- All Products
- Shop by Brands
- BW Technologies
- BW Technologies
- BW Technologies Monitors
- Models
- BW Clip
- BW Clip4
- GasAlertClip Extreme
- GasAlert Extreme
- GasAlertMicroClip XT
- GasAlertMicroClip XL
- GasAlertMicroClip X3
- GasAlertQuattro
- GasAlertMax XT II
- GasAlertMicro 5 Series
- SamplerPak
- IntelliDox Docking System
- MicroDock II
- BW Ultra
- BW Solo
- Gas Monitors
- Gas Monitor Manufacturers
- BW Technologies
- Bacharach
- Biosystems
- Crowcon
- Gas Clip Technologies
- GfG Instruments
- GMI/Detcon
- Honeywell Analytics
- Industrial Scientific
- MSA
- RAE Instruments
- RKI Instruments
- Calibration Gas
- Combustion Analyzers
- Water Quality
- Reliability Instruments
- Refractometers
- HVAC
- Weather
- Temperature
- Laboratory
- Sound
- IAQ
- Electrical
- All Categories
Extech 382100 1200A 3-Phase Power Analyzer/Datalogger
Item #:
EXT-382100
Brand:
Extech
Share this product:
382100 1200A 3-Phase Power Analyzer/Datalogger by Extech
Features
- Large dot-matrix, sun-readable, numerical, backlit LCD
- Full system analysis with up to 35 parameters: V (phase-to-phase), V (phase-to-ground); A (phase-to-ground); KW / KVA / KVAR / PF (phase); KW / KVA / KVAR / PF (system); KWH / KVAH / KVARH / PFH (system); Phase angle
- High accuracy autoranging current clamps (0.2A to 1200A)
- 600.0VAC input with CAT III-600V safety rating
- Adjustable Current Transformer (CT) and Potential Transformer (PT) ratio for high power distribution systems
- Log up to 30,000 reading on a removable SD memory card in Microsoft Excel® format
- Wide sampling rate range (2 seconds to 2 hours)
- Captured measurements can be imported directly into Excel via the SD memory card
- Easy-to-use onscreen menu
- Easy-to-grab rugged over molded housing
Applications
- AC Power Quality Evaluation
- Motor/Generator Installation
- Energy Audits
Circuit | Custom one-chip microprocessor LSI circuit | |
Display | LCD Size: 81.4 X 61 mm (3.2 X 2.4") Dot Matrix backlit LCD (320 X 240 pixels) |
|
Measurements | ACV / ACA / AC Watts (True Power); AC Watts (Apparent Power); AC Watts (Reactive Power); Power factor; Phase angle; Frequency | |
Wire connections | 1P/2W, 1P/3W, 3P/3W, 3P/4W | |
Voltage ranges | 10 ACV to 600 ACV (Auto Range) | |
Current ranges | 0.2 ACA to 1200 ACA (Auto / Manual Range) | |
Safety standard | IEC1010 CAT III 600 V | |
ACV input impedance | 10M ohms | |
Range select | ACV | Auto Range |
ACA | Auto / Manual Range | |
Clamp frequency response | 40 Hz to 1 KHz | |
Tested frequency | 45 to 65 Hz | |
Over load protection | ACV | 720 ACV RMS |
ACA | 1300 ACA with clamp probe | |
Over-range indicator | "OL" | |
Under-range indicator | "UR" | |
Data Hold | Freezes displayed reading | |
Data Recording | SD memory card | |
Sampling Time | Approx. 1 second | |
Datalogger | Real time data logger saves data to SD memory card for download to PC (data file opens directly to spreadsheet) | |
Sampling rate: 2 seconds to 7200 seconds | ||
Data Output | Serial or USB connection (cable supplied) | |
Operating Temp. | 0 to 50o C (0 to 122o F) | |
Operating R.H. | 80% Relative Humidity max. | |
Power Supply | Eight (8) 'AA' 1.5VDC batteries or AC - DC 9V power adapter | |
Power Consumption | Meter: 300 mA DC; Clamp: 20 mA DC | |
Max. Conductor size | Clamp can accommodate up to 86 mm (3.4" ) diameter | |
Weight | Meter: 1049g (2.3 lbs.) (with batteries); Clamp: 522g (1.2 lbs) | |
Dimensions | Meter: 225 X 125 X 64 mm (8.86 X 4.92 X 2.52") | |
Clamp: 210 X 64 X 33mm (8.3 X 2.5 X 1.3") | ||
Clamp Jaw: 86 mm (3.4") | ||
Accessories Included | Instruction manual; Test Leads: 1 Set (4 pieces); Alligator clips: 1 Set (4 pieces); Clamp Probe (3); AC to DC 9V adapter; SD card (2G); Carrying case |