- All Products
- Shop by Brands
- BW Technologies
- BW Technologies
- BW Technologies Monitors
- Models
- BW Clip
- BW Clip4
- GasAlertClip Extreme
- GasAlert Extreme
- GasAlertMicroClip XT
- GasAlertMicroClip XL
- GasAlertMicroClip X3
- GasAlertQuattro
- GasAlertMax XT II
- GasAlertMicro 5 Series
- SamplerPak
- IntelliDox Docking System
- MicroDock II
- BW Ultra
- BW Solo
- Gas Monitors
- Gas Monitor Manufacturers
- BW Technologies
- Bacharach
- Biosystems
- Crowcon
- Gas Clip Technologies
- GfG Instruments
- GMI/Detcon
- Honeywell Analytics
- Industrial Scientific
- MSA
- RAE Instruments
- RKI Instruments
- Calibration Gas
- Combustion Analyzers
- Water Quality
- Reliability Instruments
- Refractometers
- HVAC
- Weather
- Temperature
- Laboratory
- Sound
- IAQ
- Electrical
- All Categories
Extech CT80 AFCI, GFCI and AC Circuit Analyzer
Item #:
EXT-CT80
Brand:
Extech
Share this product:
CT80 AFCI, GFCI and AC Circuit Analyzer by Extech
Features
Outlet Tester functions:
- AFCI
- GFCI Trip Current
- GFCI Trip Time
- EPD Trip Current
- Neutral to Ground Voltage
- Hot, Neutral and Ground Impedance
- Open or Reversed wiring
- ASCC (Available Short Circuit Current
AC Load Tester:
- Selectable loads of 12, 15 and 20 Amps
- Measures loaded and unloaded AC Line Voltage
- Calculates and displays % Voltage Drop and Line Impedance
- Displays Peak Line Voltage and Frequency
- Over-Temperature protection
- Complete with AC test cord (standard North American 3-prong plug)
Display | 128 x 64 LED with backlighting |
Voltage display update rate | 2.5 seconds max. |
Over range indication | 'OL' display |
Equipment Power Rating | 100 to 250 VAC 3.9 VA, 45 to 65Hz, 18.0mA |
Operating Temperature | 0°C to 50°C (32°F to 122°F) |
Storage Temperature | 0°C to 50°C (32°F to 122°F) |
Operating Humidity | Max 80% |
Storage Humidity | Max 80% |
Case construction | ABS UL 94V/0/5VA rated |
Altitude | 2000m (6561.7 ft) |
Dimensions | 203 x 71 x 51 mm (8 x 2.8 x 2") |
Weight | 317.5g (11.2 oz.) |
Safety approvals | CE, ETL |
General safety | For indoor use and in accordance with the requirements for double insulation to IEC1010-1 (2001): EN61010-1 (2001) Overvoltage Category II 300V Pollution Degree 2. |
Range and Resolution |
Accuracy |
|
Line Voltage |
85.0 to 250.0 VAC |
± (1.0% + 0.2V) |
Peak Line Voltage |
121.0 to 354.0 VAC |
± (1.0% + 0.2V) |
Frequency |
45.0 to 65.0 Hz |
± (1.0% + 0.2Hz) |
Voltage drop (%) |
0.1 to 99.9% |
± (2.5% + 0.2%) |
Voltage (under load) |
10.0 to 250.0 VAC |
± (2.5% + 0.2V) |
Neutral to Ground Voltage |
0.0 to 10.0 VAC |
± (2.5% + 0.2V) |
Impedance |
0.00 to 3.00 Ω (Hot) |
± (2.5% + 0.02Ω) |
>3 Ω (Neutral, Ground) |
Unspecified |
|
GFCI Trip Time |
1ms to 6.500 Seconds |
± (1.0% + 2ms) |
GFCI Trip Current |
6.0 to 9.0mA |
± (1.0% + 0.2mA) |
EPD Trip Current |
30.0 to 37.0mA |
± (1.0% + 0.2mA) |
AFCI Test Current Pulses |
8 to 12 pulses (106 to 141 amps each) |
|
AFCI Test Time |
0.5 seconds total (each pulse 8.3ms max.) |