- All Products
- Shop by Brands
- BW Technologies
- BW Technologies
- BW Technologies Monitors
- Models
- BW Clip
- BW Clip4
- GasAlertClip Extreme
- GasAlert Extreme
- GasAlertMicroClip XT
- GasAlertMicroClip XL
- GasAlertMicroClip X3
- GasAlertQuattro
- GasAlertMax XT II
- GasAlertMicro 5 Series
- SamplerPak
- IntelliDox Docking System
- MicroDock II
- BW Ultra
- BW Solo
- Gas Monitors
- Gas Monitor Manufacturers
- BW Technologies
- Bacharach
- Biosystems
- Crowcon
- Gas Clip Technologies
- GfG Instruments
- GMI/Detcon
- Honeywell Analytics
- Industrial Scientific
- MSA
- RAE Instruments
- RKI Instruments
- Calibration Gas
- Combustion Analyzers
- Water Quality
- Reliability Instruments
- Refractometers
- HVAC
- Weather
- Temperature
- Laboratory
- Sound
- IAQ
- Electrical
- All Categories
Hanna Cyanide Portable Photometer - HI96714
Item #:
HI96714
Brand:
Hanna Instruments
Share this product:
HI96714 Cyanide Portable Photometer by Hanna Instruments
The HI 96714 meter measures the cyanide concentration in waters. The meter uses an exclusive positive-locking system to ensure that the cuvette is in the same position every time it is placed into the measurement cell. It is designed to fit cuvettes with a larger neck making it easier to add both sample and reagents. The cuvettes are made from special optical glass to obtain best results.
Cyanide is a pollutant that originates mostly from metalurgicaland galvanic industrial plants. Cyanide is poisonous to human nervous system, and it is therefore imperative to monitor and control its level in potable water. Continuous monitoring in waste effluents is required, and cyanide is removed using alkaline chlorination procedure. Due to this, European norm limit the concentration of cyanide in drinking water to 0.05 mg/L, while the EPA has established that the maximum level is not to exceed 0.2 mg/L.
- CAL CHECK™
- User calibration
- Certified calibration and verification standards
- BEPS (Battery Error Prevention System)
- TIMER function
- Auto shut-off
- GLP Features
Order Information:
HI 96714 is supplied with sample cuvettes with caps (2), 9V battery and instruction manual.
Range | 0.000 to 0.200 mg/L |
Resolution | 0.001 mg/L |
Accuracy | ±0.005 mg/L ±3% of reading @ 25°C |
Light Source | Tungsten Lamp |
Light Detection | silicon photocell with narrow band interference filter @ 610 nm |
Battery Type / Life | 9V / approx. 40 hours of continuous use; auto-off after 10 minutes of non use |
Environment | 0 to 50°C (32 to 122°F); RH max 95% non-condensing |
Dimensions | 192 x 104 x 69 mm (7.6 x 4.1 x 2.7") |
Weight | 360 g (12.7 oz.) |
Method | adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, Pyridine-Pyrazolone method |