- All Products
- Shop by Brands
- BW Technologies
- BW Technologies
- BW Technologies Monitors
- Models
- BW Clip
- BW Clip4
- GasAlertClip Extreme
- GasAlert Extreme
- GasAlertMicroClip XT
- GasAlertMicroClip XL
- GasAlertMicroClip X3
- GasAlertQuattro
- GasAlertMax XT II
- GasAlertMicro 5 Series
- SamplerPak
- IntelliDox Docking System
- MicroDock II
- BW Ultra
- BW Solo
- Gas Monitors
- Gas Monitor Manufacturers
- BW Technologies
- Bacharach
- Biosystems
- Crowcon
- Gas Clip Technologies
- GfG Instruments
- GMI/Detcon
- Honeywell Analytics
- Industrial Scientific
- MSA
- RAE Instruments
- RKI Instruments
- Calibration Gas
- Combustion Analyzers
- Water Quality
- Reliability Instruments
- Refractometers
- HVAC
- Weather
- Temperature
- Laboratory
- Sound
- IAQ
- Electrical
- All Categories
Hanna Nitrite, Low Range, Portable Photometer - HI96707
Item #:
HI96707
Brand:
Hanna Instruments
Share this product:
HI96707 Nitrite, Low Range, Portable Photometer by Hanna Instruments
Nitrites are an intermediate product in the nitrogen cycle and are produced by ammonia oxidation with water, or even originate in industrial waste directly. They must not be present in drinking water.
The HI 96707 measures the Nitrogen-Nitrite content in the 0.000 to 0.600 mg/L (ppm) range, in drinking, surface and saline water samples and in domestic and industrial wastes.
This meter uses an exclusive positive-locking system to ensure that the cuvette is in the same place every time it is placed into the measurement cell.
- CAL CHECK™
- User calibration
- Certified calibration and verification standards
- BEPS (Battery Error Prevention System)
- TIMER function
- Auto shut-off
- GLP Features
Order Information:
HI 96707 is supplied with sample cuvettes with caps (2), 9V battery and instruction manual.
HI 96707C includes photometer, sample cuvettes with caps (2 ea.), 9V battery, scissors, cloth for wiping cuvettes, instrument quality certificate, instruction manual and rigid carrying case.
Range | 0.000 to 0.600 mg/L (ppm) |
Resolution | 0.001 mg/L (ppm) |
Accuracy | ±0.020 mg/L ±4% of reading @ 25°C |
Method | adaptation of an EPA approved method |
Light Source | Tungsten lamp |
Light Detector | Silicon Photocell with narrow band interference filter @ 525 nm |
Environment | 0 to 50°C (32 to 122°F);max 95% RH non-condensing |
Power Supply | 9V battery |
Auto-Shut off | after ten minutes of non-use in measurement mode; after one hour of non-use in calibration mode; with last reading reminder |
Dimensions | 192 x 104 x 69 mm (7.6 x 4.1 x 2.7") |
Weight | 360 g (12.7 oz.) |