- All Products
- Shop by Brands
- BW Technologies
- BW Technologies
- BW Technologies Monitors
- Models
- BW Clip
- BW Clip4
- GasAlertClip Extreme
- GasAlert Extreme
- GasAlertMicroClip XT
- GasAlertMicroClip XL
- GasAlertMicroClip X3
- GasAlertQuattro
- GasAlertMax XT II
- GasAlertMicro 5 Series
- SamplerPak
- IntelliDox Docking System
- MicroDock II
- BW Ultra
- BW Solo
- Gas Monitors
- Gas Monitor Manufacturers
- BW Technologies
- Bacharach
- Biosystems
- Crowcon
- Gas Clip Technologies
- GfG Instruments
- GMI/Detcon
- Honeywell Analytics
- Industrial Scientific
- MSA
- RAE Instruments
- RKI Instruments
- Calibration Gas
- Combustion Analyzers
- Water Quality
- Reliability Instruments
- Refractometers
- HVAC
- Weather
- Temperature
- Laboratory
- Sound
- IAQ
- Electrical
- All Categories
Extech EX830 1000A True RMS AC/DC Clamp Meter with IR Thermometer with NISTL
Item #:
EXT-EX830-NISTL
Brand:
Extech
Share this product:
EX830 1000A True RMS AC/DC Clamp Meter with IR Thermometer with NISTL by Extech
Ideal for industrial applications the 800 series Full size 1000A clamps feature a built-in Infared thermometer and rugged double molded housing
Features
- Non-contact InfraRed Temperature measurements with laser pointer
- Models with True RMS Current and Voltage measurements
- Peak hold captures inrush currents and Transients
- MultiMeter functions include AC/DC Voltage, Resistance, Capacitance, Frequency, Type K Temperature (EX820/EX830), Diode, and Continuity
- 1.7" (43mm) jaw opening for conductors up to 750MCM or two 500MCM
- 4000 count backlit display
- Features include Data Hold and Min/Max
- Autoranging with manual range button
- Auto Power off
- Complete with test leads, 9V battery, general purpose Type K probe (EX820/EX830), and case
- DC/ AC Current
- True RMS
- Type K thermometer
- DC Zero
Clamp jaw opening | 43mm (1.7") approx. |
Display | 3-3/4 digits (4000 counts) backlit LCD |
Continuity check | Threshold 40Ω; Test current < 0.5mA |
Diode test | Test current of 0.3mA typical; Open circuit voltage < 3VDC typical |
Low Battery indication | Battery symbol is displayed |
Over-range indication | 'OL' displayed |
Measurement rate | 2 readings per second, nominal |
PEAK | Captures peaks >1ms |
Thermocouple sensor | Type K thermocouple required |
IR Spectral response | 6 to 16µm |
IR Emissivity | 0.95 fixed |
IR distance ratio | 8:1 |
Input Impedance | 10MΩ (VDC and VAC) |
AC bandwidth | 50 to 400Hz (AAC and VAC) |
AC response | True rms (AAC and VAC) |
Crest Factor | 3.0 in 40A and 400A ranges, 1.4 in 1000A range (50/60Hz and 5% to 100% of range) |
Operating Temperature | 5°C to 40°C (41°F to 104°F) |
Storage Temperature | -20°C to 60°C (-4°F to 140°F) |
Operating Humidity | Max 80% up to 31°C (87°F) decreasing linearly to 50% at 40°C (104°F) |
Storage Humidity | <80% |
Operating Altitude | 2000meters (7000ft) maximum. |
Battery | One (1) 9V Battery (NEDA 1604) |
Auto power OFF | After approx. 25 minutes |
Dimensions & Weight | 270x110x50mm (10.6x4.3x2"); 386g (13.6 oz) |
Safety | For indoor use and in accordance with the requirements for double insulation to IEC1010-1 (2001): EN61010-1 (2001) Overvoltage Category III 600V and Category II 1000V, Pollution Degree 2. |
Patent notice | U.S. Patent 7163336 |
Function |
Range & Resolution |
Accuracy (% of reading + digits) |
AC Current
50/60 Hz |
400.0 AAC |
± (2.5% + 8d) |
1000 AAC |
± (2.8% + 5d) |
|
DC Current |
400.0 ADC |
± (2.5% + 5d) |
1000 ADC |
± (2.8% + 5d) |
|
AC Voltage
50/60Hz |
400.0 mVAC |
± (1.0% + 10d) |
4.000 VAC |
± (1.5% + 5d) |
|
40.00 VAC |
||
400.0 VAC |
||
600 VAC |
± (2.0% + 5d) |
|
DC Voltage |
400.0 mVDC |
± (0.8% + 2d) |
4.000 VDC |
± (1.5% + 2d) |
|
40.00 VDC |
||
400.0 VDC |
||
600 VDC |
± (2.0% + 2d) |
|
Resistance |
400.0Ω |
± (1.0% + 4d) |
4.000kΩ |
± (1.5% + 2d) |
|
40.000kΩ |
||
400.0kΩ |
||
4.000MΩ |
± (2.5% + 3d) |
|
40.00MΩ |
± (3.5% + 5d) |
|
Capacitance |
4.000nF |
± (5.0% + 30d) |
40.00nF |
± (5.0% + 20d) |
|
400.0nF |
± (3.0% + 5d) |
|
4.000µF |
||
40.00µF |
||
400.0µF |
± (4.0% + 10d) |
|
4.000mF |
± (10% + 10d) |
|
40.00mF |
unspecified |
|
Frequency |
4.000kHz |
± (1.5% + 2d) |
Sensitivity: 100V (<50Hz); 50V (50 to 400Hz); 5V (401Hz to 4000Hz) |
||
Temperature
(type-K) |
-4 to 1400°F |
± (3%rdg + 9°F) |
-20 to 760°C |
± (3%rdg + 5°C) |
|
Temp
(IR) |
-58 to -4°F |
± 9°F |
-4 to 518°F |
±2.0% reading or
± 4°F
whichever is > |
|
-50 to -20°C |
±5°C |
|
-20 to 270°C |
±2.0% reading or ±2°C
whichever is > |