1-866-4 JJSTECH(1-866-455-7832)

Bacharach 3015-4790 (IATA) PGM-IR N20 Monitor

Item #:
3015-4790
Brand:
Bacharach
Bacharach 3015-4790 (IATA) PGM-IR N20 Monitor
$7,159.10
Qty
Send This Page to a Friend

Ask an Expert

Our tech experts are ready to help!

1-866-4 JJSTECH (1-866-455-7832)

Email Us
Share this product:
Bacharach 3015-4790 (IATA) PGM-IR N20 Monitor

Bacharach 3015-4790 (IATA) PGM-IR N20 Monitor

$7,159.10

3015-4790 (IATA) PGM-IR N20 Monitor by Bacharach

The PGM-IR is an advanced portable monitor that uses long-life non-dispersive infrared (NDIR) sensor technology for analyzing and checking low-level gas leaks. With very fast response and clearing times, the unit can identify and pinpoint very small levels of refrigerants, nitrous oxide or carbon dioxide gas in ambient air, showing real-time concentrations in either parts per million (ppm) or elapsed time weighted average (TWA) with a resolution down to 1 ppm.

The unit self-calibrates in 4 minute intervals by drawing ambient air through its filter to provide a good "zero" baseline, enabling the monitor to be used in contaminated environments without affecting the readings of the target gas. Additional features include datalogging of up to 200 readings, and a leak check mode with "tick-rate" audible / visual alarms. The PGM-IR's probe helps to locate leaks in small or hard to reach places and provides up to 12 hours operation on a fully charged battery.

Features & Benefits:

  • Long-life, Non-Dispersive Infrared (NDIR) sensor allows for precision low-level leak detection
  • Detection and measurement of CFC, HFC and HCFC refrigerants, as well as CO2, N2O and SF6 gases
  • Locates leaks in contaminated or high-ventilation areas - immune to changes in temperature and humidity
  • Cut leak inspection times by 50%
  • Instrument comes with battery pack, probe, charger and soft case with shoulder strap
  • LCD screen displays real-time gas concentrations with an audible tick-rate to pinpoint source of leaks
  • Locate leaks within display cases where traditional leak detectors cannot
  • Applications include refrigerant gas detection, trace gas analysis and medical monitoring

Includes:

  • Rechargeable battery pack
  • 120 VAC charging adapter
  • Soft case
Gas Library
CFC R-11, R-12, R-113, R-114, R-502, HFP
HFC R-404a (HP62), R-407a, R-407c (AC9000), R-134a, R-410a (AZ20), R-507 (AZ50), R-508b (SUVA95), R236FA, R125, R245Fa, R422a, R422d, R427a, R424a, R426a and R438a, R407F
HCFC R-22, R-123, R-124, R-500, R-503, R-401a (MP39), R-402a (HP80), R-402b (HP81), R-408a, R-409a, R-23, R21, R227
HALON H1301,H2402, H1211
Other FA188, FC72, N1230, H1234YF, H1234ZE, N7000, N7200, N7300, N7600
Measuring Range All gases 0 to 10,000 ppm
Warm-Up Time 5 minutes (300 seconds)
Detector Type Infrared, Non-Dispersive
Sensitivity 1 ppm
Accuracy ±1 ppm ±10% of reading from 0-1000 ppm (For R11, R22, R113: ±10 ppm ±15% of reading from 0-1000 ppm)
Response Time 90% of response within 5 seconds; 100% in 7 seconds
Temperature Drift 1.5 ppm per °C between purge cycles
System Noise .Less than 40dB (A) at 10 ft (3 m)
Operating Temperature 32 to 122°F (0 to 50°C)
Ambient Humidity 5 to 90% RH (non-condensing)
Altitude Limit 6,562 ft (2,000 m)
Power DC power pack, provides 8 -12 hours of operation
Power Consumption 15 Watts maximum
Front panel 3 indicator lights
ON: Green LED flashes during warm-up, then glows steadily during normal operation
FAULT: Yellow LED flashes when there is a system fault
ALARM: Red LED flashes when the gas level is above its alarm setting
Audible Alarm Internal audible alarm programmable for any of the following conditions: OFF, FAULT/ALARM, ALARM
Dimensions (D x L x W) 9.0 x 14.5 x 5.0 inches (229 x 368 x 127 mm)
Weight Less than 9 lbs (4 kg) including battery
Valid Calibration Period to Specifications 12 months
Warranty 2 years from date of shipment