- All Products
- Shop by Brands
- BW Technologies
- BW Technologies
- BW Technologies Monitors
- Models
- BW Clip
- BW Clip4
- GasAlertClip Extreme
- GasAlert Extreme
- GasAlertMicroClip XT
- GasAlertMicroClip XL
- GasAlertMicroClip X3
- GasAlertQuattro
- GasAlertMax XT II
- GasAlertMicro 5 Series
- SamplerPak
- IntelliDox Docking System
- MicroDock II
- BW Ultra
- BW Solo
- Gas Monitors
- Gas Monitor Manufacturers
- BW Technologies
- Bacharach
- Biosystems
- Crowcon
- Gas Clip Technologies
- GfG Instruments
- GMI/Detcon
- Honeywell Analytics
- Industrial Scientific
- MSA
- RAE Instruments
- RKI Instruments
- Calibration Gas
- Combustion Analyzers
- Water Quality
- Reliability Instruments
- Refractometers
- HVAC
- Weather
- Temperature
- Laboratory
- Sound
- IAQ
- Electrical
- All Categories
Hanna Phosphate, Low Range, Portable Photometer - HI96713
Item #:
HI96713
Brand:
Hanna Instruments
Share this product:
HI96713 Phosphate, Low Range, Portable Photometer by Hanna Instruments
Phosphates are particularly important for the growth and development of plant roots, and hence are one of the most common fertilizers used in agriculture.
Phosphates are also utilized in detergents and are needed, in small quantities, for heating systems. However, high concentrations of phosphates can cause environmental pollution as they are a primary cause of eutrophication.
For these reasons, it is necessary to closely monitor the phosphate levels present in both municipal and industrial waste water.
The HI 96713 measures phosphate (PO43–) content in water, wastewater and seawater in the 0.00 to 2.50 mg/L (ppm) range.
- CAL CHECK™
- User calibration
- Certified calibration and verification standards
- BEPS (Battery Error Prevention System)
- TIMER function
- Auto shut-off
- GLP Features
Order Information:
HI 96713 is supplied with sample cuvettes with caps (2), 9V battery and instruction manual.
HI 96713C includes photometer, sample cuvettes with caps (2 ea.), 9V battery, scissors, cloth for wiping cuvettes, instrument quality certificate, instruction manual and rigid carrying case.
Range | 0.00 to 2.50 mg/L |
Resolution | 0.01 mg/L |
Accuracy | ±0.04 mg/L ± 4% of reading @ 25°C |
Light Source | Tungsten lamp |
Light Detector | Silicon photocell with narrow band interference filter @ 610 nm |
Method | Adaptation of the ascorbic acid method. |
Environment | 0 to 50°C (32 to 122°F); max 95% RH non-condensing |
Battery Type | 9V battery |
Auto-Shut off | after ten minutes of non-use in measurement mode; after one hour of non-use in calibration mode; with last reading reminder |
Dimensions | 192 x 104 x 69 mm (7.6 x 4.1 x 2.7") |
Weight | 360 g (12.7 oz.) |