1-866-4 JJSTECH(1-866-455-7832)

Honeywell Analytics FS7 Multi-Spectrum Fire and Flame Detector, Non-Latching Alert and Alarm Relays, Kal-rez O-ring - FS7-2173-2RP-K

Item #:
FS7-2173-2RP-K
Brand:
Honeywell Analytics
Honeywell Analytics FS7 Multi-Spectrum Fire and Flame Detector, Non-Latching Alert and Alarm Relays, Kal-rez O-ring - FS7-2173-2RP-K
$3,373.00
Qty
Send This Page to a Friend

Ask an Expert

Our tech experts are ready to help!

1-866-4 JJSTECH (1-866-455-7832)

Email Us
Share this product:
Honeywell Analytics FS7 Multi-Spectrum Fire and Flame Detector, Non-Latching Alert and Alarm Relays, Kal-rez O-ring - FS7-2173-2RP-K

Honeywell Analytics FS7 Multi-Spectrum Fire and Flame Detector, Non-Latching Alert and Alarm Relays, Kal-rez O-ring - FS7-2173-2RP-K

$3,373.00

FS7-2173-2RP-K FS7 Multi-Spectrum Fire and Flame Detector, Non-Latching Alert and Alarm Relays, Kal-rez O-ring by Honeywell Analytics

The Fire Sentry FS7-2173 electro-optical radiant energy fire detector - and the Fire Sentry FS7-2173-2RP (unitized model) with multi-spectral WideBand IR™, Near Band IR and Visible Band fire detection are designed specifically for semiconductor Clean Room fire protection applications.

The Fire Sentry FS7 fire detector provides and intelligent two-stage response to semiconductor wet bench fires:

Stage 1: Alert. This is the first-stage response to a small fire with a heat energy output of 3 kW (the equivalent of a 4-inch diameter polypropylene pool fire). This allows time for the fire to self-extinguish.

Stage 2: Alarm. If the fire does not self-extinguish, and grows to the Factory Mutual specified heat energy threshold of 13 kW (the equivalent of an 8-inch diameter polypropylene pool fire), the second-stage response is activated.

The Fire Sentry FS7-2173 is used with Fire Sentry FS7-130-SX Controller or Control Panel FSWB. Controller and Control Panel supply power to detectors monitor the status of all detectors and communicate with the detectors via the digital RS-485 communication channel. Fire Sentry FS7-2173 is supplied with a standard 20 ft. cable connector. Detectors are connected to the controller or control panel using the self-locking connectors and Fire Sentry junction boxes. This allows for fast and easy connections eliminating wiring problems. Each detector can store up to six time and date stamped FirePics™ (pre-event multi-spectral sensor array data) in non-volatile memory. Controller and control panel can also store event history table in the non-volatile memory, which contains the time and date stamped alert, alarm and fault histories. FirePics™ and event histories can be retrieved from the controller or control panel.

Fire Sentry FS7-2173-2RP unitized model's microprocessor, with digital signal processing algorithms, continuously monitors the circuitry, sensor's built-in selftest and verifies proper operation. Fire Sentry FS7-2173-2RP with discrete relay outputs is designed to operate as a stand-alone detector and interface with any approved fire alarm panel. The detector requires an external 24 VDC power source and is supplied with a standard 20 ft. pigtail cable. It can store up to six time and date stamped FirePics™ and 200 events in non-volatile memory. FirePics™ and event histories can be retrieved using a Fire Sentry FS7 Interface Kit and the Fire Sentry Windows-based PC software.

Features:

  • Multi-Spectral digital electro-optical radiant energy infrared fire detector
  • Unique two-stage fire detection response
  • Immune to false alarm sources
  • NOT affected by absorbing smoke, gasses or chemical vapors
  • NOT sensitive to background radiant energy from electric heaters and ovens
  • Detects hydrocarbon and non-hydrocarbon fires
  • Rugged leak-proof, heat-sealed, acid-resistant, injection-molded polypropylene housing
  • Wide 120° field-of-view
  • Digital communication with RS-485 interface
  • FirePic™; time and date-stamped digital fire signatures
  • Built-in detector automatic self test
  • Unitzed model design for stand-alone operation

Applications include:

  • Open Areas of Clean Room
  • Wet Bench Working Surface
  • Wet Bench Subsurface (Plenum)
  • Pumps and Equipment Located Behind the Wet Bench Area
  • Under-floor Areas
  • IPA Stations (Unitized model only)
Field of View 120° horizontal and vertica
Response Time Alert: 4" dia. Polypropylene pool fire (3kW) within 5 seconds
Alarm: 8" dia. dia. Polypropylene pool fire (13kW) within 5 seconds
Spectral Sensitivity Visible: 400 - 900 nanometers
Near Band IR: 0.7 - 1.1 microns
Wide Band IR: 0.7 - 3.5 microns
Operating Voltage 24 VDC nominal (18-28 VDC) - Regulated
Power Consumption Operating: 55 mA @ 24 VDC nominal
Alarm: 80 mA @ 24 VDC nominal
Output Relays Alert: SPST, N.O., De-Energized
Fire Alarm: SPDT (NO / NC) - De-Energized/Energized, Latching/Non-Latching
Fault: SPST (NO) - Normally Energized, Latching/Non-Latching
Contacts rating: 1 amp @ 24 VDC
Communication RS-485, FireBus II
Visual Indication Red LED
Temperature Range Operating: 32 to +158°F (0 to 70°C)
Humidity Range 10 to 90% relative humidity, non-condensing
Enclosure Materials Dust tight, watertight, heat sealed, injection-molded polypropylene
Enclosure Type IP67
Certifications FM 3260, FM 3600, FM 3611
CSFM Listed (California State Fire Marshall)
Shipping Weight 3 lbs.
Mounting Chassis mount slide bracket
Warranty Two years from date of shipping