- All Products
- Shop by Brands
- BW Technologies
- BW Technologies
- BW Technologies Monitors
- Models
- BW Clip
- BW Clip4
- GasAlertClip Extreme
- GasAlert Extreme
- GasAlertMicroClip XT
- GasAlertMicroClip XL
- GasAlertMicroClip X3
- GasAlertQuattro
- GasAlertMax XT II
- GasAlertMicro 5 Series
- SamplerPak
- IntelliDox Docking System
- MicroDock II
- BW Ultra
- BW Solo
- Gas Monitors
- Gas Monitor Manufacturers
- BW Technologies
- Bacharach
- Biosystems
- Crowcon
- Gas Clip Technologies
- GfG Instruments
- GMI/Detcon
- Honeywell Analytics
- Industrial Scientific
- MSA
- RAE Instruments
- RKI Instruments
- Calibration Gas
- Combustion Analyzers
- Water Quality
- Reliability Instruments
- Refractometers
- HVAC
- Weather
- Temperature
- Laboratory
- Sound
- IAQ
- Electrical
- All Categories
Extech MN16A Digital Mini MultiMeter
Item #:
EXT-MN16A
Brand:
Extech
Share this product:
MN16A Digital Mini MultiMeter by Extech
Features
- Large easy to read digital display
- Thermocouple Type K function for surface and air temperature measurements up to 1400°F (760°C)
- Measure AC and DC Voltage to 600V
- DC Current function to 10A
- Resistance tests with Continuity and Diode functions
- Convenient mini size with tilt stand
- Includes built-in tilt stand, 9V battery (MN15A), two AAA batteries (MN16A), Test leads, and general purpose Type K thermocouple probe
- AC Current, Capacitance, Frequency and Duty Cycle measurements
- Data Hold locks reading in the display
Diode Test | Test current of 0.3mA typical, open circuit voltage 1.5V DC typical |
Continuity Check | Audible signal will sound if the resistance is less than 150Ω (approx.), test current <0.3mA |
Temperature Sensor | Requires type K thermocouple |
Input Impedance | 7.8MΩ |
AC Response | Average responding |
ACV Bandwidth | 50Hz to 400Hz |
Display | 4,000 count liquid crystal |
Overrange indication | "OL" is displayed |
Auto Power Off | 30 minutes (approximately) |
Polarity | Automatic (no indication for positive); Minus (-) sign for negative |
Measurement Rate | 2 times per second, nominal |
Low Battery Indication | Battery symbol is displayed if battery voltage drops below operating voltage |
Battery | Two AAA batteries |
Fuses | mA, µA ranges; 0.5A/250V ceramic fast blow A range; 10A/250V ceramic fast blow |
Operating Temperature | 41°F to 104°F (5°C to 40°C) |
Storage Temperature | -4°F to 140°F (-20°C to 60°C) |
Operating Humidity | Max 80% up to 87°F (31°C) decreasing linearly to 50% at 104°F (40°C) |
Storage Humidity | <80% |
Operating Altitude | 7000ft. (2000meters) maximum |
Weight | 0.5lb (225g) (includes holster). |
Size | 5.31" x 2.67" x 1.7" (135 x 68 x 43mm) |
Safety | This meter is intended for indoor use and protected, against the users, by double insulation per EN61010-1 and IEC61010-1 2nd Edition (2001) to CAT III 600V; Pollution Degree 2. The meter also meets UL 61010-1, Second Edition (2004), CAN/CSA C22.2 No. 61010-1, Second Edition (2004), and UL 61010B-2-031, First Edition (2003) |
Approvals | CE, ETL |
Function |
Range |
Resolution |
Accuracy |
DC Voltage (V DC) |
4V |
0.001V |
±(1.2% reading + 2 digits) |
40V |
0.01V |
||
400V |
0.1V |
||
600V |
1V |
±(1.5% reading + 2 digits) |
|
AC Voltage (V AC) (50 / 60Hz) |
400mV |
0.1mV |
±(1.5% reading + 15 digits) |
4V |
0.001V |
±(1.2% reading + 3 digits) |
|
40V |
0.01V |
±(1.5% reading + 3 digits) |
|
400V |
0.1V |
||
600V |
1V |
±(2.0% reading + 4 digits) |
|
*400mV range is not autoranging |
|||
DC Current (A DC) |
400μA |
0.1μA |
±(1.0% reading + 3 digits) |
4000μA |
1μA |
±(1.5% reading + 3 digits) |
|
40mA |
0.01mA |
||
400mA |
0.1mA |
||
10A |
0.01A |
±(2.5% reading + 5 digits) |
|
AC Current (A AC) |
400μA |
0.1μA |
±(1.5% reading + 5 digits) |
4000μA |
1μA |
±(1.8% reading + 5 digits) |
|
40mA |
0.01mA |
||
400mA |
0.1mA |
||
10A |
0.01A |
±(3.0% reading + 7 digits) |
|
Resistance |
400Ω |
0.1Ω |
±(1.2% reading + 4 digits) |
4kΩ |
1Ω |
±(1.0% reading + 2 digits) |
|
40kΩ |
0.01kΩ |
±(1.2% reading + 2 digits) |
|
400kΩ |
0.1kΩ |
||
4MΩ |
0.001MΩ |
||
40MΩ |
0.01MΩ |
±(2.0% reading + 3 digits) |
|
Capacitance |
40nF |
0.01nF |
±(5.0% reading + 30 digits) |
400nF |
0.1nF |
±(3.0% reading + 5 digits) |
|
4μF |
0.001μF |
||
40μF |
0.01μF |
||
100μF |
0.1μF |
±(5.0% reading + 5 digits) |
|
Duty Cycle |
0.1 to 99.9% |
0.1% |
±(1.2% reading + 2 digits) |
pulse width range: 100µs - 100ms (Frequency: 5Hz to 150kHz) |
|||
Temp (type-K) |
-4 to 1400°F |
1°F |
±(3.0% reading + 9°F/5°C) (probe accuracy not included) |
-20 to 750°C |
1°C |
||
Frequency |
5.000Hz |
0.001Hz |
±(1.5% reading + 5 digits) |
50.00Hz |
0.01Hz |
||
500.0Hz |
0.1Hz |
±(1.2% reading + 3 digits) |
|
5.000kHz |
0.001kHz |
||
50.00kHz |
0.01kHz |
||
500.0kHz |
0.1kHz |
||
5.000MHz |
0.001MHz |
±(1.5% reading + 4 digits) |
|
Sensitivity: >0.5V rms min. [ 1MHz; >3V rms > 1MHz |