- All Products
- Shop by Brands
- BW Technologies
- BW Technologies
- BW Technologies Monitors
- Models
- BW Clip
- BW Clip4
- GasAlertClip Extreme
- GasAlert Extreme
- GasAlertMicroClip XT
- GasAlertMicroClip XL
- GasAlertMicroClip X3
- GasAlertQuattro
- GasAlertMax XT II
- GasAlertMicro 5 Series
- SamplerPak
- IntelliDox Docking System
- MicroDock II
- BW Ultra
- BW Solo
- Gas Monitors
- Gas Monitor Manufacturers
- BW Technologies
- Bacharach
- Biosystems
- Crowcon
- Gas Clip Technologies
- GfG Instruments
- GMI/Detcon
- Honeywell Analytics
- Industrial Scientific
- MSA
- RAE Instruments
- RKI Instruments
- Calibration Gas
- Combustion Analyzers
- Water Quality
- Reliability Instruments
- Refractometers
- HVAC
- Weather
- Temperature
- Laboratory
- Sound
- IAQ
- Electrical
- All Categories
Hanna Silica Portable Photometer Kit - HI96705C
Item #:
HI96705C
Brand:
Hanna Instruments
Share this product:
HI96705C Silica Portable Photometer Kit by Hanna Instruments
Silica is found in all natural waters in the dissolved mineral form. Silica is only slightly soluble in water; solubility and therefore the form of silica in water depends on the pH level of the water and on the minerals containing silica in contact with water.
Silica’s presence in industrial applications is undesirable since it causes scale. In particular, high pressure turbines are highly effected by this factor.
Heating systems and reverse osmosis plants also require monitoring of silica.
The HI 96705 meter measures the silica (SiO2) content in water and wastewater in the 0.00 to 2.00 mg/L (ppm) range.
- CAL CHECK™
- User calibration
- Certified calibration and verification standards
- BEPS (Battery Error Prevention System)
- TIMER function
- Auto shut-off
- GLP Features
Order Information:
HI 96705 is supplied with sample cuvettes with caps (2 ea.), battery and instructions.
HI 96705C includes photometer, sample cuvettes with caps (2 ea.), 9V battery, scissors, cloth for wiping cuvettes, instrument quality certificate, instruction manual and rigid carrying case.
Range | 0.00 to 2.00 mg/L (ppm) |
Resolution | 0.01 mg/L (ppm) |
Accuracy | ±0.03 mg/L ±3% of reading @ 25°C |
Light Source | Tungsten lamp |
Light Detector | Silicon photocell with narrow band interference filter @ 610 nm |
Environment | 0 to 50°C (32 to 122°F); RH max 95% non-condensing |
Power Supply | (1) 9V battery |
Auto-off | After 10 minutes of non-use in measuring mode; after 1 hour of non-use in calibration mode |
Dimensions | 192 x 104 x 69 mm (7.6 x 4.1 x 2.7") |
Weight | 360 g (12.7 oz.) |
Method | Adaptation of the ASTM D859 method of the heteropoly blue method |