1-866-4 JJSTECH(1-866-455-7832)

Extech MA435T 400A True RMS AC/DC Clamp Meter + NCV

Item #:
EXT-MA435T
Brand:
Extech
Extech MA435T 400A True RMS AC/DC Clamp Meter + NCV
$129.99
Qty

Discontinued

Send This Page to a Friend

Ask an Expert

Our tech experts are ready to help!

1-866-4 JJSTECH (1-866-455-7832)

Email Us
Share this product:
Extech MA435T 400A True RMS AC/DC Clamp Meter + NCV

Extech MA435T 400A True RMS AC/DC Clamp Meter + NCV

$129.99

Discontinued


MA435T 400A True RMS AC/DC Clamp Meter + NCV by Extech

Compact size allows measurements in tight locations and Built-in non-contact Voltage detector with LED alert. Three models to choose from with True RMS option and advanced multimeter functions.

Features

  • Built-in non-contact Voltage detector with LED alert
  • Backlit LCD display
  • 1.2" (30mm) jaw size for conductors up to 350MCM
  • True RMS models for MA430T/MA435T and multimeter functions included on all clamp meters
  • CAT III - 600V rating
  • Data Hold
  • Low battery indication and Auto Power Off
  • Complete with test leads, general purpose Type K bead wire temperature probe (for MA435T), 9V battery, and soft case
General Specifications
Clamp jaw opening 30mm (1.18") approx.
Display 4,000 count LCD
Continuity check Threshold <150Ω; Test current < 0.5mA
Diode test Test current of 0.3mA typical;
Open circuit voltage [ 1.5VDC typical
Low Battery indication Battery symbol is displayed
Over-range indication 'OL' displayed
Display rate 2 readings per second, nominal
Thermocouple sensor Type K thermocouple required
Input Impedance 10MΩ (VDC and VAC)
AC bandwidth 50 to 400Hz (VAC)
AC response True RMS
Operating Temperature 5°C to 40°C (41°F to 104°F)
Storage Temperature -20°C to 60°C (-4°F to 140°F)
Operating Humidity Max 80% up to 31°C (87°F) decreasing linearly to 50% at 40°C (104°F)
Storage Humidity <80%
Operating Altitude 2000meters (7000ft) maximum.
Battery 9V battery
Auto power OFF After approx. 30 minutes
Dimensions & Weight 200x66x37mm (7.9x2.6x1.5"); 205g (7.23oz)
Safety For indoor use and in accordance with the requirements for double insulation to IEC1010-1 (2001): EN61010-1 (2001) Overvoltage Category III 600V, Pollution Degree 2.
Approvals CE

Range Specifications
Function
Range
Resolution
Accuracy (% of reading + digits)
AC Current 50/60Hz TRMS
40.00 A
0.01A
±(2.8% + 8 digits)
400.0 A
0.1A
DC Current
40.00 A
0.01A
±(2.5% + 5 digits)
400.0 A
0.1A
±(2.5% + 5 digits)
AC Voltage 50/60Hz TRMS
400.0mV
0.1mV
±(1.5% + 30 digits)
4.000 V
0.001V
±(1.5% + 8 digits)
40.00 V
0.01V
400.0 V
0.1V
600 V
1V
±(2.5% + 5 digits)
DC Voltage
400.0 mV
0.1mV
±(0.8% + 2 digits)
4.000 V
0.001V
±(1.5% + 2 digits)
40.00 V
0.01V
400.0 V
0.1V
600 V
1V
±(2.0% + 2 digits)
Resistance
400.0Ω
0.1Ω
±(1.0% + 4 digits)
4.000kΩ
0.001kΩ
±(1.5% + 2 digits)
40.00kΩ
0.01kΩ
400.0kΩ
0.1kΩ
4.000MΩ
0.001MΩ
±(2.5% + 3 digits)
40.00MΩ
0.01MΩ
±(3.5% + 5 digits)
Capacitance
40.00nF
0.01nF
±(4.0% + 20 digits)
400.0nF
0.1nF
±(3.0% + 5 digits)
4.000µF
0.001µF
40.00µF
0.01µF
100.0µF
0.1µF
±(4.0% + 10 digits)
Frequency
10 to 10kHz
0.01Hz
±(1.5% + 2 digits)
Sensitivity: 100V(<50Hz); 50V(50 to 400Hz); 15V(401Hz to 10kHz)
Duty Cycle
0.5% to 99.0%
0.1%
±(1.2% + 2 digits)
Pulse width: 100s to 100ms, Frequency: 10Hz to 10kHz
Temperature Type K
-4.0 to 1400°F
-20 to 760°C
0.1° <400°
1° >400°
±(3% + 9°F/5°C)
Specification does not include probe accuracy. Range of supplied probe is -22 to 572°F (-30 to 300°C)