- All Products
- Shop by Brands
- BW Technologies
- BW Technologies
- BW Technologies Monitors
- Models
- BW Clip
- BW Clip4
- GasAlertClip Extreme
- GasAlert Extreme
- GasAlertMicroClip XT
- GasAlertMicroClip XL
- GasAlertMicroClip X3
- GasAlertQuattro
- GasAlertMax XT II
- GasAlertMicro 5 Series
- SamplerPak
- IntelliDox Docking System
- MicroDock II
- BW Ultra
- BW Solo
- Gas Monitors
- Gas Monitor Manufacturers
- BW Technologies
- Bacharach
- Biosystems
- Crowcon
- Gas Clip Technologies
- GfG Instruments
- GMI/Detcon
- Honeywell Analytics
- Industrial Scientific
- MSA
- RAE Instruments
- RKI Instruments
- Calibration Gas
- Combustion Analyzers
- Water Quality
- Reliability Instruments
- Refractometers
- HVAC
- Weather
- Temperature
- Laboratory
- Sound
- IAQ
- Electrical
- All Categories
GfG EC 28 Gas Transmitter with Ethylene Oxide (C2H4O), 0 - 20.0 ppm, Display / Modbus - 2811-713-007
Item #:
2811-713-007
Brand:
GfG
Share this product:
2811-713-007 EC 28 Gas Transmitter with Ethylene Oxide (C2H4O), 0 - 20.0 ppm, Display / Modbus by GfG
Advanced Technology
Wherever hazards are expected, the EC 28 transmitter and GfG's proven monitoring systems are the right choice for reliable surveillance. The ATEX-certified design, an integrated, Ex-proof buzzer, and bright alarm LEDs provide the highest safety in hazardous areas by including visual and audible alarms. The gas alarm not only alerts the person in the control room of hazards, but also the person on-site.
Easy handling
Smart sensor technology allows a user to install the transmitter or to replace a sensor within a few seconds – just plug the sensor into the transmitter. Adjustments are done directly at the transmitter using touch keys or with the remote control (one-person calibration).
Remote Control RC2
Ammonia and hydrogen are lighter than air. With the transmitter installed close to the ceiling, GfG can provide permanently connected cables with plugs for the remote control, which allow the user to do all adjustments without having to climb a ladder. In addition, one remote control can be used for several transmitters, which helps cut costs and increase efficiency.
The remote control display is always identical to that of the transmitter, making inspection, service, and calibration considerably simple.
The remote control reads the current gas concentration and can be used as an external display.
Integrated Alarm – Saves Money on Ex-proof Alarm and Wiring!
The EC 28 D model shows the current gas concentration on-site at the display of the transmitter and also at GfG’s GMA controller.
The EC 28 DAprovides additional bright alarm LEDs and a buzzer – avoiding costs for a separate Ex-proof horn and an Ex-proof light. You also save money on wiring to connect the controller and alarm devices.
In combination with GfG's flexible control units, the EC 28 provides various possibilities for reliable and cost-effective gas monitoring.
Reliable Measurement, Increased Safety, Minimized Cost of Operation
Accurate sensors and integrated temperature compensation provide the highest measurement accuracy. Low maintenance requirements and the long sensor life reduce your cost of ownership.
Features
- Reading of gas concentration at transmitter display
- Ex-proof visual and audible alarms
- ATEX certificate II 1 G EEx ia IIC T4 / II 2 G EEx em [ib] IIC T4
- One-person calibration at transmitter using touch keys or remote control
- Plug-in smart sensor – sensor replacement without opening the casing
Advantages
- Concentration display at transmitter or at remote control
- ATEX II 1 G EEx ia IIC T4 / II 2 G EEx dem [ib] IIC T4
- Ex-proof visual and audible alarms
- No need for expensive Ex-proof buzzer or wiring
- Easy sensor replacement by means of plug-in smart sensors
- Long sensor life
- Low service requirement
- Permanent status and function display at transmitter
- Adjustments without opening the casing using touch keys or remote control; easy handling even for hardto-reach transmitter positions
Detection principle | Electrochemical |
Ambient temperature | -4 to +122ºF / -20 to +50ºC |
Output signal | 4 – 20 mA |
Supply voltage | 15 –30 V DC |
Weight | 28.22 ounces (800 grams) with display |
Dimensions | 7.63x3.94x2.17 inches (193x100x55 mm) (HxWxD) |
Casing protection | IP 64 |
ATEX Labelling | II 1 G EEx ia IIC T4 and
II 2 G EEx em [ib] IIC T4 0158 |
Transmitter cable | Shielded cable 2/3/6 x 0.75mm2 M 16 x 1.5 |
Display | 4-digit LCD for linearized measurement values and messages, service, LEDs for operation / fault |
Touch keys | 3 keys for all adjustments/calibration, function test |
Options | Intrinsically safe (EC28 I, EC28 DI) 1 relay (EC28 DAR) |
Gase | Range |
Ammonia (NH3) | 0-200, 0-500, 0-1,000 |
Carbon monoxide (CO) | 0-500, 0-2,000 |
Chlorine (Cl2) | 0-50, 0-250 |
Chlorine dioxide (ClO2) | 0-2 |
Hydrogen (H2) | 0-2,000, 0-1% volume, 0-4% volume |
Hydrogen chloride (HCl) | 0-30, 0-200 |
Hydrogen cyanide (HCN) | 0-50, 0-200 |
Ethylene oxide (C2H4O) | 0-100 |
Hydrogen fluoride (HF) | 0-10 |
Hydrogen sulfide (H2S) | 0-200, 0-1,000 |
Nitrogen dioxide (NO2) | 0-50, 0-200 |
Nitrogen monoxide (NO) | 0-300, 0-1,500 |
Oxygen (02) | 0-25% volume |
Ozone (O3) | 0-1, 0-5 |
Phosgene (COCl2) | 0-2 |
Sulfur dioxide (SO2) | 0-50, 0-500 |
Silan (SiH4) | 0-50 |