp |
Light Detector | Silicon photocell with narrow band interference filter @ 525nm |
Method | Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th ed. Calmagite method. |
Environment | 0 to 50°C (32 to 122°F); max 95% RH non-condensing |
Power Supply | 9V battery |
Auto-Shut off | after ten minutes of non-use in measurement mode; after one hour of non-use in calibration mode; with last reading reminder |
Dimensions | 192 x 104 x 69 mm (7.6 x 4.1 x 2.7") |
Weight | 360 g (12.7 oz.) |