- All Products
- Shop by Brands
- BW Technologies
- BW Technologies
- BW Technologies Monitors
- Models
- BW Clip
- BW Clip4
- GasAlertClip Extreme
- GasAlert Extreme
- GasAlertMicroClip XT
- GasAlertMicroClip XL
- GasAlertMicroClip X3
- GasAlertQuattro
- GasAlertMax XT II
- GasAlertMicro 5 Series
- SamplerPak
- IntelliDox Docking System
- MicroDock II
- BW Ultra
- BW Solo
- Gas Monitors
- Gas Monitor Manufacturers
- BW Technologies
- Bacharach
- Biosystems
- Crowcon
- Gas Clip Technologies
- GfG Instruments
- GMI/Detcon
- Honeywell Analytics
- Industrial Scientific
- MSA
- RAE Instruments
- RKI Instruments
- Calibration Gas
- Combustion Analyzers
- Water Quality
- Reliability Instruments
- Refractometers
- HVAC
- Weather
- Temperature
- Laboratory
- Sound
- IAQ
- Electrical
- All Categories
Extech MN15A Digital Mini MultiMeter
Item #:
EXT-MN15A
Brand:
Extech
Share this product:
MN15A Digital Mini MultiMeter by Extech
Features
- Large easy to read digital display
- Thermocouple Type K function for surface and air temperature measurements up to 1400°F (760°C)
- Measure AC and DC Voltage to 600V
- DC Current function to 10A
- Resistance tests with Continuity and Diode functions
- Convenient mini size with tilt stand
- Includes built-in tilt stand, 9V battery (MN15A), two AAA batteries (MN16A), Test leads, and general purpose Type K thermocouple probe
- 9V and 1.5V Battery test under load
Diode Test | Bias voltage: 2.8VDC typical |
Continuity Check | Audible signal will sound if the resistance is less than 100Ω |
Input Impedance | 1MΩ (VDC & VAC) |
AC Bandwidth | 50 / 60Hz |
Display | 2000 count (0 to 1999) LCD |
Overrange indication | "1__" is displayed |
Polarity | Automatic (no indication for positive); Minus (-) sign for negative |
Measurement Rate | 2 times per second, nominal |
Low Battery Indication | Battery symbol is displayed |
Batteries | One (1) 9V battery (NEDA 1604) |
Fuses | mA range; 200mA/250V ceramic fast blow A range; 10A/250V ceramic fast blow |
Operating Temperature | 32°F to 122°F (0°C to 50°C) |
Storage Temperature | -4°F to 140°F (-20°C to 60°C) |
Operating Humidity | Max 70% up to 87°F (31°C) decreasing linearly to 50% at 122°F (50°C) |
Storage Humidity | <80% RH |
Operating Altitude | 7000ft. (2000meters) maximum. |
Weight | 9.17 oz (255g) |
Size | 5.2" x 2.6" x 1.5" (132 x 66 x 38mm) |
Approvals | CE, ETL |
Safety | This meter is intended for indoor use and protected, against the users, by double insulation per EN61010-1 and IEC61010- 1 2nd Edition (2001) to CAT III 600V; Pollution Degree 2. The meter also meets UL 61010-1, Second Edition (2004), CAN/CSA C22.2 No. 61010-1, Second Edition (2004), and UL 61010B-2-031, First Edition (2003) |
Function |
Range |
Resolution |
Accuracy |
DC Voltage (V DC) |
200mV |
0.1mV |
±(0.5% reading + 2 digits) |
2000mV |
1mV |
||
20V |
0.01V |
||
200V |
0.1V |
±(0.8% reading + 2 digits) |
|
600V |
1V |
||
AC Voltage (V AC) |
200V |
0.1V |
±(1.2% reading + 10 digits) (50/60Hz) |
600V |
1V |
||
DC Current (A DC) |
200mA |
0.1mA |
±(1.2% reading + 2 digits) |
10A |
10mA |
±(2.0% reading + 2 digits) |
|
Resistance |
200Ω |
0.1Ω |
±(0.8% reading + 2 digits) |
2000Ω |
1Ω |
||
20kΩ |
0.01kΩ |
||
200kΩ |
0.1kΩ |
||
20MΩ |
10kΩ |
±(1.5% reading + 2 digits) |
|
Battery Test |
9V |
10mV |
±(1.0% reading + 2 digits) |
1.5V |
1mV |
||
Temperature |
-20°C to 750°C |
1°C |
±(3% of reading +5°C/9°F) |
-4°F to 1400°F |
1°F |