- All Products
- Shop by Brands
- BW Technologies
- BW Technologies
- BW Technologies Monitors
- Models
- BW Clip
- BW Clip4
- GasAlertClip Extreme
- GasAlert Extreme
- GasAlertMicroClip XT
- GasAlertMicroClip XL
- GasAlertMicroClip X3
- GasAlertQuattro
- GasAlertMax XT II
- GasAlertMicro 5 Series
- SamplerPak
- IntelliDox Docking System
- MicroDock II
- BW Ultra
- BW Solo
- Gas Monitors
- Gas Monitor Manufacturers
- BW Technologies
- Bacharach
- Biosystems
- Crowcon
- Gas Clip Technologies
- GfG Instruments
- GMI/Detcon
- Honeywell Analytics
- Industrial Scientific
- MSA
- RAE Instruments
- RKI Instruments
- Calibration Gas
- Combustion Analyzers
- Water Quality
- Reliability Instruments
- Refractometers
- HVAC
- Weather
- Temperature
- Laboratory
- Sound
- IAQ
- Electrical
- All Categories
Honeywell Analytics FS7 Multi-Spectrum Fire and Flame Detector, 20FT CBL 72IN TFLN VITON 1 RLY - FS7-2173-RP
Item #:
FS7-2173-RP
Brand:
Honeywell Analytics
Share this product:
FS7-2173-RP FS7 Multi-Spectrum Fire and Flame Detector, 20FT CBL 72IN TFLN VITON 1 RLY by Honeywell Analytics
The Fire Sentry FS7-2173 electro-optical radiant energy fire detector - and the Fire Sentry FS7-2173-2RP (unitized model) with multi-spectral WideBand IR™, Near Band IR and Visible Band fire detection are designed specifically for semiconductor Clean Room fire protection applications.
The Fire Sentry FS7 fire detector provides and intelligent two-stage response to semiconductor wet bench fires:
Stage 1: Alert. This is the first-stage response to a small fire with a heat energy output of 3 kW (the equivalent of a 4-inch diameter polypropylene pool fire). This allows time for the fire to self-extinguish.
Stage 2: Alarm. If the fire does not self-extinguish, and grows to the Factory Mutual specified heat energy threshold of 13 kW (the equivalent of an 8-inch diameter polypropylene pool fire), the second-stage response is activated.
The Fire Sentry FS7-2173 is used with Fire Sentry FS7-130-SX Controller or Control Panel FSWB. Controller and Control Panel supply power to detectors monitor the status of all detectors and communicate with the detectors via the digital RS-485 communication channel. Fire Sentry FS7-2173 is supplied with a standard 20 ft. cable connector. Detectors are connected to the controller or control panel using the self-locking connectors and Fire Sentry junction boxes. This allows for fast and easy connections eliminating wiring problems. Each detector can store up to six time and date stamped FirePics™ (pre-event multi-spectral sensor array data) in non-volatile memory. Controller and control panel can also store event history table in the non-volatile memory, which contains the time and date stamped alert, alarm and fault histories. FirePics™ and event histories can be retrieved from the controller or control panel.
Fire Sentry FS7-2173-2RP unitized model's microprocessor, with digital signal processing algorithms, continuously monitors the circuitry, sensor's built-in selftest and verifies proper operation. Fire Sentry FS7-2173-2RP with discrete relay outputs is designed to operate as a stand-alone detector and interface with any approved fire alarm panel. The detector requires an external 24 VDC power source and is supplied with a standard 20 ft. pigtail cable. It can store up to six time and date stamped FirePics™ and 200 events in non-volatile memory. FirePics™ and event histories can be retrieved using a Fire Sentry FS7 Interface Kit and the Fire Sentry Windows-based PC software.
Features:
- Multi-Spectral digital electro-optical radiant energy infrared fire detector
- Unique two-stage fire detection response
- Immune to false alarm sources
- NOT affected by absorbing smoke, gasses or chemical vapors
- NOT sensitive to background radiant energy from electric heaters and ovens
- Detects hydrocarbon and non-hydrocarbon fires
- Rugged leak-proof, heat-sealed, acid-resistant, injection-molded polypropylene housing
- Wide 120° field-of-view
- Digital communication with RS-485 interface
- FirePic™; time and date-stamped digital fire signatures
- Built-in detector automatic self test
- Unitzed model design for stand-alone operation
Applications include:
- Open Areas of Clean Room
- Wet Bench Working Surface
- Wet Bench Subsurface (Plenum)
- Pumps and Equipment Located Behind the Wet Bench Area
- Under-floor Areas
- IPA Stations (Unitized model only)
Field of View | 120° horizontal and vertica |
Response Time | Alert: 4" dia. Polypropylene pool fire (3kW) within 5 seconds Alarm: 8" dia. dia. Polypropylene pool fire (13kW) within 5 seconds |
Spectral Sensitivity | Visible: 400 - 900 nanometers Near Band IR: 0.7 - 1.1 microns Wide Band IR: 0.7 - 3.5 microns |
Operating Voltage | 24 VDC nominal (18-28 VDC) - Regulated |
Power Consumption | Operating: 55 mA @ 24 VDC nominal Alarm: 80 mA @ 24 VDC nominal |
Output Relays | Alert: SPST, N.O., De-Energized Fire Alarm: SPDT (NO / NC) - De-Energized/Energized, Latching/Non-Latching Fault: SPST (NO) - Normally Energized, Latching/Non-Latching Contacts rating: 1 amp @ 24 VDC |
Communication | RS-485, FireBus II |
Visual Indication | Red LED |
Temperature Range | Operating: 32 to +158°F (0 to 70°C) |
Humidity Range | 10 to 90% relative humidity, non-condensing |
Enclosure Materials | Dust tight, watertight, heat sealed, injection-molded polypropylene |
Enclosure Type | IP67 |
Certifications | FM 3260, FM 3600, FM 3611 CSFM Listed (California State Fire Marshall) |
Shipping Weight | 3 lbs. |
Mounting | Chassis mount slide bracket |
Warranty | Two years from date of shipping |