- All Products
- Shop by Brands
- BW Technologies
- BW Technologies
- BW Technologies Monitors
- Models
- BW Clip
- BW Clip4
- GasAlertClip Extreme
- GasAlert Extreme
- GasAlertMicroClip XT
- GasAlertMicroClip XL
- GasAlertMicroClip X3
- GasAlertQuattro
- GasAlertMax XT II
- GasAlertMicro 5 Series
- SamplerPak
- IntelliDox Docking System
- MicroDock II
- BW Ultra
- BW Solo
- Gas Monitors
- Gas Monitor Manufacturers
- BW Technologies
- Bacharach
- Biosystems
- Crowcon
- Gas Clip Technologies
- GfG Instruments
- GMI/Detcon
- Honeywell Analytics
- Industrial Scientific
- MSA
- RAE Instruments
- RKI Instruments
- Calibration Gas
- Combustion Analyzers
- Water Quality
- Reliability Instruments
- Refractometers
- HVAC
- Weather
- Temperature
- Laboratory
- Sound
- IAQ
- Electrical
- All Categories
Hanna Calibration Check™ Portable pH/ORP Meter - HI9126
Item #:
HI9126
Brand:
Hanna Instruments
Share this product:
HI9126 Calibration Check™ Portable pH/ORP Meter by Hanna Instruments
The HI 9126 includes HANNA‘s exclusive Calibration Check™ technology. Calibration Check™ monitors the pH bulb and reference junction of the electrode every time the instrument is calibrated. In the event of a dirty pH electrode, Calibration Check™ warns users that maintenance may be needed.
Calibrated buffers are continuously displayed in measurement mode to remind users of the instrument’s calibration point. Users can easily determine if readings are taken too far outside the calibration range.
The HI 9126 can store and recall readings at the touch of a button.
HI 9126 utilizes the HI 1230B double junction pH electrode. The double junction helps to minimize junction contamination for consistently accurate results. The HI 9126 can also measure ORP using optional probes.
- pH Calibration Check™
- Electrode condition monitoring
- Measurement store and recall
- Backlit, multi-level LCD display
- Real time clock
- User-selectable calibration reminder
- Tutorial messages displayed on LCD
- BEPS; (Battery Error Prevention System) alerts the user in the event that low battery power could adversely affect readings.
- Battery % displayed on startup.
Order Information:
HI 9126 is supplied with HI 1230B pH electrode, HI 7662 temperature probe, HI 70004 pH 4.01 buffer solution sachet, HI 70007 pH 7.01 buffer sachet, HI 700661 electrode cleaning solution sachet, 100 mL plastic beaker, batteries, instructions and hard carrying case.
pH Range | -2.00 to 16.00 pH |
ORP Range | ±699.9 mV; ±1999 mV |
Temperature Range | -20.0 to 120.0°C / -4.0°F to 248.0°F |
pH Resolution | 0.01 pH |
ORP Resolution | 0.1 mV; 1 mV |
Temperature Resolution | 0.1°C / 0.1 °F |
pH Accuracy @ 20°C | ±0.01 pH |
ORP Accuracy @ 20°C | ±0.2 mV; ±1 mV |
Temperature Accuracy @ 20°C | ±0.4°C/±0.8°F (excluding probe error) |
pH Calibration Check | yes, check of the electrode status during calibration |
pH Calibration | automatic, one or two point with seven memorized buffer values (pH 1.68, 4.01, 6.86, 7.01, 9.18, 10.01, 12.45) + 2 custom buffers |
Offset Calibration | ±1 pH |
Slope Calibration | from 80 to 108% |
Temperature Compensation | automatic or manual, -20 to 120°C (-4 to 248°F) without temperature probe |
pH Electrode | HI 1230B PEI body pH electrode with BNC connector and 1 m (3.3’) cable (included) |
Temperature Probe | HI 7662 stainless steel temperature probe with 1 m (3.3’) cable (included) |
Input Impedance | 1012 Ohms |
Battery Type / Life | 1.5V (3) AAA / approximately 200 hours of continuous use without backlight (50 hours with backlight). auto-off after 20 minutes of non-use (can be disabled) |
Environment | 0 to 50°C (32 to 122°F); RH max 100% |
Dimensions | 185 x 72 x 36 mm (7.3 x 2.8 x 1.4”) |
Weight | 300 g (10.6 oz.) |