- All Products
- Shop by Brands
- BW Technologies
- BW Technologies
- BW Technologies Monitors
- Models
- BW Clip
- BW Clip4
- GasAlertClip Extreme
- GasAlert Extreme
- GasAlertMicroClip XT
- GasAlertMicroClip XL
- GasAlertMicroClip X3
- GasAlertQuattro
- GasAlertMax XT II
- GasAlertMicro 5 Series
- SamplerPak
- IntelliDox Docking System
- MicroDock II
- BW Ultra
- BW Solo
- Gas Monitors
- Gas Monitor Manufacturers
- BW Technologies
- Bacharach
- Biosystems
- Crowcon
- Gas Clip Technologies
- GfG Instruments
- GMI/Detcon
- Honeywell Analytics
- Industrial Scientific
- MSA
- RAE Instruments
- RKI Instruments
- Calibration Gas
- Combustion Analyzers
- Water Quality
- Reliability Instruments
- Refractometers
- HVAC
- Weather
- Temperature
- Laboratory
- Sound
- IAQ
- Electrical
- All Categories
Hanna Phosphorous Portable Photometer - HI96706
Item #:
HI96706
Brand:
Hanna Instruments
Share this product:
HI96706 Phosphorous Portable Photometer by Hanna Instruments
Phosphorus is found in nature as phosphates. Its concentration in water is monitored because it causes corrosion when present in high levels. It is also an essential parameter for the growth of microorganisms and algae, which are often unwanted in tanks and reserves of water.
Phosphorus is also an essential element for plant growth and for this reason, is needed in large amounts.
The HI 96706 measures the phosphorus (P) content in water samples in the 0.0 to 15.0 mg/L (ppm) range.
HI 96706 uses an exclusive positive-locking system to ensure that the cuvette is in the same place every time it is placed into the measurement cell.
- CAL CHECK™
- User calibration
- Certified calibration and verification standards
- BEPS (Battery Error Prevention System)
- TIMER function
- Auto shut-off
- GLP Features
Order Information:
HI 96706 is supplied with sample cuvettes with caps (2), 9V battery and instruction manual.
HI 96706C includes photometer, sample cuvettes with caps (2 ea.), 9V battery, scissors, cloth for wiping cuvettes, instrument quality certificate, instruction manual and rigid carrying case.
Range | 0.0 to 15.0 mg/L (ppm) |
Resolution | 0.1 mg/L (ppm) |
Accuracy | ±0.3 mg/L ±4% of reading @ 25°C |
Light Source | Tungsten lamp |
Light Detector | Silicon photocell with narrow band interference filter @ 525 nm |
Environment | 0 to 50°C (32 to 122°F); RH max 95% non-condensing |
Power Supply | (1) 9V battery |
Auto-off | After 10 minutes of non-use in measurement mode; after 1 hour of non-use in calibration mode; with last reading reminder. |
Dimensions | 192 x 104 x 69 mm (7.6 x 4.1 x 2.7") |
Weight | 360 g (12.7 oz.) |
Method | Amino Acid Method, adapted from Standard Method for the Examination of Water and Wastewater |