HI83205-01 Multiparameter Photometer for Boilers and Cooling Towers, 115V by Hanna Instruments

HI 83205 is a multiparameter bench meter that measures twenty-four methods essential for monitoring boiling and cooling towers. It has four channels allowing for a wide range of tests.

With just one unit, technicians can keep an eye on 24 methods needed for proper and efficient functioning of their systems. The parameters that HI?83205 monitors include: iron, whose presence can be an important indication of corrosion; chlorine to circumvent microbiological fouling; dissolved oxygen, whose presence causes corrosion; silica can point to a contamination of the feed water while phosphate is important to reduce scaling.

The optical system of HI 83205 is based on special subminiature tungsten lamps and narrow-band interference filters to guarantee both high performance and reliable results.

HI 83205 has a powerful interactive user support that assists the user during the analysis process. A full tutorial is available in the Setup Menu, and the Help Menu provides assistance for every step in the measurement process. This meter can be connected to a PC via a USB cable, where the data can be managed with optional HI 92000 Windows® compatible software.

  • Light blocking cuvette holder
  • Backlit LCD
  • BEPS (Battery Error Prevention System) Alerts users in the event a low battery could effect readings
  • PC compatible via USB
  • Powered by rechargeable batteries or 12 VDC
  • Save and recall logged data at the touch of a button.
  • On-screen tutorial; with the tutorial function enabled, short guides relating to current operation are displayed.
  • HELP button; screen specific help can viewed at the touch of a button.
  • Method selection; users can easily select parameters via the Method button.
  • Setup button; instrument preferences such as backlight intensity and screen contrast can be changed via the setup button.

Order Information:

HI 83205-01 (115V) and HI 83205-02 (230V) are supplied sample cuvettes and caps (2 ea.), cloth for wiping cuvettes, 60 mL glass bottle for dissolved oxygen analysis, scissors, AC/DC power adapter, and instruction manual.

Light Source up to 5 tungsten lamps with different narrow band interference filters
Light Detector silicon photocell
Environment 0 to 50°C (32 to 122°F); max 90% RH non-condensing
Power Supply external 12 VDC power adapter or built-in rechargeable battery
Dimensions 235 x 200 x 110 mm (9.2 x 7.87 x 4.33")
Weight 0.9 Kg (2 lbs.)
Multi Parameter Specifications
Parameter Range Method Reagent Code
Aluminum 0.00 to 1.00 mg/L (ppm) Aluminon HI 93712-01
Ammonia LR 0.00 to 3.00 mg/L (ppm) Nessler HI 93700-01
Ammonia MR 0.00 to 10.00 mg/L (ppm) Nessler HI 93715-01
Bromine 0.00 to 8.00 mg/L (ppm) DPD HI 93716-01
Chlorine Dioxide 0.00 to 2.00 mg/L (ppm) Chlorophenol Red HI 93738-01
Chlorine, Free 0.00 to 2.50 mg/L (ppm) DPD HI 93701-01
Chlorine, Total 0.00 to 3.50 mg/L (ppm) DPD HI 93711-01
Chromium VI HR 0 to 1000 µg/L Diphenyl-
carbohydrazide
HI 93723-01
Chromium VI LR 0 to 300 µg/L Diphenyl-
carbohydrazide
HI 93749-01
Copper HR 0.00 to 5.00 mg/L (ppm) Bicinchoninate HI 93702-01
Copper LR 0 to 1000 µg/L Bicinchoninate HI 95747-01
Hydrazine 0 to 400 µg/L p-Dimethyl-
aminobenzaldehyde
HI 93704-01
Iron HR 0.00 to 5.00 mg/L (ppm) Phenantroline HI 93721-01
Iron LR 0 to 400 µg/L TPTZ HI 93746-01
Molybdenum 0.0 to 40.0 mg/L (ppm) Mercaptoacetic Acid HI 93730-01
Nitrate 0.0 to 30.0 mg/L (ppm) Cadmium Reduction HI 93728-01
Nitrite HR 0 to 150 mg/L (ppm) Ferrous Sulfate HI 93708-01
Nitrite LR 0.00 to 0.35 mg/L (ppm) Diazotization HI 93707-01
Oxygen,
Dissolved (DO)
0.0 to 10.0 mg/L (ppm) Winkler HI 93732-01
pH 6.5 to 8.5 pH Phenol red HI 93710-01
Phosphate HR 0.0 to 30.0 mg/L (ppm) Amino Acid HI 93717-01
Phosphate LR 0.00 to 2.50 mg/L (ppm) Ascorbic Acid HI 93713-01
Silica 0.00 to 2.00 mg/L (ppm) Heteropoly blue HI 93705-01
Zinc 0.00 to 3.00 mg/L (ppm) Zincon HI 93731-01