Features

  • Three models provide high Accuracy and Resolution
  • Large 4000 count LCD display with full function indication
  • Fast 40 segment analog bargraph
  • One touch "Auto Zero" for DCA measurements eliminates the need to turn a knob to zero adjust
  • Measure current draw when conducting energy usage audits
  • Data hold, Max/Min recall display
  • 0.9" (23mm) clamp jaw opening
  • Overload protection to 400A DC
  • True RMS models recommended for measurements where distortion may otherwise cause inaccuracies
  • Optional 3-prong AC Line Separator enables safe and easy measurements on power cables with molded plugs (splits hot conductor from neutral and ground)
General Specifications
Display 3-3/4 digit (4032 count) LCD with 40 segment bargraph
Functions ACA, DCA, ACV, DCV, Resistance, Frequency, Continuity
Polarity "-" indicates negative polarity
Current sensor Hall effect sensor type
Overload OL
DCA zero adjust One-touch zero key
Display rate 3 readings/second (30 readings/second for bargraph)
Battery Two 1.5V AA batteries
Operating temperature -10°C to 50°C (4°F to 122°F)
Operating humidity < 85% RH
Power consumption Approximately 17mA DC
Sampling time 3 times/sec (display); 30 times/sec (bargraph)
Weight 225g (8 oz.) including battery
Dimensions 183 x 63.6 x 35.6mm (7.2 x 2.5 x 1.4") (HWD)
Jaw opening 23mm (0.9")
Standards IEC 1010 Category III 300V, Category II 600V

Range Specifications
Function
Range
Resolution
Accuracy
Overload protect
DC Current
40A
10mA
±(1.0% +2dgts)
400A DC
0 to 150A
100mA
±(1.0% +2dgts)
400A DC
150 to 200A
100mA
±(2.2% +2dgts)
400A DC
AC Current
50/60Hz
40 to 400Hz
40A
10mA
±(1.0% +3dgts)
±(1.5% +4dgts)
400A DC
0 to 150A
100mA
±(1.0% +3dgts)
±(1.5% +4dgts)
400A DC
150 to 200A
100mA
±(2.2% +3dgts)
±(2.5% ±4dgts)
400A DC
DC Voltage
400V
0.1V
±(1.0% +2dgts)
1000VDC
AC Voltage
50/60Hz
40 to 400Hz
400V
0.1V
±(1.5% +2dgts)
±(2.0% +4dgts)
800V AC
Resistance
40 to 400Ω
0.1Ω
±(1.0% +2dgts)
Beeper <approx 38Ω
600V AC
Frequency
1 to 100k
0.001-100
±0.5% ±2dgts
Sensitivity; 10VAC
600V AC